• Title/Summary/Keyword: Dimensional characteristics

Search Result 5,259, Processing Time 0.039 seconds

Study for making movie poster applied Augmented Reality (증강현실 영화포스터 제작연구)

  • Lee, Ki Ho
    • Cartoon and Animation Studies
    • /
    • s.48
    • /
    • pp.359-383
    • /
    • 2017
  • 3,000 years ago, since the first poster of humanity appeared in Egypt, the invention of printing technique and the development of civilization have accelerated the poster production technology. In keeping with this, the expression of poster has also been developed as an attempt to express artistic sensibility in a simple arrangement of characters, and now it has become an art form that has become a domain of professional designers. However, the technological development in the expression of poster is keep staying in two-dimensional, and is dependent on printing only that it is irrelevant to the change of ICT environment based on modern multimedia. Especially, among the many kinds of posters, the style of movie posters, which are the only objects for video, are still printed on paper, and many attempts have been made so far, but the movie industry still does not consider ICT integration at all. This study started with the feature that the object of the movie poster dealt with the video and attempted to introduce the augmented reality to apply the dynamic image of the movie to the static poster. In the graduation work of the media design major of a university in Korea, the poster of each works for promoting the visual work of the students was designed and printed in the form of a commercial film poster. Among them, 6 artworks that are considered to be suitable for augmented reality were selected and augmented reality was introduced and exhibited. Content that appears matched to the poster through the mobile device is reproduced on a poster of a scene of the video, but the text informations of the original poster are kept as they are, so that is able to build a moving poster looked like a wanted from the movie "Harry Potter". In order to produce this augmented reality poster, we applied augmented reality to posters of existing commercial films produced in two different formats, and found a way to increase the characteristics of AR contents. Through this, we were able to understand poster design suitable for AR representation, and technical expression for stable operation of augmented reality can be summarized in the matching process of augmented reality contents production.

Optimization of Extraction Conditions for Ethanol Extracts from Chrysanthemum morifolium by Response Surface Methodology (반응표면분석에 의한 소국(小菊) 에탄올 추출물의 추출조건 최적화)

  • Park, Nan-Young;Kwon, Joong-Ho;Kim, Hyun-Ku
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.1189-1196
    • /
    • 1998
  • Extraction conditions were optimized using response surface methodology for preparing high-quality ethanol extracts from cultivated Chrysanthemum petals. A fractional factorial design was applied to investigate effects of solvent ratio to sample $(X_1)$, ethanol concentration $(X_2)$ and extraction time $(X_3)$ at $60^{\circ}C$ on dependent variables of the extract properties, such as yellow color $(Y_1)$, carotenoids $(Y_2)$, soluble solids $(Y_3)$, phenolic compounds $(Y_4)$, electron donating ability $(Y_5)$, sensory color $(Y_6)$ and sensory aroma $(Y_7)$. Second-order models were employed to generate 3-dimensional response surfaces for dependent variables and their coefficients of determination $(R^2)$ were ranged from 0.8063 to 0.9963. Optimum extraction conditions for each variable were 115 mL/g, 97%, 18 hr in yellow color, 145 mL/g, 50%, 12 hr in carotenoids, 147 mL/g, 48%, 17 hr in soluble solids, 116 mL/g, 68%, 17 hr in phenolic compounds, 110 mL/g, 98%, 14 hr in electron donating ability, 101 mL/g, 48%, 54 hr in organoleptic color and 109 mL/g, 54%, 4 hr in organoleptic aroma, respectively. The range of optimum conditions at 16hr extraction for maximized characteristics of ethanol extracts was $103{\sim}122\;mL/g$ and $64{\sim}78%$. Predicted values at the optimum condition agreed with experimental values.

  • PDF

The Effect of Manufacturing Method Preferences for Different Product Types on Purchase Intent and Product Quality Perception (제품유형에 따른 제조방식 선호가 구매의도와 품질지각에 미치는 효과)

  • Lee, Guk-Hee;Park, Seong-Yeon
    • Science of Emotion and Sensibility
    • /
    • v.19 no.4
    • /
    • pp.21-32
    • /
    • 2016
  • Studies have observed various phenomena regarding the effect of the interaction between type, price, and brand image of a product on consumers' purchase intent and product quality perception. Yet, few have studied the effect of the interaction between product type and manufacturing method on these factors. However, the advent of three-dimensional (3D) printers added a new manufacturing method, 3D printing, to the traditional methods of handicraft and automated machine-based production, and research is necessary since this new framework might affect consumers' purchase intent and product quality perception. Therefore, this study aimed to verify the effects of the interaction between product type and manufacturing method on purchase intent and product quality perception. To achieve this, in our experiment 1, we selected product types with different characteristics (drone vs. violin vs. cup), and measured whether consumers preferred different manufacturing methods for each product type. The results showed that consumers preferred the 3D printing method for technologically advanced products such as drones, the handmade method for violins, and the automated machine-based manufacturing method, which allows mass production, for cups. Experiment 2 attempted to verify the effects of the differences in manufacturing method preferences for each product type on consumers' purchase intent and product quality perception. Our findings are as follows: for drones, the purchase intent was highest when 3D printing was used; for violins, the purchase intent was highest when the violins were handmade; for cups, the purchase intent was highest when machine-based manufacturing was used. Moreover, whereas the product quality perception for drones did not differ across different manufacturing methods, consumers perceived that handmade violins had the highest quality and that cups manufactured with 3D printing had the lowest quality (the purchase intent for cups was also lowest when 3D printing was used). This study is anticipated to provide a wide range of implications in various areas, including consumer psychology, marketing, and advertising.

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

Three-Dimensional Finite Element Analysis of Internal Connection Implant System (Gsii$^{(R)}$) According to Three Different Abutments and Prosthetic Design (국산 내부연결형 임플란트시스템(GS II$^{(R)}$)에서 지대주 연결방식에 따른 응력분석에 관한 연구)

  • Jang, Mi-Ra;Kwak, Ju-Hee;Kim, Myung-Rae;Park, Eun-Jin;Park, Ji-Marn;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.179-195
    • /
    • 2010
  • In the internal connection system, the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. The purpose of this study was to assess the loading distributing characteristics of three different abutments for GS II$^{(R)}$ implant fixture(Osstem, Korea) under vertical and inclined loading using finite element analysis. Three finite element models were designed according to three abutments; 2-piece Transfer$^{TM}$ abutment made of pure titanium(GST), 2-piece GoldCast$^{TM}$ abutment made of gold alloy(GSG), 3-piece Convertible$^{TM}$ abutment with external connection(GSC). This study simulated loads of 100N in a vertical direction on the central pit(load 1), on the buccal cusp tip(load 2) and $30^{\circ}$ inward inclined direction on the central pit(load 3), and on the buccal cusp tip(load 4). The following results were obtained. 1. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture and lower stress was taken at the cancellous bone. 2. When off-axis loading was applied, high stress concentration observed in cervical area. 3. GSG showed even stress distribution in crown, abutment and fixture. GST showed high stress concentration in fixture and abutment screw. GSC showed high stress concentration in fixture and abutment. 4. Maximum von Mises stress in the surrounding bone had no difference among three abutment type. In GS II$^{(R)}$ conical implant system, different stress distribution pattern was showed according to the abutment type and the stress-induced pattern at the supporting bone according to the abutment type had no difference among them.

A Study on Expressing 3D Animation by Visual Direction : focused on 〈 How to train your dragon 〉 (시각적 연출에 의한 3D 입체 애니메이션 표현 연구: 〈드래곤 길들이기〉를 중심으로)

  • Kim, Jung-Hyun
    • Cartoon and Animation Studies
    • /
    • s.26
    • /
    • pp.1-30
    • /
    • 2012
  • The purpose of animation is to give interesting stories to an audience through motion. To achieve the purpose, over the past century since its inception, animation has adopted many kinds of technologies, and thus developed diverse narrative methods and visual expression techniques. In addition, with the advancement of expression techniques, all elements making up animation have gradually been systemized, and at the same time, have helped express the worlds beyond the reality. As a result, people have faced the era when an audience can watch everything imaginated by an animation director on a big screen. These days, more efforts have been made in order for the audience to feel much more than enjoy pictures moving in a frame. In other words, the purpose of the animation is changing from the passive viewing of animation to feeling and sensing stuffs through the animation. In the center of the changing process is 3D technology which gives new interesting to an audience. Sometime ago, a 3D animation movie was produced in Korea. But it did not bring out box-office profits, for it failed to give satisfaction to an audience who expected high perfection and beauty being able to be rivalled to those of international 3D animation movies. The failure is attributable to the fact that the domestic 3D animation production industry is merely in the early stage, and has not sufficient human resources, technology, and experiences in producing 3D animation films. Moreover, the problem is that most studies on 3D focus on the technologies related to reenactment, but that few studies on the images, which an audience directly faces, have been conducted. Under the domestic circumstance, the study on stereoscopic image screen of , a 3D stereoscopic animation film which was released in 2010 and has been seen as the best successful 3D stereoscopic animation, is worthwhile. Thus this thesis conducted theoretical consideration and case analysis focusing on the visual direction that creates the pictures to deliver abundant three dimensional effect so that it can be used as a basic data when producing high quality-domestic 3D animation and training professional labor forces. In the result, it was found that the 3D animation was not a new area, but the area which has been expanded and changed by applying the characteristics of 3D image based on the principles of the existing media aesthetics. This study might be helpful to establish the foundation of the theoretical studies necessary for producing 3D animation contents for realizing the sense of reality.

A Posteroanterior Cephalometric Study on Craniofacial Proportions of Koreans with Normal Occlusion (한국인 정상 교합자의 정모 두부 방사선 사진을 이용한 안모비율에 관한 연구)

  • Baik, Hyoung-Seon;Yu, Hyung Seog;Lee, Kie-Joo
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.643-659
    • /
    • 1997
  • For the total treatment of skeletal malocclusions, 3-dimensional evaluation and diagnosis are essential. Although anteroposterior discrepancies can be evaluated through various methods, the satisfactory methods for evaluations of facial asymmetry and transverse discrepancies are yet to be found. The adequate diagnosis and treatment of transverse discrepancies may be more important in the maintenance of functional occlusion as well as for the stability of results obtained from orthognathic surgery than the anteroposterior or vertical discrepancies. Since the soft tissue effects from the transverse discrepancies may not be pronounced, especially when combined with anteroposterior or vertical discrepancies which have prominent characteristics, the differentiation of their effects may be difficult from visual inspection alone. Therefore it is essential that the normal facial proportions would be established from the posteroanterior cephalometry as a reference for the accurate diagnosis and treatment. The present study evaluates 76 subjects from Yonsei University freshmen with normal facial symmetry and occlusion. Posteroanterior cephalograms were taken from the subjects and the normal values and facial proportions are obtained. The results are as follows. 1. The transverse and vortical values from posteroanterior cephalometry and their ratio, with means and standard deviations are calculated. 2. The ratio of vertical values to transverse values is 0.837 (male 0.836, female 0.841). 3. The Proportion of maxillary and mandibular widths is 0.747 (male 0.745, female 0.752), with statistically significant correlation. 4. Various degree of significant correlations are observed in the following craniofacial widths; (Cranial width, Bizygomaticofrontal suture width, Facial width, Maxillary width, Upper & Lower Intermolar width, Mandibular width). 5. Although the facial height as well as other line measurements increase as the facial widths increase, angle measurement ($Bj\ddot{o}rk$ Sum, Mandibular Plane Angle, Gonial Angle), decreases and posterior to anterior facial height ratio increases, therefore indicating the tendency for a brachycephalic facial type. These results may be used as references for the treatment planning in orthognathic and orthodontic treatments for the dentofacial deformity patients.

  • PDF

Antioxidant Activity of Ethanol Extraction on Citron Seed by Response Surface Methodology (반응표면분석에 의한 유자씨 에탄올 추출물의 항산화활성)

  • Woo, Koan-Sik;Jeong, Ji-Young;Hwang, In-Guk;Lee, Yoon-Jeong;Lee, Youn-Ri;Park, Hee-Jeong;Park, Eui-Seok;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.3
    • /
    • pp.384-390
    • /
    • 2009
  • Extraction characteristics of citron (Citrus junos Sieb. ex Tanaka) seeds and functional properties of corresponding extract were monitored by response surface methodology (RSM). Maximum extraction yield of 20.23% was obtained at extraction temperature of $50.23^{\circ}C$, extraction time of 3.03 hr, and shaking velocity of 400.06 rpm. At extraction temperature, extraction time, and shaking velocity of $49.88^{\circ}C$, 2.72 hr, and 400.39 rpm, respectively, maximum polyphenol content was 4.37 mg/g. At extraction temperature, extraction time, and shaking velocity of $50.28^{\circ}C$, 3.42 hr, and 399.96 rpm, respectively, maximum electron donating ability (EDA) was 49.69%. Maximum nitrite scavenging activity (NSA) was 47.79% at extraction temperature, extraction time, and shaking velocity of $49.19^{\circ}C$, 0.68 hr, and 602.95 rpm, respectively. Based on superimposition of 3-dimensional RSM with respect to extraction yield, polyphenol, EDA, and NSA, optimum ranges of extraction conditions were extraction temperature of $50^{\circ}C$, extraction time of about 3 hr, and shaking velocity of 400 rpm.

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.