• 제목/요약/키워드: Direct Frequency Analysis

검색결과 666건 처리시간 0.03초

Fluid-conveying piezoelectric nanosensor: Nonclassical effects on vibration-stability analysis

  • Kachapi, Sayyid H. Hashemi
    • Structural Engineering and Mechanics
    • /
    • 제76권5호
    • /
    • pp.619-629
    • /
    • 2020
  • In current study, surface/interface effects for pull-in voltage and viscous fluid velocity effects on dimensionless natural frequency (DNF) of fluid-conveying piezoelectric nanosensor (FCPENS) subjected to direct electrostatic voltage DC with nonlinear excitation, harmonic force and also viscoelastic foundation (visco-pasternak medium and structural damping) are investigated using Gurtin-Murdoch surface/interface (GMSIT) theory. For this analysis, Hamilton's principles, the assumed mode method combined with Lagrange-Euler's are used for the governing equations and boundary conditions. The effects of surface/interface parameters of FCPENS such as Lame's constants (λI,S, μI,S), residual stress (τ0I,S), piezoelectric constants (e31psk,e32psk) and mass density (ρI,S) are considered for analysis of dimensionless natural frequency respect to viscous fluid velocity u̅f and pull-in voltage V̅DC.

Wide Speed Direct Torque and Flux Controlled IPM Synchronous Motor Drive Using a Combined Adaptive Sliding Mode Observer and HF Signal Injection

  • Foo, Gilbert;Rahman, M.F.
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.582-592
    • /
    • 2009
  • This paper proposes a new speed sensorless direct torque and flux controlled interior permanent magnet synchronous motor (IPMSM) drive. Closed-loop control of both the torque and stator flux linkage are achieved by using two proportional-integral (PI) controllers. The reference voltage vectors are generated by a SVM unit. The drive uses an adaptive sliding mode observer for joint stator flux and rotor speed estimation. Global asymptotic stability of the observer is achieved via Lyapunov analysis. At low speeds, the observer is combined with the high frequency signal injection technique for stable operation down to standstill. Hence, the sensorless drive is capable of exhibiting high dynamic and steady-state performances over a wide speed range. The operating range of the direct torque and flux controlled (DTFC) drive is extended into the high speed region by incorporating field weakening. Experimental results confirm the effectiveness of the proposed method.

해석적 주파수종속 무한요소를 사용한 시간영역해석의 지반-구조물의 상호작용을 고려한 지진해석 (Time Domain Soil-Structure Interaction Analysis for Earthquake Loadings Based on Analytical Frequency-Dependent Infinite Elements)

  • Kim, Doo-Kie;Yun, Chung-Bang
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.121-128
    • /
    • 1999
  • This paper presents a time domain method for soil-structure interaction analysis for seismic loadings. It is based on the finite element formulation incorporating analytical frequency-dependent infinite elements for the far field soil. The dynamic stiffness matrices of the far field region formulated using the present method in frequency domain can be easily transformed into the corresponding matrices in time domain. At first, the equivalent earthquake forces are evaluated along the interface between the near and the far fields from the free-field response analysis carried out in frequency domain, and the results are transformed into the time domain. An efficient procedure is developed for the convolution integrals to evaluate the interaction force along the interface, which depends on the response on the interface at the past time instances as well as the concurrent instance. Then, the dynamic responses are obtained for the equivalent earthquake force and the interaction force using Newmark direct integration technique. Since the response analysis is carried out in time domain, it can be easily extended to the nonlinear analysis. Example analysis has been carried out to verify the present method in a multi-layered half-space.

  • PDF

산업용 위험기계 및 기구관련 산재예방 정책 연구 (Safety Policies on Prevention of Industrial Accidents Associated with Industrial Machines and Devices)

  • 최기흥
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.26-33
    • /
    • 2015
  • This study suggests systematic procedures to improve safety policies on prevention of industrial accidents associated with industrial machines and devices. Specifically, new method of cause analysis of industrial accidents associated with industrial machines and devices is suggested and the related accident data are re-analyzed. Effectiveness of direct safety regulations such as safety certification, self-declaration of conformity, safety device regulation and safety inspection of industrial machines and devices are also analyzed. Based on those analysis results, transition from the current user-oriented safety device regulation to more balanced direct regulations on both manufacturer and user is suggested. Together with severity and frequency of industrial accidents, unit severity and unit frequency need to be taken into account to further assess the risk associated with a particular industrial machine or device. Balance between safety regulations will be realized by proper adjustment of lists of safety certification and inspection, and certification and inspection standards. This will also guarantee the maximum benefit over cost in such safety regulations.

자속 및 토오크 히스테리시스 밴드폭에 따른 직접토오크 제어 (Direct Torque Control according to Flux and Torque of Hysterisis Band)

  • 최연옥;정삼용;김대곤;김평호;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1206-1208
    • /
    • 2001
  • Direct torque control(DTC) of AC motor has the fast torque and flux dynamic responses even though it has very simple scheme to implement. DTC is also very simple in its implementation because it needs only two hysteresis comparators and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple, switching frequency and current harmonics. Therefore, authors analysis flux and torque hysteresis bands is suggested considering switching frequency and harmonic distortion of currents.

  • PDF

X-band용 직결합 대수주기형 마이크로스트립 안테나 (A Directly Coupled Log Periodic Microstrip Antenna for X-band)

  • 임규재;고성선;윤현보
    • 한국통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.182-191
    • /
    • 1988
  • 직결합(direct coupling) 급전 방식을 사용한 대수 주기형으로 배열된 마이크로 스트립 안테나(Log Periodic Microstrip Array Antenna)를 7.2-12.4GHz주파수 대역에서 설계하였다. 전송 선로 해석 방법에 유전체 및 도체 손실과 불연속에 의한 영향을 고려하여 각 안테나 소자를 설계하였으며 주 전송 선로와 각 안테나 소자 간의 임피던스 정합을 위하여 급전 위치를 최적화하여 정하였다. 측정한 결과 전 주파수 대역에서 정재파비가 2.4이하여??며 53%의 대역폭을 얻었다.

  • PDF

고속 CORDIC에 기반한 직접 디지털 주파수 합성기 (Hight throughput CORDIC-based Direct Digital Frequency Synthesizer)

  • Park, Minkyoung;Park, Sungsoo;Kim, Kiseon;Lee, Jeong-A
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.784-787
    • /
    • 1999
  • This paper describes a direct digital frequency synthesizer using the CORDIC algorithm, which can be implemented efficiently for a digital sinusoid synthesis. To optimize the hardware design parameters, we perform numerical analysis of the quantization effects for the CORDIC-based architecture. A pipelined architecture is employed to obtain a high data throughput,. We estimate and summarize its hardware costs for a variable accuracy, and a CORDIC-based architecture for 9 bit accuracy is emulated in FPGA.

  • PDF

웨이브렛 변환과 평균예측검색 알고리즘의 벡터양자화를 이용한 심전도 데이터 압축기법 (ECG Data Compression Technique Using Wavelet Transform and Vector Quantization on PMS-B Algorithm)

  • 은종숙;신재호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.225-228
    • /
    • 1996
  • ECG data are used for the diagnostic purposes with many clinical situations, especially heart disease. In this paper, an efficient ECG data compression technique by wavelet transform and high-speed vector quantization on PMS-B algorithm is proposed. In general, ECG data compression techniques are divided into two categories: direct and transform methods. The direct data compression techniques are AZTEC, TP, CORTES, FAN and SAPA algorithms, besides the transform methods include K-L, Fourier, Walsh, and wavelet transforms. In this paper, we applied wavelet analysis to the ECG data. In particular, vector quantization on PMS-B algorithm to the wavelet coefficients in the higher frequency regions, but scalar quantized in the lower frequency regions by PCM. Finally, the quantized indices were compressed by LZW lossless entropy encoder. As the result of simulation, it turns out to get sufficient compression ratio while keeping clinically acceptable PRD.

  • PDF

Krylov 부공간 모델차수축소법을 이용한 주파수응답함수의 직접 설계민감도 해석 (Direct Design Sensitivity Analysis of Frequency Response Function Using Krylov Subspace Based Model Order Reduction)

  • 한정삼
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.153-163
    • /
    • 2010
  • Krylov 부공간 모델차수축소법은 초기 유한요소모델과 축소모델의 전달함수의 계수인 모멘트를 일치시키는 방법을 이용하는 축소기법으로 이미 대형 유한요소모델의 주파수응답함수의 효율적인 계산에 많이 사용되고 있는 방법 중의 하나이다. 본 논문에서는 Krylov 부공간 축소기법을 이용한 관심 주파수영역에 대한 주파수응답 해석과 이를 통하여 계산된 주파수응답의 여러 가지 설계변수에 대한 설계민감도 해석 방법을 제안하였다. 일반적으로 기계시스템의 주파수응답을 고려한 최적설계를 위해서는 설계변수에 대한 관심 주파수영역에서의 주파수응답 및 그의 민감도 정보가 요구되므로, 고려하는 유한요소모델이 대형일 경우에는 관심 주파수영역에서의 반복적인 해석으로 인한 계산비용의 문제가 심각하게 대두된다. 본 논문에서는 축소모델을 이용하여 주파수응답과 주파수응답의 설계민감도 해석을 수행하여 계산의 효율성을 극대화하였다. 계산상 시스템행렬의 민감도 계산에는 시간측면과 구현의 용이성 측면에서 장점이 있는 준해석적 방법을 이용하였다. 수치 예제를 통하여 축소기법을 이용한 주파수응답의 설계민감도 해석 결과를 초기 유한요소모델의 민감도 결과와 비교하여 우수한 정확성 및 효율성을 확인하였다. 본 논문에서 제안된 방법을 주파수응답을 고려하는 최적설계에 이용하는 경우, 결과의 정확성 및 계산비용 측면에서 매우 효과적인 방법이 될 수 있을 것으로 판단된다.

산업용 기계 제조자와 사용자 대상 직접규제의 균형과 실효성 분석 (Balance and Effectiveness of Direct Regulations on Manufacturers and Users of Industrial Machines)

  • 최기홍
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.1-7
    • /
    • 2015
  • This study first addresses the ineffectiveness of indirect regulation on industrial machines. Analysis of causes of industrial accidents associated with industrial machines further reveals the fact that technical causes need to be resolved at the manufacturing stage to reduce the frequency and strength of industrial accidents. Balanced safety certification on manufacturers and safety inspection on users of industrial machines are then suggested to effectively resolve such technical causes. The effectiveness of such safety certification and safety inspection can be justified by cost-benefit analysis. Particularly, balance in expected benefits of safety certification and safety inspection is a key issue for validity of such analysis. The accumulated benefit-costs for press brake and portable sawing machine confirm the effectiveness of such safety system.