• Title/Summary/Keyword: Direct Detection

Search Result 926, Processing Time 0.023 seconds

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique (반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.71-79
    • /
    • 2008
  • High voltage distribution lines in the electric railway system placed according track with communication lines and signal equipments. Case of the over head lines is occurrence the many fault because lightning, rainstorm, damage from the sea wind and so on. According this fault caused protection device to wrong operation. One line ground fault that occurs most frequently in railway high voltage distribution lines and sort of faults is line short, three line ground breaking of a wire, and so on. For this reason we need precise maintenance for prevent of the faults. The most important is early detection and fast restoration in time of fault for a safety transit. In order to develop an advanced fault location device for 22.9[kV] distribution power network in electric railway system this paper deals with new fault locating algorithm using flow technique which enable to determine the location of the fault accurately. To demonstrate its superiorities, the case studies with the algorithm and the fault analysis using PSCAD/EMTDC (Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) were carried out with the models of direct-grounded 22.9[kV] distribution network which is supposed to be the grounding method for electric railway system in Korea.

Development of Optimum PAC Dose Prediction Program using $^{14}C$-radiolabled MIB and HSDM ($^{14}C$-radiolabeled MIB와 HSDM을 이용한 최적 PAC 투입량 예측프로그램의 개발)

  • Kim, Young-Il;Bae, Byung-Uk;Kim, Kyu-Hyoung;Hong, Hyun-Su;Westerhoff, Paul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1123-1128
    • /
    • 2005
  • NIB(methylisoborneol) is an earthy/musty odor compound produced as a second metabolite by cyanobacteria and actinomycetes. MIB is not removed by conventional water treatment(coagulation, sedimentation, filtration) and its presence in tap water, even at low ng/L levels, can result in consumer complaints. PAC(powdered activated carbon) can effectively remove MIB when the correct dose is applied. But, since most operators in water treatment plants apply a PAC dose and then adjust that dose depending on direct observation (odor detection) after treatment, the result is often under-dose or eve,-dose. In this study, kinetic and isotherm tests using $^{14}C$-radiolabeled MIB were performed to determine coefficients for the HSDM(homogeneous surface diffusion model), including liquid film mass transfer coefficient($K_f$) and surface diffusion coefficient ($D_s$). The HSDM gave a reasonable fit and allowed prediction with the experimental data. Base on the HSDM, the authors developed an optimum PAC dose prediction program using the Excel spreadsheet. When the developed program was applied at two water treatment plants, the PAC dose based on the experience of operators in the water treatment plant was significantly different from that recommended by the newly developed program. If operators are willing to use the optimum PAC dose prediction program, it should solve dosing problems.

An Analysis of FSK Transmission Characteristics of Spectrum Sliced Optical Signals (스펙트럼 분할된 광신호의 FSK 전송 특성 해석)

  • Ha, Eun-Sil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.339-344
    • /
    • 2016
  • Since transmissions of large amounts of data are frequent, users require more bandwidth, and the need for communications networks having greater bandwidth is increasing. One communications network satisfying this need is an optical communications network. Therefore, studies to increase the transmission capacity of optical communications systems have been carried out. However, in a general optical communications system, a signal transmitted through optical fiber (a transmission medium) is detected through direct detection in the receiving system. This method has a disadvantage in that the entire bandwidth of the optical signal cannot be utilized. Also, when transmitting an optical signal, there is a problem where the signal-to-noise ratio is affected by neighboring channels. To overcome this situation, various studies are being conducted to minimize the influence of external interference and noise. This paper overcomes the situation by transmitting spectrum-sliced signals using the digital transmission system, FSK. Analyzing the characteristics of the signals detected in the receiver of the optical communications system, Gaussian distribution is used for the PDF of the spectrum-sliced signal, and the signal at the receiving end of the optical communications system is assumed to have a k-square distribution. The results of the analysis confirmed it is better to transmit the spectrally divided signal rather than transmit the laser source.

Accurate Analysis of Trace Phthalates and Method Validation in Cosmetics using Gas Chromatography with Mass Spectrometric Detection (화장품에 함유된 미량의 프탈레이트 함량을 정확히 분석하기 위한 가스크로마토그래피-질량분석 시험법 및 그 시험법의 유효성)

  • Kim, Min-Kee;Jeong, Hye-Jin;Cho, Jun-Cheol
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • An effective, environmentally friendly analytic methods using gas chromatography with mass spectrometric detector (GC-MSD) have been developed for the quantitative analysis of trace phthalate levels in cosmetics such as nail lacquer and hair spray. Since such cosmetics are largely comprised of organic solvents, conventional clean-up methods that have been widely used for phthalate analyses are in adequate. In addition, analysis of trace phthalate levels is notorious for its sensitivity to contamination, which causes high analytical values. A direct sample dilution method using an organic solvent was adopted to the sample preparation process to determine the exact amounts of phthalates and simultaneously avoid the high risk of secondary contamination. The method has many advantages including high accuracy, sensitivity, and simplicity in sample preparation. Dibutyl phthalate (DBP) and di (2-ethylhexyl) phthalate (DEHP) were selected for analysis because they have been frequently detected in cosmetics and consistently reported as endocrine disruptors in humans and animals. Internal standard method using two deuterium substitutes (DBP-$d_4$, DEHP-$d_4$) as the internal standard was also used. The results of 'Method validation' showed the capabilities of this method for the routine analysis of phthalates at the ppm level. The recovery ranges were between 95 % and 106.1 %, and relative standards deviations (RSD) were less than 3.9 % in fortified nail lacquer and hair spray samples at the concentration of $25{\mu}g/g$.

Effect of an Aqueous Chlorine Dioxide Generator and Effect on Disinfection of Fresh Fruits and Vegetables by Immersion Washing (이산화염소수 생성기의 생성효율 및 과.채류에 대한 침지 세정 살균효과)

  • Park, Kee-Jai;Jeong, Jin-Woong;Lim, Jeong-Ho;Jang, Jae-Hee;Park, Hee-Joo
    • Food Science and Preservation
    • /
    • v.15 no.2
    • /
    • pp.236-242
    • /
    • 2008
  • We investigated the optimum concentration of a $NaClO_2$ solution and the amount of gaseous $Cl_2$ for production of high yield and purity of aqueous $ClO_2$ by use of a gaseous chlorine-chlorite $ClO_2$ generator. This system produced lower concentrations of chlorine dioxide and is applicable for direct-use in food processing as a cleaner and sanitizer. The concentration of $NaClO_2$ solution and the amount of gaseous $Cl_2$ was varied from 0.01-0.1% and 100-1,000 g/hr, respectively. The concentrations of chlorite, chlorate, FAC (free available chlorine), and chlorine dioxide that were produced increased with increasing concentration of $NaClO_2$ solution and with the amount of gaseous $Cl_2$. The optimum concentration of $NaClO_2$ solution and amount of gaseous $Cl_2$ were 0.1% and 900 g/hr respectively. $ClO_2$ and FAC produced at these concentrations were 882.0 ppm and 8.0 ppm, with no detection of chlorite and chlorate. The yield and purity of $ClO_2$ were 97.0% and 96.0% respectively. Immersion-cleaning experiments showed that this protocol decreased the level of CFU/g by $10^3$- to $10^4$-fold, with a similar effect on fruit.

Cancer Screening Knowledge and Attitudes of Under- and Post-Graduate Students at Kasr Al Ainy School of Medicine, Cairo University, Egypt

  • Sedrak, Amal Samir;Galal, Yasmine Samir;Amin, Tarek Tawfik
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.3809-3816
    • /
    • 2016
  • Background: Increasing knowledge and awareness of cancer screening significantly influence health promotion behavior which could markedly reduce incidence rates. In many countries, health care providers are the principal source of information concerning cancer screening. This study was carried out to assess the level of knowledge concerning cancer screening among medical students, house officers and residents and to explore their attitude towards cancer screening practices. Materials and Methods: This cross-sectional study was conducted in Kasr Al Ainy Medical School at Cairo University in Egypt, with 300 undergraduate medical students and 150 postgraduates (interns and residents) enrolled. A pre-tested self-administered questionnaire was used to collect data from the study participants regarding personal and education-related information, knowledge about cancer screening and its sources, and attitude towards cancer screening. Results: More than 64% of participants had knowledge scores of ${\leq}10$ points (out of 24). The total knowledge score (out of 6 points) for breast cancer screening increased from $1.9{\pm}1.0$ to $2.3{\pm}1.2$ and $2.4{\pm}1.1$ for $4^{th}$, $5^{th}$ and $6^{th}$ year respectively, interns showed the highest score of $2.6{\pm}1.1$, P= 0.001. Year of enrollment at medical school was a significant positive predictor of acquiring knowledge about cancer screening (post graduate vs. undergraduate students) (OR= 1.30, C.I =1.01-1.63), lack of or none receiving of orientation/training about cancer screening was the sole negative significant predictor for proper knowledge about cancer screening (OR=0.50, C.I=0.31-0.82). Over 92% of students agreed that they had insufficient knowledge about cancer screening, 88.2% appraised the need to have enough knowledge in order to direct/advice patients, relatives and friends, and 93.7% required that the faculty should emphasize the importance of cancer screening in the delivered curricula at medical school. Conclusions: A relatively low to moderate level of knowledge about cancer screening was detected among the selected medical students regardless of their year of enrollment at medical school or their graduation status, which may implicate a negative impact on early cancer detection especially in a low resource country like Egypt.

Assessment of Environmental Contaminant Levels in Water, Sediments and Adjacent Soils and Spider from Several Stream Sites in Korea (국내 하천들의 수질, 하천 퇴적물, 주변 토양 및 별늑대거미 체내 중금속 축적량을 통한 환경오염도 평가)

  • Byun, Sang-Hyuk;Ryoo, Keon-Sang;Choi, Jong-Ha;Kim, Yong-Gyun;Lee, Hwa-Sung
    • Journal of Environmental Science International
    • /
    • v.17 no.3
    • /
    • pp.287-296
    • /
    • 2008
  • A comprehensive quality survey for heavy metals, organophosphorous and organochlorine residual pesticides, and coplanar PCBs in samples such as water, sediments and soils as well as spiders has been implemented. The samples were undertaken at nine stream sites and their vicinity in August 2006, representing different surrounding environments. The levels of PCBs were expressed as concentrations and WHO-TEFs. Among 12 coplanar PCBs as target compounds in this study, 2,3', 4,4', 5-PentaCB (IUPAC # 118) was the congener with the highest concentration. The total concentrations and TEF values of coplanar PCBs in Siheung stream sediment (heavy industrial complex site located in Ansan city) were 3915.50 pg/g and 0.8366 pg-TEQ/g on a dry weight basis, respectively. Such levels were around 40 times higher compared to sediment from Gapyung stream (green site located in the upper of Myunggi mountain). It is probably due to the direct input of PCBs trom PCBs treatment materials. Organophosphorous (EPN, dementon-s-methyl, diazinon, parathion, and phenthoate) and organochlorine (alpha-BHC, aldrin, 4,4'-DDT, 4,4'-DDE, endosulfan alpha and etc.) pesticides were not detected above 5 ppb of detection limits. The concentrations of Cu and Cd in water and sediment samples from Siheung stream were 44.11 and $0.17ug/m\ell$ and $713.42{\mu}g/g$ and $3.73{\mu}g/g$, respectively, which contained $20\sim40$ times higher concentrations than those from Gapyung stream. In addition to the water and sediment samples, the levels of heavy metals in spider from designated sampling sites were also determined. Heavy metals in spider collected near Siheung stream was appeared to be equivalent and/or a little higher levels with respect to other spiders. Furthermore, the ratio of relative heavy metals (Cu, Cd, and Pb) in spider from each stream site showed a correlation as similar as that of heavy metals in soil samples.

Effects of Joint Mobilization Techniques on the Joint Receptors (관절 가동운동(mobilization)이 관절 감수기(joint receptors)에 미치는 영향)

  • Kim, Suhn-Yeop
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.95-105
    • /
    • 1996
  • Type I, II, III are regarded as "true" joint receptors, type IV is considered a class of pain receptor. Type I, II and III mechanoreceptors, via static and dynamic input, signal joint position, intraarticular pressure changes, and the direction, amplitude, and velocity of joint movements. Type I mechanoreceptor subserve both static and dynamic physiologic functions. Type I are found primarily in the stratum fibrosum of the joint capsule and ligaments. Type I receptors have a low threshold for activation and are allow to adapt to changes altering their firing frequency. Type II receptors have a low threshold for activation. These dynamic receptors respond to joint movement. Type II receptors are thus termed rapidly adapting. Type II joint receptors are located at the junction of the synovial membrane and fibrosum of the joint capsule and intraarticular and extraarticular fat pads. Type III receptors have been found in collateral ligaments of the joints of the extremities. Morphologically similar to Golgi tendon organ. These dynamic receptors have a high threshold to stimulation and are slowly adating. Type IV receptors possess free nerve ending that have been found in joint capsule and fat pads. They are not normally active, but respond to extreme mechanical deformation of the joint as well as to direct chemical or mechanical irritation. Small amplitude oscillatory and distraction movements(joint mobilization) techniques are used to stimulate the mechanoreceptors that may inhibit the transmission of nociceptors stimuli at the spinal cord or brain stem levels.

  • PDF

Direct Deletion Analysis in Two Duchenne Muscular Dystrophy Symptomatic Females Using Polymorphic Dinucleotide (CA)n Loci within the Dystrophin Gene

  • Giliberto, Florencia;Ferreiro, Veronica;Dalamon, Viviana;Surace, Ezequiel;Cotignola, Javier;Esperante, Sebastian;Borelina, Daniel;Baranzini, Sergio;Szijan, Irene
    • BMB Reports
    • /
    • v.36 no.2
    • /
    • pp.179-184
    • /
    • 2003
  • Duchenne muscular dystrophy (DMD) is the most common hereditary neuromuscular disease. It is inherited manifestations. In some rare cases, the disease can also be manifested in females. The aim of the present study was to determine the molecular alteration in two cases of nonrelated DMD symptomatic carriers with no previous history of DMD. Multiplex PCR is commonly used to search for deletion in the DMD gene of affected males. This method could not be used in females because the normal X chromosome masks the deletion of the mutated one. Therefor, we used a set of seven highly polymorphic dinucleotide $(CA)_n$ repeat markers that lie within the human dystrophin gene. The deletions were evidenced by hemizygosity of the loci under study. We localized a deletion in the locus 7A (intron 7) on the maternal X chromosome in one case, and a deletion in the region of introns 49 and 50 on the paternal X chromosome in the other. The use of microsatellite genotyping within the DMD gene enables the detection of the mutant allele in female carriers. It is also a useful method to provide DMD families with more accurate genetic counseling.