• 제목/요약/키워드: Dipole Magnet

검색결과 23건 처리시간 0.021초

방사광가속기용 2극 전자석의 제작과 특성연구 (The manufacturing review and performance study of Synchrotron Radiation (S.R) DIPOLE MAGNET)

  • 김방광;최성덕;박성태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.588-592
    • /
    • 1992
  • The electrons, which are accelerated to nearly light speed from LINAC(Linear Accelerator), put into Storage Ring. And this electrons circulate in an ultra high vacuum chamber and their orbit is controlled by the electromagnets such as DIPOLE, QUADRUPOLE, SEXTUPOLE & CORRECTION MAGNET. Among them, the dipole magnet is to bend the electron and to produce Synchrotron Radiation(S.R). This paper describes the key point during manufacturing of this magnet, and introduce the field measurement results of the HEECO's successful prototype.

  • PDF

전기기계식 배터리 시스템용 초고속 전동발전기의 설계, 제작 및 모드별 특성 (Design, Manufacture and Performance Characteristics under Each Mode of High-Speed Motor/Generator for Electro-Mechanical Battery System)

  • 장석명;서진호;정상섭;최상규;함상용
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.400-407
    • /
    • 1999
  • This paper treated the design, manufacture and the performance characteristics under each mode of high speed motor/generator for an electro-mechanical battery(EMB). This machine is employed as an integral part of a flywheel energy storage system(FESS), i.e., a modular flywheel system to be used as a device for storing electrical or mechanical energy. In this machine, the magnetic field system is constructed by using special magnet array, dipole Halbach array with 16 permanent magnet segments and the armature is composed of a plastic bobbin and multi-phase windings with Litz wire. The magnet array produces a highly uniform dipole field without back iron. The motor/generator is 3-phase machine in which the dipole Halbach array surrounding the winding is rotating. Since there are no iron laminations, this field system offers some unique advantages for the simplicity of the design and the theoretical prediction of characteristics of a high speed electric machine. This paper describes the results obtained when EMB system was tested in the laboratory.

  • PDF

방사광 가속기용 2극 전자석 특성측정 및 보정 (Magnetic Measurement of PLS Storage Ring Prototype Dipole Magnet)

  • 강봉구;박기현;윤종렬;구양모
    • 한국자기학회지
    • /
    • 제2권2호
    • /
    • pp.163-168
    • /
    • 1992
  • 포항 방사광 가속기 저장링용 시제품 2극전자석의 특성측정 및 보정결과에 대하여 기술 하였다. 전자석의 저장특성 측정을 위해 Hall probe mapping 기법과 rotating coil 기법과 rotating coil 기법을 동시에 사용하였다. 자장측정 결과로부터 2극전자석의 요구조건을 만족하도록 자극의 양 쪽 끝 부분을 수정하였다. 보정이 끝난 전자석은 2.0 GeV의 beam energy로 동작시킬 경우(1.058 Tesla) 약 99.7%의 효율을 얻었으며, 4극 이상의 다극 오차성분도 허용오차 범위 미만으로 포항 방사광 가속 기 저장링용 2극 전자석으로 적합함이 판명 되었다.

  • PDF

SSC 쌍극자 마그네트의 퀜치 특성에 대한 연구 (Quench Characteristics of SSC Dipole Magnet Prototypes)

  • 나완수;류강식;권영길;조전욱;진홍범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1078-1080
    • /
    • 1993
  • The quench performance and ramp rate sensitivity of eighteen 5-cm-aperature, 15-m-long SSC dipole magnet prototypes are discussed. All the magnets appear to reach a quench plateau near their extrapolated short sample current limit and well in excess of the operating current with very little training. Most of the magnets, however, exibit a dramatic degradation of thier quench current as a function of ramp rate, which for the most part, can be attributed to large cable eddy currents.

  • PDF

Design of Low Field RF Coil for Open MRI System by Electric Dipole Radiation

  • 김경락;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.174-174
    • /
    • 2001
  • Purpose: Dimensions of body RF coil composed of 4 rectangular loops for low field open MRI hav been optimized. The design result shows the field inhomogeneity of B1 field below 1.5 dB in the 25 cm DSV can be achieved. Method: Our low field RF coil is composed of 4 rectangular strip loops that assumed to b located at both the bottom and top sides of permanent magnet. All the loops have identica dimensions and current amplitude. First, the inductance of a loop is calculated. Second, the current distribution on the coil strip is calculated by using finite difference time doma method (FDTD). It takes as much as 4 days in FDTD simulation for low frequency RF field That's why the electrical dipole radiation method is used for simulation. With the curren distribution obtained using the FDTD simulation, for various dimensional parameters th magnetic field has been calculated by electric dipole radiation method, where the curren elements are regarded as electric dipole radiation sources. The field pattern from electri dipole radiation is almost same as that from FDTD simulation. Also, it is same as that fro the result using the Viot-Savart equation, for far tone radiation term becomes zero and th Bl field amplitude of near one radiation is the same as the B field due to static current The field homogeneity is calculated in the 25 cm BSV.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

축소 모델을 이용한 함정 자기장 신호 해석 기법 연구 (Study on Analysis Method for Ship's Ferromagnetic Signature using Magnetic Mock-up Model)

  • 양창섭;정현주
    • 한국군사과학기술학회지
    • /
    • 제10권4호
    • /
    • pp.38-51
    • /
    • 2007
  • This paper describes research results for the measurement and analysis method of magnetic signatures generated from the ship's magnetic mock-up model. In this paper, we present the theoretical and experimental techniques for the separation of the permanent and the induced magnetic field from the measured magnetic signature of the mock-up model. Also, we describe the prediction method of the induced magnetic field generated from mock-up model using the Magnet s/w, one of the FEM analysis tools for the electro-magnetic field and the magnetic dipole modelling method based on the least square techniques. The proposed modelling and analysis methods can be used for the prediction and the analysis of the static magnetic field generated from the real naval ship as well as the mock-up model.

자장의 배열 및 형태가 유도결합형 플라즈마에 미치는 효과에 관한 연구 (A study on the effects of variously configured magnets on the characteristics of inductively coupled plasma)

  • 황순원;이영준;유지범;이재찬;염근영
    • 한국표면공학회지
    • /
    • 제32권4호
    • /
    • pp.513-520
    • /
    • 1999
  • In this study, we investigated the effects of variously configured magnets on the characteristics of the plasmas to enhance plasma uniformity and density of an inductively coupled plasma source. As the magnets, Helmholtz type axial electromagnets and various multi-dipole magnets types around the chamber wall were used. To characterize the plasma as a function of the combination of the magnets and magnetic field strengths, ion density, electron temperature, and plasma potential were measured using an electrostatic probe along the chamber diameter for Ar plasmas. The measured maximum ion densities were $8$\times$10^{ 11}$$cm^{-3}$ with 600W inductive power and at 5mTorr of operational pressure and the uniformity of ion density was less than 5.9% at 2mTorr of operational pressure. The combination of an optimized multi-dipole magnet type and an axial electromagnet showed the lowest electron temperature (3eV) and plasma potential ($34V{p}$ )

  • PDF

치료용 입자가속기를 위한 고속 스케닝 전자석 전원공급장치 개발 (Development of fast scanning magnet power supply for particle accelerator therapy)

  • 김동수;김영우;유효열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.91-92
    • /
    • 2014
  • 본 논문은 고속 Scanning 전자석 전원공급 장치를 제작하여 한국 원자력 의학원에 납품하였고, 전원 장치성능을 확인하였다. 한국 원자력 의학원에서 요구 사양은 전류 기울기가 440 kA/s와 출력 전압 / 전류는 ${\pm}530V$ / ${\pm}80A$이며, 과도상태 이후의 전류 정밀도는 ${\pm}100ppm$ 이하를 만족하는 전원장치 이다. 전류가 고속으로 증가하기 때문에 출력 케이블과 전자석 자체의 표피효과로 인해 구간별 성능에 미진한 부분이 확인되어 추가 연구개발이 요구된다.

  • PDF

Synthesis and Photoinduced Magnetic Properties of a Mn12 Single Molecule Magnet by the cis-trans Isomerism of Azobenzene

  • George, Sheby M.;Kim, Jin-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권5호
    • /
    • pp.1143-1146
    • /
    • 2009
  • [$Mn_{12}O_{12}(azo-L)_{16}(H_2O)_4$] (1), a new Mn12 single molecule magnet containing a photochromic azobenzene ligand, has been successfully synthesized by substitution of acetate ligand of Mn12 with 6-[4-{4-hexyloxyphenyl( azo)}-phenoxy]hexanoic-1-acid. The reversible photoisomerization of the azobenzene group was confirmed by UV-visible absorption spectroscopy. The temperature and field dependence of dc susceptibility and the temperature and the frequency dependence of ac susceptibility were measured for the cis and the trans isomer of 1. The magnetization value of the cis isomer in dc measurement is higher than that of the trans isomer. The cis isomer of 1 has a slower relaxation because cis-trans photoisomerization of the azobenzene group in peripheral ligands induces changes in its structure and dipole moment.