• Title/Summary/Keyword: Direct Imaging

Search Result 421, Processing Time 0.024 seconds

Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients (일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교)

  • Seok, Hyo Hyun;Kwon, Geun-Yong;Baek, Seung-Hak;Choi, Tae Hyun;Kim, Sukwha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

Cortical Activation by Transcranial Direct Current Stimulation and Functional Electrical Stimulation in Normal Subjects: 2 Case Studies (정상 성인에서 경두개 직류 전류자극과 기능적 전기자극에 의한 대뇌피질의 활성화: 사례연구)

  • Kwon, Yong-Hyun;Kwon, Jung-Won;Park, Sang-Young;Jang, Sung-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.77-82
    • /
    • 2011
  • Purpose: Recently, many studies have demonstrated that application of external stimulation can modulate cortical excitability of the human brain. We attempted to observe cortical excitability using functional magnetic resonance imaging (fMRI) during the application of transcranial direct current stimulation (tDCS) or functional electrical stimulation (FES). Methods: We recruited two healthy subjects without a history of neurological or psychiatric problems. fMRI scanning was done during? each constant anodal tDCS and FES session, and each session was repeated three times. The tDCS session consisted of three successive phases (resting phase: 60sec dummy cycle: 10sec tDCS phase: 60sec). The FES session involved stimulation of wrist extensor muscles over two successive phase (resting phase: 15sec FES phase: 15sec). Results: The average map of the tDCS and FES analyses showed that the primary sensory-motor cortex area was activated in all subjects. Conclusion: Our findings show that cortical activation can be induced by constant anodal tDCS and FES. They suggest that the above stimuli have the potential for facilitating brain plasticity and modulating neural excitability if applied as specific therapeutic interventions for brain injured patients.

Gravure Halftone Dots by Laser Direct Patterning (레이저 직접 패터닝에 의한 그라비아 망점 형성)

  • Suh, Jeong;Han, You-Hie;Kang, Lae-Heuck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.191-198
    • /
    • 2000
  • Laser direct patterning of the coated photoresist (PMER-NSG31B) layer was studied to make halftone dots on gravure printing roll. The selective laser hardening of photoresist by Ar-ion laser(wavelength: 333.6~363.8nm) was controlled by the A/O modulator. The coating thickness in the range of 5~11$\mu m$ could be obtained by using the up-down directional moving device along the vertically located roll. The width, thickness and hardness of the hardened lines formed under the laser power of 200~260㎽ and irradiation time of 4.4~6.6 $\mu$sec/point were investigated after developing. The hardened width increased as the coating thickness increased. Though the hardened thickness was changed due to the effect of the developing solution, the hardened layer showed good resistance to the scratching of 2H pencil. Also, the hardened minimum line widths of 10$\mu m$ could be obtained. The change of line width was also found after etching, and the minimum line widths of 6$\mu m$ could be obtained. The hardened lines showed the good resistance to the etching solution. Finally, the experimental data could be applied to make gravure halftone dots using the developed imaging process, successfully.

  • PDF

A review of the Implementation of Functional Brain Imaging Techniques in Auditory Research focusing on Hearing Loss (청각 연구에서 기능적 뇌 영상 기술 적용에 대한 고찰: 난청을 중심으로)

  • Hye Yoon Seol;Jaeyoung Shin
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.26-36
    • /
    • 2024
  • Functional brain imaging techniques have been used to diagnose psychiatric disorders such as dementia, depression, and autism. Recently, these techniques have also been actively used to study hearing loss. The present study reviewed the application of the functional brain imaging techniques in auditory research, especially those focusing on hearing loss, over the past decade. EEG, fMRI, fNIRS, MEG, and PET have been utilized in auditory research, and the number of research studies using these techniques has been increasing. In particular, fMRI and EEG were the most frequently used technique in auditory research. EEG studies mostly used event-related designs to analyze the direct relationship between stimulus and the related response, and in fMRI studies, resting-state functional connectivity and block designs were utilized to analyze alterations in brain functionality in hearing-related areas. In terms of age, while studies involving children mainly focused on congenital and pre- and post-lingual hearing loss to analyze developmental characteristics with and without hearing loss, those involving adults focused on age-related hearing loss to investigate changes in the characteristics of the brain based on the presence of hearing loss and the use of a hearing device. Overall, ranging from EEG to PET, various functional brain imaging techniques have been used in auditory research, but it is difficult to perform a comprehensive analysis due to the lack of consistency in experimental designs, analysis methods, and participant characteristics. Thus, it is necessary to develop standardized research protocols to obtain high-quality clinical and research evidence.

Apparatus and method for analysing spectral response of a CCD optical sensor using an infrared imaging technique (적외선 영상기법에 의한 CCD 센서의 스펙트럼 응답 특성 분석 기법)

  • Kang Seong-Jun;Na Cheol-Hun;Park Soon-Young
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.25-30
    • /
    • 2006
  • An infrared imaging method is proposed in which direct measurement of the spectral response of CCD sensors can be achieved through digital image processing. This method allows for a simple and economic method to detect the spectral sensitivity of commercialized CCD sensors. The key components of the apparatus are a monochromator, CCD-sample supporter and a personal computer equipped with a digital image processing systems. Tentative experimentation conducted on the commercialized CCD camera has resulted in a fairly consistent agreement with the theoretical model.

Brain Magnetic Resolution Imaging to Diagnose Bing-Neel Syndrome

  • Kim, Ho-Jung;Suh, Sang-Il;Kim, Joo-Han;Kim, Byung-Jo
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.588-591
    • /
    • 2009
  • Radiologic findings of Bing-Neel syndrome, which is an extremely uncommon complication resulting from malignant lymphocyte infiltration into the central nervous system (CNS) in patients with Waldenstr$\ddot{o}$m's macroglobulinemia (WM), have been infrequently reported due to extreme rarity of the case. A 75-year-old man with WM presented at a neurology clinic with progressive gait and memory disturbances, and dysarthria of 2 months duration. Cerebrospinal fluid and serum protein electrophoresis and immunofixation electrophoresis showed IgM kappa-type monoclonal gammopathy. Brain magnetic resonance imaging revealed multifocal, hyperintense lesions on T2 weighted-images. Brain diffusion-weighted imaging (DWI) demonstrated hyperintensities in cerebral and cerebellar lesions that appeared isointense on apparent diffusion coefficient maps, which were compatible with vasogenic edema. Although histologic analysis is a confirmative study to prove direct cell infiltration into the brain, brain MRI with DWI may be a good supportive study to diagnose Bing-Neel syndrome.

NEW DESIGN CONCEPT FOR UNIVERSAL CCD CONTROLLER

  • Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.41-52
    • /
    • 1994
  • Currently, the CCDs are widely used in astronomical observations either in direct imaging use or spectroscopic mode. However according to the recent technical advances, new large format CCDs are rapidly developed which have better performances with higher quantum efficiency and sensitivity. In many cases, some microprocessors have been adopted to deal with necessary digital logic for a CCD imaging system. This could often lack the flexibility of a system for a user for to upgrade with new devices, especially if it is a commercial product. A new design concept has been explored which could provide the opportunity to deal with any format of devices from any manufactures effectively for as tronomical purposes. Recently available PLD (Programmable Logic Devices)technology makes it possible to develop such digital circuit design, which can be integrated into a single component, instead of using micrprocessors. The design concept could dramatically increase the efficiency and flexibility of a CCD imaging system, particularly when new or large format devices are available and to upgrade the performance of a system. Some variable system control parameters can be selected by a user with a wider range of choice. The software can support such functional requirements very conveniently. This approach can be applied not only to astronomical purpose, but also to some related fields, such as remote sensing and industrial applications.

  • PDF

Analyzing the Spray-to-spray Interaction of GDI Injector Nozzle in the Near-field Using X-ray Phase-Contrast Imaging (X선 위상차 가시화 기법을 이용한 GDI 인젝터 노즐 근방의 분무 간 상호간섭 해석)

  • Bae, Gyuhan;Moon, Seoksu
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.60-67
    • /
    • 2020
  • Despite its benefit in engine thermal efficiency, gasoline-direct-injection (GDI) engines generate substantial particulate matter (PM) emissions compared to conventional port-fuel-injection (PFI) engines. One of the reasons for this is that the spray collapse caused by the spray-to-spray interaction forms the locally rich fuel-air mixture and increases the fuel wall film. Previous studies have investigated the spray collapse phenomenon through the macroscopic observation of spray behavior using laser optical techniques, but it is somewhat difficult to understand the interaction between sprays that is initiated in the near-nozzle region within 10 mm from the nozzle exit. In this study, the spray structure, droplet size and velocity data were obtained using an X-ray imaging technique from the near-nozzle to the downstream of the spray to investigate the spray-to-spray interaction and discuss the effects of spray collapse on local droplet size and velocity distribution. It was found that as the ambient density increases, the spray collapse was promoted due to the intensified spray-to-spray interaction, thereby increasing the local droplet size and velocity from the near-nozzle region as a result of droplet collision/coalescence.

3-D CT Imaging of Pathological Bone Changes in a Rat Model of Adjuvant-Induced Arthritis

  • Shim, Kyung-Mi;Kim, Se-Eun;Kang, Seong-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.41-46
    • /
    • 2008
  • Computed tomography (CT) is a medical imaging method employing tomography. CT is a 3-Dimensional (3-D) radiographic imaging technique, which is not suited for assessment of inflammation, but can be considered a reference method for assessment of bone damage, due to its direct 3-D visualization of calcified tissue. In this study of pathological joint changes in a rat model of adjuvant-induced arthritis (AIA) and quality analysis of bone destructions were performed by 3-Dimensional computed tomography images. These data demonstrate that the destructive progression of disease in a rat AIA model can be quantified using 3-D CT image analysis, which allows assessment of arthritic disease status and efficacy of experimental therapeutic agents.

  • PDF

A rare case of isolated schwannoma in infraorbital nerve

  • Choi, June Seok;Park, Sang Min;Choi, Kyung-Un
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.231-234
    • /
    • 2018
  • A schwannoma is a benign tumor that develops from Schwann cells. It is known to occur more frequently in women than men, and about one third of schwannoma cases occur in the head and neck area. It is also known to originate mainly in the auditory nerve. However, it is rarely associated with the trigeminal nerve, and especially, schwannomas related to the infraorbital nerve are very rare. we report a rare case of a schwannoma involving the infraorbital branch of the trigeminal nerve in a 45-year old male adult. The patient underwent physical examination and magnetic resonance imaging. The mass was approached through subciliary approach that is familiar to the plastic surgeon and completely resected. Histopathological findings showed pointed to a benign schwannoma. Infraorbital nerve schwannoma is difficult to distinguish from other diseases by means of clinical symptoms, physical findings, or imaging. In spite of its rarity, infraorbital nerve schwannoma may be considered a possible diagnosis in the case of mass on cheek. Assessment by computed tomography or magnetic resonance imaging is necessary for proper diagnosis. About the surgical approach, excision through the subciliary approach should be considered rather than the direct transfacial approach in view of stability, cosmetic effects, and familiarity.