• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.029 seconds

An Assemble and Expandable Substrate Heating Apparatus for the Semiconductor Manufacturing (조립과 확장이 가능한 반도체 제조용 기판 가열 장치)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.67-71
    • /
    • 2009
  • This research is a new structure of the semiconductor substrate heating apparatus in which the assembly and expansion are possible. The fast thermo-responsive according to the direct heating structure of the heating plate layer adhering closely to the floor side of a substrate and the fast heat loss minimization can be accomplished. Moreover, the contact area of the sheath heater, which is the heating plate layer built-in heating apparatus, is increased, so that it has more heating valid area. There is no problem with the deformation interpreted in the state where it assembles the block of a several of the simulation result structure, the safety, and the stress. In addition, it is confirmed that building a large-size heating block is possible since the temperature deflection of the manufactured plate is lower than the standard value.

A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance

  • Park, Joon Hyung;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.511-517
    • /
    • 2015
  • Determination of the required reserve capacity has an important function in operation of power system and it is calculated based on the largest loss of supply. However, conventional method cannot be applied in future power system, because potential grid-connected distributed generator and abnormal temperature cause the large load imbalance. Therefore this paper address new framework for determining the optimal required reserve capacity taking into account the real time load imbalance. At first, we introduce the way of operating reserve resources which are the secondary, tertiary, Direct Load Control (DLC) and Load shedding reserves to make up the load imbalance. Then, the formulated problem can be solved by the Probabilistic Dynamic Programming (PDP) method. In case study, we divide two cases for comparing the cost function between the conventional method and the proposed method.

급속 조형을 위한 STEP파일의 다이렉트 슬라이싱에 관한 연구

  • 김영한;최홍태;이석희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.898-902
    • /
    • 1995
  • STEP is a neutral model for exchanging CAD modelbetween different CAD systms. The paper presents a laser path contour generation for rapid prototyping originated form STEP format files without using any tools nor libraries for STEP data manipulation. Polygons are generated from every point on the layer of given thickness, which are the intersections of layer plane and edges stored in entity tables. Curves are approximated with polygons whitin segment tolerance limit in order to cover sculptured surfaces. With the advantage of less data loss in direct slicing over STL formats, the system developed in this work shows a good potential to provide data share with various CAD systems including RP data preparation.

  • PDF

A Directly Coupled Log Periodic Microstrip Antenna for X-band (X-band용 직결합 대수주기형 마이크로스트립 안테나)

  • 임규재;고성선;윤현보
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.2
    • /
    • pp.182-191
    • /
    • 1988
  • A log periodic microstrip array antenna using direct coupling feeder is designed at the frequency 7.2-12.4GHz. Transmission line analysis method was used for the design of each antenna element in consideration of the effects of dielectric and conductor loss and the discontinuity, also the optimized feeding points were obtained for the impedance matching between a main transmission line and each antenna element. It is shown that the measured VSWR was less that 2.4 at the frequency 7.2-12.4GHz, and 53% bandwidth was achived.

  • PDF

Resynchronization of Modified JPEG Using a Power Allocation Scheme in a Direct Sequence CDMA System

  • Yim, Choon-Sik;Roh, Jae-Sung;Choi, Eun-Suk;Baek, Joong-Hwan;Cho, Sung-Joon
    • ETRI Journal
    • /
    • v.24 no.5
    • /
    • pp.405-408
    • /
    • 2002
  • In this paper, we discuss recovery schemes for errors occurring when image data encoded with variable length coding (VLC) is transmitted through additive white Gaussian noise (AWGN) and multiple-access interference in direct sequence code division multiple access (DS/CDMA) systems. VLC such as JPEG is so sensitive to channel errors that severe degradation in decoded images occurs even if only one or two bits have errors. This is due to the loss of synchronization at the image decoder. We propose a resynchronization scheme using a power allocation method in wireless DS/CDMA transmission. Through simulation, we know that the proposed method has a more robust resynchronization capability and higher objective and subjective quality than the conventional method.

  • PDF

Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit (카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Synthesis and Properties of Polybenzoxazole Copolymers Having Non Linear Units

  • Han, So Hee;Lee, Eung Jae;Choi, Jae Kon
    • Elastomers and Composites
    • /
    • v.54 no.4
    • /
    • pp.321-329
    • /
    • 2019
  • A series of poly(hyroxyamide)s (PHAs) was prepared by direct polycondensation reaction of 4,4'-(2,3-pyridinedioxy)dibenzoic acid and/or isophthalic acid with 3,3'-dihydroxybenzidine. The yield percentages of the products were high, and the inherent viscosities of the polymer in DMAc solution at 35℃ were 0.31-0.59 dL/g. All PHA polymers were found to be soluble in polar aprotic solvents such as DMAc, DMSO, NMP, and DMF. On the other hand, LiCl was required to dissolve IPHA-1 in aprotic solvents. Poly(benzoxazole)s (PBOs) were partially soluble in conc-H2SO4; IPBO-4, -5, and -6 were partially soluble in NMP only when LiCl was added to the solution, and the solution was heated. The PBO polymers showed a maximum weight loss in the temperature range of 654-680℃, and the char yields at 900℃ under nitrogen atmosphere exceeded 63%.

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF

Effect of Dry Process on Dielectric Properties of PZT Thin Films Prepared by Sol-Gel Process

  • Bae, Min-Ho;Lim, Kee-Joe;Kim, Hyun-Hoo;No, Kwang-soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.1
    • /
    • pp.42-45
    • /
    • 2002
  • Properties of lead zirconate titanate ferroelectric thin films prepared by rapid thermal annealing/direct insertion thermal annealing were investigated. The remnant polarization (Pr), saturation polarization (Ps), and coercive force (Ec) of typical samples annealed by rapid thermal annealing (RTA) are about 13.7 $\mu$ C/cm$^2$, 27.1 $\mu$C/cm$^2$, and 55.6 kV/cm, respectively. The dielectric constant of the sample is about 786, the dielectric loss tangent is about 2.4% at 1 kHz. Furthermore, ferroelectric, conduction, and piezoelectric properties of the thin films annealed by RTA process and the direct insertion thermal annealing (DITA) process were compared. The influence of temperature in the dry process on the above properties was also investigated.

LBLOCA AND DVI LINE BREAK TESTS WITH THE ATLAS INTEGRAL FACILITY

  • Baek, Won-Pil;Kim, Yeon-Sik;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.775-784
    • /
    • 2009
  • This paper summarizes the tests performed in the ATLAS facility during its first two years of operation (2007${\sim}$2008). Two categories of tests have been performed successfully: (a) the reflood phase of the large-break loss-of-coolant accidents in a cold leg, and (b) the breaks in one of four direct vessel injection lines. Those tests contributed to understanding the unique thermal-hydraulic behavior, resolving the safety-related concerns and providing an evaluation of the safety analysis codes and methodology for the advanced pressurized water reactor, APR1400. Several important and interesting phenomena have been observed during the tests. In most cases, the ATLAS shows reasonable accident characteristics and conservative results compared with those predicted by one-dimensional safety analysis codes. A wide variety of small-break LOCA tests will be performed in 2009.