• 제목/요약/키워드: Direct Normal Insolation

검색결과 19건 처리시간 0.027초

법선면 직달일사량 예측기법을 이용한 한반도에서의 태양열발전단지 건설을 위한 최적지 선정에 관한 연구 (A Study on the Estimating Direct Normal Insolation Using Horizontal Global Insolation for Solar Thermal Generation System Installation in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.77-87
    • /
    • 2012
  • Images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. For the validation, estimated direct normal Insolation is compared with observed direct normal Insolation at 16 sites over the Korean peninsular from January 1982 to December 2010. Estimated direct normal Insolation shows reliable results with average deviation of -5.4 to +5.9% from the measured values and the yearly averaged direct normal Insolation of Korean peninsula was turned out to be 2.93 $kW/m^2/day$.

국내 태양열발전단지 건설을 위한 법선면 직달일사량 자원조사 (A Survey of Direct Normal Insolation Resources for the Construction of Solar Thermal Power Generation Sites in Korea)

  • 조덕기;강용혁;오정무
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.11-18
    • /
    • 2005
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research's new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $5.4kWh/m^2/day$ of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were $5.53kWh/m^2/day$ and $5.84kWh/m^2/day$, and for fall and winter their values were $5.3kWh/m^2/day$ and $4.94kWh/m^2/day$ respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

국내 고집광 태양에너지 발전단지 건설을 위한 법선면 직달일사량 자원조사 (A Survey of Direct Normal Insolation Resources for the Construction of Solar Concentrating Power Generation Sites in Korea)

  • 조덕기;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.209-214
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean 2.67 kWh/$m^2$/day of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were 2.91 kWh/$m^2$/day and 2.23 kWh/$m^2$/day, and for fall and winter their values were 2.78 kWh/$m^2$/day and 2.77 kWh/$m^2$/day respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value

  • PDF

국내 직달일사량 자원 분석 (Analysis of Direct Normal Insolation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.130.1-130.1
    • /
    • 2011
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67kWh/m^2/day$ of the all day's direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91kWh/m^2/day$ and $2.23kWh/m^2/day$, and for fall and winter their values were $2.78kWh/m^2/day$ and $2.77kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

  • PDF

국내 법선면 직달일사량 자원조사 (전일 분석을 중심으로) (A Survey of Direct Normal Insolation Resources in Korea (Focused on All days Analysis))

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.51-56
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67\;kWh/m^2/day$ of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91\;kWh/m^2/day$ and $2.23\;kWHm^2/day$, and for fall and winter their values were $2.78\;kWh/m^2/day$ and $2.77\;kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

국내 태양복사에너지 자원의 재평가 (Revaluation of Solar Radiation Energy Resources in Korea)

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.15-21
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.60 kWh/$m^2$/day and the yearly mean 2.62 kWh/$m^2$/day of the direct normal insolation was evaluated for all days.

실측에 의한 국내 법선면 직달일사량 자원의 재평가 (A Revaluation of Direct Normal Insolation Data by Field Measurement in Korea)

  • 조덕기;전일수;이순명;이태규;강용혁;오정무
    • 태양에너지
    • /
    • 제20권2호
    • /
    • pp.31-42
    • /
    • 2000
  • Since the direct normal insolation is a main factor for designing any focusing solar system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $4,576kcal/m^2.day$ of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were $4,710kcal/m^2.day$ and $4,960kcal/m^2.day$, and for fall and winter their values were $4,484kcal/m^2.day$ and $4,151kcal/m^2.day$ respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

  • PDF

국내 태양열발전시스템 설치를 위한 법선면 직달일사량 분석 (Evaluation of Direct Normal Radiation Resources for Construction of Solar Thermal Power System in Korea)

  • 조덕기;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.653-657
    • /
    • 2007
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research's new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean 5.41kWh/$m^2$/day of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were 5.54kWh/$m^2$/day and 5.86kWh/$m^2$/day, and for fall and winter their values were 5.32kWh/$m^2$/day and 4.92kWh/$m^2$/day respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

  • PDF

국내 일사량 자원 특성분석 (A Characteristic Analysis of Solar Radiation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.61 kWh/$m^2$/day and the yearly mean 5.38 kWh/$m^2$/day of the direct normal insolation was evaluated for clear days.

  • PDF

국내 태양광자원의 경년변화 (A Change of Yearly Solar Radiation Energy Resources in Korea)

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.81-86
    • /
    • 2010
  • Since the solar energy resource is the main input for sizing any solar photovoltaic system and solar thermal power system, it is essential to utilize the solar radiation data as a application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations in Korea. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. From the results, the yearly averaged horizontal global insolation was turned out 3.60kWh/$m^2$/day and a significant difference of horizontal global insolation is observed between 1982~1990 and 1991~1999, 2000~2008 through 16 different cities in Korea.