• 제목/요약/키워드: Dimensional Verification

검색결과 510건 처리시간 0.021초

Two-Dimensional Joint Bayesian Method for Face Verification

  • Han, Sunghyu;Lee, Il-Yong;Ahn, Jung-Ho
    • Journal of Information Processing Systems
    • /
    • 제12권3호
    • /
    • pp.381-391
    • /
    • 2016
  • The Joint Bayesian (JB) method has been used in most state-of-the-art methods for face verification. However, since the publication of the original JB method in 2012, no improved verification method has been proposed. A lot of studies on face verification have been focused on extracting good features to improve the performance in the challenging Labeled Faces in the Wild (LFW) database. In this paper, we propose an improved version of the JB method, called the two-dimensional Joint Bayesian (2D-JB) method. It is very simple but effective in both the training and test phases. We separated two symmetric terms from the three terms of the JB log likelihood ratio function. Using the two terms as a two-dimensional vector, we learned a decision line to classify same and not-same cases. Our experimental results show that the proposed 2D-JB method significantly outperforms the original JB method by more than 1% in the LFW database.

역설계를 위한 인터넷 기반의 치수검증 시스템 (An Internet-based Dimensional Verification System for Reverse Engineering)

  • 송인호;김경돈;정성종
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1409-1417
    • /
    • 2003
  • In the 21st century, the concept of remote design and manufacture is strongly required in manufacturing processes to reduce cost and time-to-market. The objective of this paper is the development of an internet-based dimensional verification system for reverse engineering. An inspection client can register measurement data at the developed web server. Collaborators related to the development of a new product can confirm geometrical form from measurement data, check dimensional information and mark up the important parts, as well as make a statement of their views through the Internet. The developed system is realized through the ActiveX-Server architecture. Functions of the dimensional verification module are constructed as ActiveX by using the visual C++ and OpenGL. The usefulness of the developed system is confirmed through a case study.

엔드밀링의 효과적인 절삭력 모델과 NC 검증시스템으로의 응용 (Fast Force Algorithm of End Milling Processes and Its Application to the NC Verification System)

  • 김찬봉;양민양
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1555-1562
    • /
    • 1995
  • This study represents the non-dimensional cutting force model. With the non-dimensional cutting force model it is possible to estimate efficiently the maximum cutting force during one revolution of cutter. Using the non-dimensional cutting force model, the feed rate and spindle speed are adjusted so as to satisfy the maximum cutting force and maximum machining error. To verify the accuracy and efficiency of the non-dimensional cutting force model, a series of experiments were conducted, and experimental results proved and verified the non-dimensional cutting force model. The NC toolpath verification system developed in this paper uses the non-dimensional cutting force model, so that it is effective for calculating the cutting force and adjusting the cutting conditions.

STEP 파일을 이용한 웹기반 설계 및 치수 검증 시스템 (Web-based Design and Dimension Verification System Using STEP Files)

  • 송인호;정성종
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.961-969
    • /
    • 2004
  • Most manufacturing companies are trying to develop a competitive product by increasing the quality, shortening time to market and reducing the cost of a product. Collaborators related to the development of a new product want to confirm geometric forms and dimensions during the design process, as well as to verify dimensional errors of a product during the fabrication process. Objective of this paper is the development of a collaborative design and dimension verification system on the Internet. STEP files obtained from the design process are used for the design and dimension verification. Functions of the design and dimension verification modules are constructed over the ActiveX control using the visual C/sup ++/ and OpenGL. By using mark up functions over the Internet, collaborators check geometries, interferences, dimensional errors, human factors and form errors, as well as share their design ideas and opinions with XML rapidly and remotely. The usefulness of the developed system is confirmed through case studies.

웹기반 협업을 위한 치수검증이 가능한 경량캐드파일 설계 (Design of Lightweight CAD Files with Dimensional Verification Capability for Web-Based Collaboration)

  • 송인호;정성종
    • 대한기계학회논문집A
    • /
    • 제30권5호
    • /
    • pp.488-495
    • /
    • 2006
  • The demand for the use of 3D CAD data over the Internet environment has been increased. However, transmission of 3D CAD data has delayed the communication effectiveness because of the CAD data size. Lightweight CAD file design methodology is required for rapid transmission in the distributed environment. In this paper, to derive lightweight CAD files from commercial CAD systems, a file translation system producing a native file is constructed first by using the InterOp and API of the ACIS kernel. Using the B-rep model and mesh data extracted from the native file, the lightweight CAD file with topological information is constructed as a binary file. Since the lightweight CAD file retains topological information, it is applied to the dimensional verification, digital mock-ups and visualization of CAD files. Effectiveness of the proposed lightweight CAD file is confirmed through various case studies.

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

일반 필기 데이터를 이용한 온라인 서명 검증 기법 (Online Signature Verification Method using General Handwriting Data)

  • 허경용;김성훈;우영운
    • 한국정보통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.2298-2304
    • /
    • 2017
  • 온라인 서명 검증은 간단하면서도 효율적인 본인 확인 방법의 하나로 다른 생체 인식 기술에 비해 거부감이 적은 장점이 있다. 서명 검증 모델을 학습하기 위해서는 모조서명이 필요하지만 대부분의 실용적인 응용에서는 모조서명을 확보하기가 쉽지 않다. 이 논문에서는 이러한 모조서명 확보 문제를 해결할 수 있는 방법의 하나로 다른 사람의 서명을 활용하는 방법을 제시한다. 검증 과정에서는 서명의 형태적 특징을 추출하고 이를 SVM을 이용하여 검증하였다. SVM은 특징 벡터를 고차원으로 사상하고 사상된 공간에서 선형 분리를 시도하는 방법으로 인식기 중 범용적이면서 높은 성능을 보이는 것으로 알려져 있다. 모델 생성 과정에서 모조서명으로 검증하고자 하는 사람의 서명과 형태적인 유사점을 찾을 수 없는 서명, 즉, 일반 필기 데이터를 사용함으로써, 모조서명의 확보가 어려운 경우에도 검증률을 개선할 수 있음을 실험 결과를 통해 확인할 수 있으며, 이는 모조서명 없이도 서명 검증이 가능함을 보여준다.

DEVELOPMENT AND PRELIMINARY ASSESSMENT OF A THREE-DIMENSIONAL THERMAL HYDRAULICS CODE, CUPID

  • Jeong, Jae-Jun;Yoon, Han-Young;Park, Ik-Kyu;Cho, Hyoung-Kyu;Lee, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.279-296
    • /
    • 2010
  • For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been developed. The CUPID code adopts a two-fluid, three-field model for two-phase flows, and the governing equations were solved over unstructured grids, which are very useful for the analysis of flows in complicated geometries. To obtain numerical solutions, the semi-implicit numerical method for the REALP5 code was modified for an application to unstructured grids, and it has been further improved for enhanced accuracy and fast running. For the verification of the CUPID code, a set of conceptual problems and experiments were simulated. This paper presents the flow model, the numerical solution method, and the results of the preliminary assessment.

이차원 비대칭형 초음속 노즐 설계와 실험적 검증 (Design and Experimental Verification of Two Dimensional Asymmetric Supersonic Nozzle)

  • 김채형;성근민;정인석;최병일
    • 한국항공우주학회지
    • /
    • 제37권9호
    • /
    • pp.899-905
    • /
    • 2009
  • 일반적으로 초음속 유동 실험 장치에는 축대칭형 노즐이나 이차원 대칭형 노즐이 사용되고 있다. 하지만, 이차원 비대칭형 초음속 노즐은 상대적으로 가공비용이 저렴하며 노즐의 결합부에서 생기는 불필요한 충격파 생성을 줄일 수 있는 이점이 있다. 본 논문에서는 초음속 혼합기의 연소 실험을 위해 마하수 2의 비대칭 초음속 노즐을 설계하였다. 특성곡선해법을 이용하여 설계된 노즐에 대하여 수치해석을 수행하여 경계층보정을 하였으며 최종적으로 가공된 노즐에 대하여 마하파를 가시화 하는 실험을 통하여 노즐의 성능을 검증하였다. 이를 통하여 2차원 비대칭형 초음속 노즐의 설계와 검증 방법을 제시하였다.

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF