• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.03 seconds

Evaluation of Modeling Approach for Suspended Sediment Yield Reduction by Surface Cover Material using Rice Straw at Upland Field (모델링 기법을 이용한 밭의 볏짚 지표피복의 부유사량 저감효과 평가 방법)

  • Park, Youn Shik;Kum, Donghyuk;Lee, Dong Jun;Choi, Joongdae;Lim, Kyoung Jae;Kim, Ki-sung
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.1
    • /
    • pp.108-114
    • /
    • 2016
  • Sediment-laden water leads to water quality degradation in streams; therefore, best management practices must be implemented in the source area to control nonpoint source pollution. Field monitoring was implemented to measure precipitation, direct runoff, and sediment concentrations at a control plot and straw-applied plot to examine the effect on sediment reduction in this study. A hydrology model, which employs Curve Number (CN) to estimate direct runoff and the Universal Soil Loss Equation to estimate soil loss, was selected. Twenty-five storm events from October 2010 to July 2012 were observed at the control plot, and 14 storm events from April 2011 to July 2011 at the straw-applied plot. CN was calibrated for direct runoff, and the Nash-Sutcliffe efficiency and coefficient of determination were 0.66 and 0.68 at the control plot. Direct runoff at the straw-applied plot was calibrated using the percentage direct runoff reduction. The estimated reduction in sediment load by direct runoff reduction calibration alone was acceptable. Therefore, direct runoff-sediment load behaviors in a hydrology model should be considered to estimate sediment load and the reduction thereof.

Experimental Study on the Direct Contact Thermal Screw Drying of Sawdust for Wood-Pellet Fuel

  • Lee, Hyoung-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.23-28
    • /
    • 2007
  • Wood fuel must be dried before combustion to minimize the energy loss. Sawdust of Japanese red pine was dried in a direct contact thermal screw dryer to investigate the drying characteristics of sawdust as a raw material for bio-fuel. Average drying rate and energy efficiency was 1.4%/min and 69.23% at $100^{\circ}C$, respectively, and those at $120^{\circ}C$ was 2.1%/min and 71.03%, respectively.

Modification of Cotton Treated with Cellulase( I ) ―Effect of Treating Condition on the Weight Loss― (셀룰라아제 처리에 의한 면의 개질( I ) ―감량률에 미치는 처리조건의 영향―)

  • Hong, Ki Jeong;Lee, Mun Cheul;Bae, So Yeung;Park, Soo Min;Kim, Kyung Hwan
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.10-19
    • /
    • 1993
  • Broad, mercerized broad, mercerized twill cotton fabrics and rayon fabric were treated with cellulase for 30~480 minutes at different temperature, concentration, time, and also treating methods such as continuously-treated or repeatedly-treated, and dyed with two direct dyes before or after enzyme treatment. From the experimental result by treating under the various conditions above, it was obtained that the weight loss increased more in thin fabric than thick one. In addition, it was considered that the treatment in 5$0^{\circ}C$ for 240 minutes brought about the ideal weight loss and flexible hand of the specimens. For both broad and mercerized broad, repeated treatment showed more weight loss than continuous. Direct dye on cotton fabric apparently inhibited hydrolysis. Ionic surfactants showed the inhibition effect of the catalytic hydrolysis of enzyme, on the other hand, nonionic surfactant did not.

  • PDF

Earthquake Loss Estimation Including Regional Characteristics (지역특성을 반영한 지진손실평가)

  • Kim, Joon-Hyung;Hong, Yun-Su;Yu, Eunjong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.311-320
    • /
    • 2023
  • When an earthquake occurs, the severity of damage is determined by natural factors such as the magnitude of the earthquake, the epicenter distance, soil properties, and type of the structures in the affected area, as well as the socio-economic factors such as the population, disaster prevention measures, and economic power of the community. This study evaluated the direct economic loss due to building damage and the community's recovery ability. Building damage was estimated using fragility functions due to the design earthquake by the seismic design code. The usage of the building was determined from the information in the building registrar. Direct economic loss was evaluated using the standard unit price and estimated building damage. The standard unit price was obtained from the Korean Real Estate Board. The community's recovery capacity was calculated using nine indicators selected from regional statistical data. After appropriate normalization and factor analysis, the recovery ability score was calculated through relative evaluation with neighboring cities.

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

  • Hossam H. Abdellatif;Palash K. Bhowmik;David Arcilesi;Piyush Sabharwall
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2375-2387
    • /
    • 2024
  • The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

Development of a Rice Seed Pelleting Machine for Direct Seeding in Rice Cultivation (직파용 벼 펠렛종자 제조장치 개발)

  • 박종수;유수남;최영수;유대성
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.381-390
    • /
    • 2002
  • Direct seeding of rice-seed pellets is expected to be an alternative for solving problems in current direct seeding cultivation of rice. but mass production of rice-seed pellets is prerequisite for practical application. Design. construction and performance evaluation of an experimental rice seed pelleting machine were carried out for mass production of rice-seed pellets. The pelleting machine intended to make a ball type rice-seed pellet, which have 3∼5 rice seeds and diameter of which is 12 mm. Pellet materials ; rice seeds, soil, and binder were mixed and kneaded by the mixer. The designed rice seed pelleting machine fed pellet materials by screw conveyor to forming rolls and made rice-seed pellets. Capacity, ratio of perfect rice-seed pellets, seed and pellet material loss were investigated as mixing ratio of soil to rice seed and feeding rate of pellet materials. The pelleting machine showed up to 37,000 pellets/h of pelleting rate, 61∼71% of weight ratio of perfect rice-seed pellets to pellet materials supplied, 17∼48% of seed loss ratio. Average weight and average diameter of the pellets were 1.66 g and 12.0 mm. respectively. More than 3 rice seeds were included in most pellets at 6 : 1 of mixing ratio of soil to rice seed. And compression strength of the pellets was in the range of 88-130 N. To improve performance of the pelleting machine, improvements of the forming rolls, feeding mechanism, and discharging mechanism for reducing loss of pellet materials and seeds damage are needed.

Assessment of Soil Loss in Irrigation Reservoir based on GIS (GIS를 이용한 관개용 저수지의 토사유실량 산정에 관한 연구)

  • Park, Woo Sik;Hong, Soon Heon;Ahn, Chang Hwan;Choi, Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_1
    • /
    • pp.439-446
    • /
    • 2013
  • This paper is about assessment of soil loss in irrigation reservoir based on GIS. Natural disaster caused by soil loss whose natural incidence has been rapidly reduced due to successful tree planting campaign shows high potential risk, since the latest localized heavy rain resulted from extreme weather event and artificial land development acts as direct factors for land disaster. To prevent it, various techniques and technologies have been used to predict effect of soil loss. However, reliability of techniques and technologies to predict its effect precisely is relatively low so far because the natural disaster by soil loss is taken place by complicated interaction between possible factors and direct factors. Geospatial approach is essential to examine these interactions. In this regard, this study will provide detailed plan to improve prediction reliability for soil loss of irrigation reservoir, using GIS that has Hydrologic -Topographical parameter and digital map as its input parameters.

An Offer of a Procedure Calculating Hourly Rainfall Excess by Use of Horton Infiltration Model in a Basin (유역 단위 Horton 침투모형을 적용한 시간단위 초과우량 산출 절차 제시)

  • Yoo, Ju-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.6
    • /
    • pp.533-541
    • /
    • 2010
  • It is basic for a flood prediction to calculate direct runoff from rainfall in a basin by the rainfall-runoff model. The direct runoff is calculated from rainfall excess or effective rainfall based on a rainfall-runoff model. The total rainfall minus rainfall loss equals rainfall excess with time. This loss can be treated equal to an infiltration loss under the assumption that the infiltration is a major one among the losses in the rainfall-runoff model. Practically obtaining the infiltration loss $\Phi$ index method, W index method or modified ones of these have been used. In this study it is assumed the loss of rainfall in a basin be a well-known Horton infiltration mechanism. And in case that the parameter set is given in the Horton infiltration model a procedure and assumption for calculating hourly infiltration loss and rainfall excess are offered and the results of its application are compared with those of $\Phi$ index method. By this study it is well shown the value of Horton infiltration function is exponentially decay with time as the Horton infiltration mechanism.

A Study on the Predictive Model of Propagation Path Loss in Millimeter-Wave Band (밀리미터파 대역에서 전파경로손실 예측 모델)

  • Kim, Song-Min
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.2
    • /
    • pp.23-28
    • /
    • 2005
  • This study was to suggest the propagation path loss and predictive model of propagation path analysis in order to apply the frequency in the millimeter-wave band to the real time inter-vehicle communication system. This study was to suppose the case of inter-vehicle communication on the one-way two-lanes road in the big cites with a lot of traffic jams in order to analyze the effect by the reflected wave of multipath. As a simulation of suggested model, it found out that the propagation path by the reflected wave was about 0.1[m]$\sim$5.1[m] longer than the one by the direct wave during the transmission of 100[m] wave direct path. Also, as a result of comparing the propagation path loss, the loss would be about -0.8[dB]$\sim$-4.2[dB] larger in case of wall reflection and -0.8[dB]$\sim$-1[dB] vehicle reflection. From the result above, this researcher found out that the path loss of reflected wave produced by the walls was about -3.2[dB] larger than the path loss produced by the adjacent vehicles.

Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss (자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가)

  • Lee, S.;Park, S.H.;Kim, W.S.;Lee, J.K.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.