• Title/Summary/Keyword: Diode)

Search Result 4,486, Processing Time 0.049 seconds

Development of Method for Analysis of Four Sulfonylurea Pesticides, Rimsulfuron, Ethametsulfuron-methyl, Tribenuron-methyl, Chlorimuron-ethyl Residues by High-Performance Liquid Chromatography with Diode-Array Detection (HPLC/DAD를 이용한 림술푸론, 에타메트설푸론메틸, 트리베누론메칠, 클로리무론에칠 4종 성분의 잔류농약 분석법 개발)

  • Koo, Yun-Chang;Yang, Sung-Yong;Wang, Zeng;An, Eun-Mi;Heo, Kyoung;Kim, Hyeng-Kook;Shin, Han-Seung;Lee, Jin-Won;Lee, Kwang-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.8
    • /
    • pp.1231-1235
    • /
    • 2010
  • The method for residue analysis of four sulfonylurea pesticides, rimsulfuron, ethametsulfuron-methyl, tribenuron-methyl and chlorimuron-ethyl was examined and analyzed by HPLC with ODS column ($250\;mm{\times}4.6\;mm$, $5\;{\mu}m$ diameter particle size) which was maintained at $35^{\circ}C$. Mobile phase consisted of solvent A (20 mM $KH_2PO_4$, pH 2.5) and solvent B (acetonitrile). Isocratic elution of the column with 45% solvent A and 55% solvent B at a flow rate of 1 mL/min resulted in retention times of 5.92, 6.54, 9.28, and 14.35 min for rimsulfuron, ethametsulfuron-methyl, tribenuron-methyl, and chlorimuron-ethyl, respectively. All injection volumes were $20\;{\mu}L$. The limit of quantitation was 0.02, 0.01, 0.001, and 0.004 mg/kg for rimsulfuron, ethametsulfuron-methyl, tribenuron-methyl, and chlorimuron-ethyl, respectively. Recovery rate test was performed with three farm products, rice, apple and soybean. Four sulfonylurea pesticides were spiked at concentrations of 0.05, 0.1 and 0.5 mg/kg. The recovery rates were ranged from 86.12% to 116.26% and the standard deviations of all experiments were within 10%.

Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator

  • Cho, Jin Dong;Chun, Minsoo;Son, Jaeman;An, Hyun Joon;Yoon, Jeongmin;Choi, Chang Heon;Kim, Jung-in;Park, Jong Min;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.29 no.3
    • /
    • pp.92-100
    • /
    • 2018
  • The manufacturer of a linear accelerator (LINAC) has reported that the target melting phenomenon could be caused by a non-recommended output setting and the excessive use of monitor unit (MU) with intensity-modulated radiation therapy (IMRT). Due to these reasons, we observed an unexpected beam interruption during the treatment of a patient in our institution. The target status was inspected and a replacement of the target was determined. After the target replacement, the beam profile was adjusted to the machine commissioning beam data, and the absolute doses-to-water for 6 MV and 10 MV photon beams were calibrated according to American Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocol. To verify the beam data after target replacement, the beam flatness, symmetry, output factor, and percent depth dose (PDD) were measured and compared with the commissioning data. The difference between the referenced and measured data for flatness and symmetry exhibited a coincidence within 0.3% for both 6 MV and 10 MV, and the difference of the PDD at 10 cm depth ($PDD_{10}$) was also within 0.3% for both photon energies. Also, patient-specific quality assurances (QAs) were performed with gamma analysis using a 2-D diode and ion chamber array detector for eight patients. The average gamma passing rates for all patients for the relative dose distribution was $99.1%{\pm}1.0%$, and those for absolute dose distribution was $97.2%{\pm}2.7%$, which means the gamma analysis results were all clinically acceptable. In this study, we recommend that the beam characteristics, such as beam profile, depth dose, and output factors, should be examined. Further, patient-specific QAs should be performed to verify the changes in the overall beam delivery system when a target replacement is inevitable; although it is more important to check the beam output in a daily routine.

Antimicrobial Effects of Photodynamic Therapy using Photofrin Against Staphylococcus aureus and Staphylococcus epidermidis (포토프린을 이용한 황색포도알균과 표피포도알균에 대한 광역학 치료의 항균효과)

  • Kwon, Pil-Seung
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.2
    • /
    • pp.314-321
    • /
    • 2013
  • Photodynamic therapy(PDT) has been recommended as an alternative therapy for various diseases including microbial infection. The aim of the present study is to evaluate the antimicrobial effect of PDT using a photofrin and home made 630 nm Light emitting diode(LED) against Staphylococci. To examine the antimicrobial effect of photofrin-mediated PDT against Staphylococcus aureus and Staphylococcus epidermidis colony forming units(CFU) quantification, and bacterial viability using flow cytometry were formed. The CFU quantification results of S. aureus and S. epidermidis were 1 cfu/ml and 16 cfu/ml of average, respectively, after PDT application with photofrin of $50{\mu}g/m{\ell}$ and 630 nm LED and energy density of $18J/cm^2$. In addition, S. aureus and S. epidermidis isolates yielded forward-scatter (FSC) and fluorescence intensity (FI) differences on flow cytometry (FCM) after PDT. S. aureus and S. epidermidis cell size(FSC) increased 8.96% and 5.55% respectively, after PDT. Also the numbers of dead cell of S. aureus and S. epidermidis were a 39% and 61% incerased. These results suggest that photofrin-mediated PDT can be an effective alternative treatment for antibacterial therapy.

백색 LED증착용 MOCVD 유도가열 장치에서 가스 inlet위치에 따른 기판의 온도 균일도 측정

  • Hong, Gwang-Gi;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.115-115
    • /
    • 2010
  • 고휘도 고효율 백색 LED (lighting emitting diode)가 차세대 조명광원으로 급부상하고 있다. 백색 LED를 생산하기 위한 공정에서 MOCVD (유기금속화학증착)장비를 이용한 에피웨이퍼공정은 에피층과 기판의 격자상수 차이와 열팽창계수차이로 인하여 생성되는 에피결함의 문제로 기판과 GaN 박막층 사이에 완충작용을 해줄 수 있는 버퍼층 (Buffer layer)을 만든다. 그 위에 InGaN/GaN MQW (Multi Quantum Well)공정을 하여 고휘도 고효율 백색 LED를 구현 할 수 있다. 이 공정에서 기판의 온도가 불균일해지면 wafer 파장 균일도가 나빠지므로 백색 LED의 yield가 떨어진다. 균일한 기판 온도를 갖기 위한 조건으로 기판과 induction heater의 간격, 가스의 흐름, 기판의 회전, 유도가열코일의 디자인 등이 장비의 설계 요소이다. 본 연구에서는 유도가열방식의 유도가열히터를 이용하여 기판과 히터의 간격에 차이에 따른 기판 균일도 측정했고, 회전에 의한 기판의 온도분포와 자기장분포의 실험적 결과를 상용화 유체역학 코드인 CFD-ACE+의 모델링 결과와 비교 했다. 또한 가스의 inlet위치에 따른 기판의 온도 균일도를 측정하였다. 본 연구에서 사용된 가열원은 유도가열히터 (Viewtong, VT-180C2)를 사용했고, 가열된 흑연판 표면의 온도를 2차원적으로 평가하기 위하여 적외선 열화상 카메라 (Fluke, Ti-10)를 이용하여 온도를 측정했다. 와전류에 의한 흑연판의 가열 현상을 누출 전계의 분포로 확인하기 위하여 Tektronix사의 A6302 probe와 TM502A amplifier를 사용했다. 흑연판 위에 1 cm2 간격으로 211곳에서 유도 전류를 측정했다. 유도전류는 벡터양이므로 $E{\theta}$를 측정했으며, 이때의 측정 방향은 흑연판의 원주방향이다. 또한 자기장에 의한 유도전류의 분포를 확인하기 위하여 KANETEC사의 TM-501을 이용하여 흑연판 중심으로부터 10 mm 간격으로 자기장을 측정 했다. 저항 가열 히터를 통하여 대류에 의한 온도 균일도를 평가한 결과 gap이 3 mm일때, 평균 온도 $166.5^{\circ}C$에서 불균일도 6.5%를 얻었으며, 회전에 의한 온도 균일도 측정 결과는 2.5 RPM일 때 평균온도 $163^{\circ}C$에서 5.5%의 불균일도를 확인했다. 또한 CFD-ACE+를 이용한 모델링 결과 자기장의 분포는 중심이 높은 분포를 나타냄을 확인했고, 기판의 온도분포는 중심으로부터 55 mm되는 곳에서 300 W/m3로 가장 높은 분포를 나타냈다. 가스 inlet 위치를 흑연판 중심으로 수직, 수평 방향으로 흘려주었을 때의 불균일도는 각각 10.5%, 8.0%로 수평 방향으로 가스를 흘려주었을 때 2.5% 온도 균일도 향상을 확인했다.

  • PDF

Ubiquitous sensor network based plant factory LED lighting system development (유비쿼터스 센서 네트워크 기반의 식물공장 LED 조명 시스템 개발)

  • Yang, Heekwon;Shin, Minseock;Lee, Chankil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.845-848
    • /
    • 2013
  • Due to intense climate changes and extreme weather conditions a noticeable decrease has been observed in the growth of certain plants. The indoor plant factories would have certain benefits including increase in crop yield, reduction in distribution cost, and maintains the healthy freshness level of the agricultural product. Recently, an artificial light source with optimum wavelength is spot lighted to fulfill the need of light for the indoor plant factories. The energy efficient light emitting diodes (LED) provide the essential light energy for the proper growth of indoor cultivated plants. This work focuses to utilize ubiquitous sensors network(USN) in providing suitable environment for the proper growth of agricultural product inside the indoor plant factory. The proposed system makes use of sensors and actuators, communicating each other through WPAN, ZigBee network. The proposed system obscured the traditional indoor plant factories with easy installation and wireless connectivity of the sensors and actuators along with eliminating the web of wires reducing the initial installation and maintenance cost.

  • PDF

Input and Output Characteristics of Input Current Controlled Inverter Arc Welding Machine with High Efficiency (입력전류 제어형 고효율 인버터아크용접시스템의 입력 및 출력 특성연구)

  • 최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.358-369
    • /
    • 2000
  • Shielded metal arc welding machines with AC transformer have been widely used for thin-plate welding applications. Because of being bulky, heavy and of tap-changing property, so the SMAW's are changing to new power electronic circuits such as inverter circuit in order to reduce the system size and also to improve the welding performances at input output sides. The PWM inverter arc welding machine with diode rectifier has better output welding performances but it is has the plentiful harmonics and the lower input power factor. To solve these problems, input current-controlled scheme is considered for PWM inverter arc welding system, and then total input power factor is maintained to be more than 99%. Also a new combined control is proposed which can control both instantaeous welding output voltage and current under constant power condition, and as a result the variations of instantaneous current and voltage can be reduced to very narrow range in the V-I curve relationship, and hence the variance of welding current and voltage become so reduced. In addition the spatter generated during welding process is greatly reduced up to 70%. And the overall effiency can be improved up to 10%, which becomes higher when the load is lower.

  • PDF

THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES (광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구)

  • Ryoo, Joo-Hee;Lee, In-Bog;Yoo, Hyun-Mee;Kim, Mi-Ja;Seok, Chang-In;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

The Effect of Blue and Red LEDs Irradiation on The Growth Characteristics and Ginsenoside Content of Panax ginseng C. A. Meyer (청색과 적색의 혼합LED광 처리가 인삼의 생육 및 진세노사이드 함량에 미치는 영향)

  • Seong, Bong-Jae;Kim, Hyun-Ho;Cho, Jin-Woong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.1
    • /
    • pp.70-74
    • /
    • 2015
  • An LED plant factory farm is an alternative way to grow crops regardless of weather, season, and blight in such times of climate change. In recent years, it is a currently active and vibrant research field. The industry, which ranges from leaf vegetables to high value products, is expanding. This study was conducted to test tthe response of LED (Light-emitting diode) irradiation on the growth characteristics and ginsenoside levels indoors, in order to find out suitable light conditions. Ginseng seedling was transplanted from a styrofoam pot ($L{\times}W{\times}D$:$495{\times}315{\times}215mm$, inside diameter) into a closed plant production system in four blue LED (BL) and red LED (RL) different ratios of 1:1, 1;2, 1:3, 1:4 in a temperature range of $20{\sim}25^{\circ}C$, relative humidity of between 55 and 65%, and a 12-hour photoperiod. The LED irradiation shows the highest levels were found at 1:1 of BL and RL ratio at $61.21{\mu}mol\;s^{-l}m^{-2}$, 1:2 ratio $68.55{\mu}mol\;s^{-l}m^{-2}$, 1:3 ratio $63.85{\mu}mol\;s^{-l}m^{-2}$ and 1:4 ratio $62.41{\mu}mol\;s^{-l}m^{-2}$ from highest to lowest respectively. After analyzing from shoot and root 2 yers old ginseng plant which were cultivated under 1:3 irradiation of BL and RL ratio, it generally showed a positive effect under a 1:3 ratio of BL and RL.

A $2{\times}2$ Microstrip Patch Antenna Array for Moisture Content Measurement of Paddy Rice (산물벼 함수율 측정을 위한 $2{\times}2$ 마이크로스트립 패치 안테나 개발)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.97-106
    • /
    • 2000
  • To develop the grain moisture meter using microwave free space transmission technique, a 10.5GHz microwave signal with the power of 11mW generated by an oscillar with a dielectric resonator is transmitted to an isolator and radiated from a transmitting $2{\times}2$ microstrip patch array antenna into the sample holder filled with the 12 to 26%w.b. of Korean Hwawung paddy rice. the microwave signal, attenuated through the grain with moisture, is collected by a receiving $2{\times}2$ microstrip patch array antenna and detected using a Shottky diode with excellent high frequency characteristic. A pair of light and simple microstrip patch array antenna for measurement of grain moisture content is designed and implemented on atenflon substrate with trleative dielectric constant of 2.6 and thickness of 0.54 by using Ensemble ver. 4.02 software. The aperture of microstrip patch arrays is 41 mm width and 24mm high. The characteristics of microstrip patch antenna such as grain. return loss, and bandwidth are 11.35dBi, -38dB and 0.35GHz($50^{\circ}$ at far-field pattern of E and H plane. The width of the sample holder is large enough to cover the signal between the antennas temperature and bulk density respectively. The calibration model for measurement of grain moisture content is proposed to reduce the effects of fluectuations in bulk density and temperature which give serious errors for the measurements . From the results of regression analysis using the statistically analysis method, the moisture content of grain samples (MC(%)) is expressed in terms of the output voltage(v), temperature (t), and bulk density of samples(${\rho}b$)as follows ;$$MC(%)\;=\;(-3.9838{\times}10^{-8}{\times}v^{3}+8.023{\times}10^{-6}{\times}v^{2}-0.0011{\times}v-0.0004{\times}t+0.1706){\frac{1}{{\rho}b}}{\times}100$ Its determination coefficient, standard error of prediction(SEP) and bias were found to be 0.9855, 0.479%w.b. and -0.0.369 %w.b. respectively between measured and predicted moisture contents of the grain samples.

  • PDF

A survey on pesticide residues of imported fruits circulated in Gyeonggido (경기도내 유통 수입과실류의 잔류농약 실태조사)

  • Cho, Yun-Sik;Kang, Jeong-Bok;Kim, Yang-Hee;Jeong, Jin-A;Huh, Jeong-Weon;Lee, So-Hyun;Lim, Young-Sik;Bae, Ho-Jeong;Kang, Heung-Gyu;Lee, Jeong-Hee;Jung, Eun-Sook;Lee, Byoung-Hoon;Park, Yong-Bok;Lee, Jong-Bok
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • We tested for pesticide residues in 124 samples of 22 different items of imported fruits circulated in Gyeonggido. Total 218 pesticides were analyzed by multi-residue method using gas chromatography/nitrogen phosphorus detector-electron capture detector (GC/NPD-ECD), time of flight/mass spectrometer (TOF/MS), ultra performance liquid chromatography/photo diode array (UPLC/PDA), high performance liquid chromatography/fluorescence detector (HPLC/FLD) and mass spectrometer (LC/MS/MS). The pesticides were detected in 18 fruits samples, ranging 0.003~0.3 mg/kg and no samples had violative residue. The separation test to 14 sample pesticides detected was conducted to monitor the current status of pesticide residues according to the partial characteristic. The pesticides were detected in 14 peels ranging 0.03~1.5 mg/kg and 2 fleshes in less than detection limits. These results indicate that imported fruits are safe when the human takes normally but even the small amount of pesticides is harmful when the human takes it in a prolonged period. Therefore, the pesticide residual amounts of imported friuts should be constantly monitored for food safety.