• 제목/요약/키워드: Dilution of Precision

Search Result 114, Processing Time 0.023 seconds

The Effect of Altitude Errors in Altitude-aided Global Navigation Satellite System(GNSS) (고도를 고정한 GNSS 위치 결정 기법에서 고도 오차의 영향)

  • Cho, Sung-Lyong;Han, Young-Hoon;Kim, Sang-Sik;Moon, Jei-Hyeong;Lee, Sang-Jeong;Park, Chan-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1483-1488
    • /
    • 2012
  • This paper analyzed the precision and accuracy of the altitude-aided GNSS using the altitude information from digital map. The precision of altitude-aided GNSS is analysed using the theoretically derived DOP. It is confirmed that the precision of altitude-aided GNSS is superior to the general 3D positioning method. It is also shown that the DOP of altitude-aided GNSS is independent of altitude bias error while the accuracy was influenced by the altitude bias error. Furthermore, it is shown that, since the altitude bias error influenced differently to each pseudorange measurement, the effect of the altitude bias error is more serious than clock bias error which does not influence position error at all. The results are evaluated by the simulation using the commercial RF simulator and GPS receiver. It confirmed that altitude-aided GNSS could improve not only precision but also accuracy if the altitude bias error are small. These results are expected to be easily applied for the performance improvement to the land and maritime applications.

Analysis of Network-RTK(VRS) Positioning Accuracy for Surveying Public Control Point (공공기준점 측량에 적용을 위한 VRS(가상기준점) 방식의 Network-RTK 정확도 분석)

  • Han, Joong-Hee;Kwon, Jay-Hyoun;Hong, Chang-Ki
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • Currently, NGII(National Geographic Information Institute) provides VRS(Virtual Reference System) service using 44 CORS(Continuously Operating Reference Stations). Since the VRS provides high-precision coordinate in a short time, the users and applications are expected to be rapidly increasing. The accuracy analysis on the VRS service, however, was not sufficiently performed yet. Therefore, in this study, the VRS data is acquired from various circumstances and its accuracy is analyzed. According to analysis, it was concluded that the VRS could be applied to public control point survey. Furthermore, it was found that the PQ(Position Quality) which represents variance of estimated coordinates rather than GDOP(Geometric Dilution of Precision) is more relevant as a factor to determine the accuracy of coordinates. Based on the analysis of data from four manufacturers (TRIMBLE, MAGELLAN, LECIA, TOPCON), it was confirmed that the standard deviations better than 3cm. Therefore, VRS Survey apply to public control point survey.

Development and validation of enzyme-linked immunosorbent assay for anti-mouse pertussis immunoglobulin G using international reference anti-Bordetella pertussis mouse serum NIBSC 97/642

  • Kyu-Ri Kang;Yi-Hyeon Kwon;Gyu-Won Cho;Gi-Sub Choi;Joon-Hwan Ji;Hyun-Mi Kang;Soo-Young Lee;Jin-Han Kang
    • Clinical and Experimental Vaccine Research
    • /
    • v.13 no.3
    • /
    • pp.242-252
    • /
    • 2024
  • Purpose: In this study, an in-house enzyme-linked immunosorbent assay (ELISA) was developed and validated. The titer of ELISA was calculated using the reference line (RFL) method based on the standard curve drawn using the international reference anti-mouse serum NIBSC (National Institute for Biological Standards and Control) 97/642. Materials and Methods: In the development step, signal to noise was depicted to select the buffers that showed the most appropriate ratio. In the validation step, standard range, precision, dilution linearity, and specificity were confirmed, and RFL and parallel line (PLL) methods were compared in precision and dilution linearity. Results: Coating concentration for plate was achieved at 0.1 ㎍/mL for pertussis toxin (PT), 0.15 ㎍/mL for filamentous hemagglutinin antigen (FHA), and 0.25 ㎍/mL for pertactin (PRN). The signal to noise ratio was 22.02 for PT, 14.93 for FHA, and 8.02 for PRN with 0.25% goat serum in phosphate-buffered saline (PBS) as a dilution buffer, and 2% skim milk in PBS as a blocking buffer. Based on the precision results, we assessed the lower limit of quantification by 1, 0.2, and 1.5 EU/mL concentration for PT, FHA, and PRN which met the ICH (International Council for Harmonization) M10 criteria of a 25% accuracy and total error of 40%. In specificity, homologous serum was spiked into heterologous serum and the accuracy met the criteria. There was no difference in the results between RFL and PLL calculations (p-value=0.3207 for PT, 0.7394 for FHA, 0.2109 for PRN). Conclusion: ELISA validated with RFL calculation method in this study is a relatively accurate assay for mouse humoral immunogenicity test.

Position DOP Analysis for Sensor Placement in the TDOA-based Localization System

  • Lim, Deok-Won;Kang, Hee-Won;Lee, Sang-Jeong;Hwang, Dong-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.1009-1013
    • /
    • 2012
  • A relationship between the sensor placement and the PDOP (Position Dilution of Precision) is derived in the TDOA-based localization system. And the geometric condition of the sensor placement is analyzed in order to get a minimum PDOP based on the derived relationship. Through computer simulations, effect of the sensor placement on the PDOP is observed.

Analysis of HDOP for RF navigation transmitters on the ground (지상에 배치된 전파항법 신호원의 거리오차 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Young-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.649-651
    • /
    • 2011
  • 본 논문은 지상에 배치된 전파항법신호원의 배치에 따른 거리측정 정확도 분석에 대한 연구이다. 전파항법신호원의 배치 형태에 따른 수신기에서의 수평 측위 정확도(HDOP, Horizontal Dilution of Precision)를 제시하였다. 본 논문에서는 다양한 배치에 따른 측위 정확도를 이론적인 연구결과를 이용하여 분석한 결과를 제시하였다. 또한 전파항법신호원의 배치를 위한 시뮬레이터를 구현하였다.

  • PDF

Zirconia Ceramic Powder Coating of Ti-6AI-4V by Laser Cladding (레이저 클래딩을 이용한 Ti-6AI-4V의 Zirconia 세라믹 분말 코팅)

  • Kang, Kyung-Ho;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.783-788
    • /
    • 2011
  • The recent development of bio-ceramic material is being studied in various bio-material engineering field. There are lots of technical difficulties because manufacturing or bonding technique are required bio-friendliness, cleanliness and persistence. Zirconia ceramic powder is cladded on Ti-6AI-4V metallurgically by laser cladding processing. Laser cladding system with powder feeding delivery is designed and manufactured for optimum processing condition. Increasing of manufacturing speed and good quality of clad layer are achieved by application of preheating of substrate before laser cladding. The thin dilution and good clad layer on the substrate are obtained for applications of bio-materials such as the dental materials and the articulated joints of human body.

Performance Analysis of Long Baseline Relative Positioning using Dual-frequency GPS/BDS Measurements

  • Choi, Byung-Kyu;Yoon, Ha Su;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.8 no.2
    • /
    • pp.87-94
    • /
    • 2019
  • The Global Navigation Satellite System (GNSS) Real-Time Kinematic (RTK) positioning has been widely used in geodesy, surveying, and navigation fields. RTK can benefit enormously from the integration of multi-GNSS. In this study, we develop a GPS/BeiDou Navigation Satellite System (BDS) RTK integration algorithm for long baselines ranging from 128 km to 335 km in South Korea. The positioning performance with GPS/BDS RTK, GPS-only RTK, and BDS-only RTK is compared in terms of the positioning accuracy. An improvement of positioning accuracy over long baselines can be found with GPS/BDS RTK compared with that of GPS-only RTK and that of BDS-only RTK. The positioning accuracy of GPS/BDS RTK is better than 2 cm in the horizontal direction and better than 5 cm in the vertical direction. A lower Relative Dilution of Precision (RDOP) value with GPS/BDS integration can obtain a better positional precision for long baseline RTK positioning.

Development of A Laser Cladding Process Monitoring System (I) -Extraction of optimal process variables (레이저클래딩 공정 모니터링 시스템 개발 (I) - 최적공정변수 추출)

  • 오기석;윤길상;조명우;김문기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.89-92
    • /
    • 2000
  • Laser claddmg 1s thc deposition of material on the surface of a part or workpiece. Cladding of metals produces a 100% dense metallurgically-bonded coating with minimal dilution for enhanced corrosion, abrasion and wear resistance. Despite of minimal heat Input and reduced processing time, cladding quality 1s affected by various process condition such as laser power and feed rate. Therefore, it is necessary to develop the momtoring and control methods of laser cladding process for the best cladding quality. In this paper, laser cladding monitoring system using CCD camera for measuring cladding pool shape, and photo-diode sensor for detecting optical signal emitted from the cladding front is introduced The variables extracted using this system can be apphed to control the laser cladding system to achieve the best claddmg results..

  • PDF

AP Selection Criteria for UAV High-precision Indoor Positioning based on IEEE 802.11 RSSI Measurement (IEEE 802.11 RSSI 기반 무인비행로봇 실내측위를 위한 AP 선택 기법)

  • Hwang, Jun Gyu;Park, Joon Goo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.12
    • /
    • pp.1204-1208
    • /
    • 2014
  • As required performance of UAV (Unmanned Aerial Vehicle) becomes more complex and complicated, required positioning accuracy is becoming more and more higher. GPS is a reliable world wide positioning providing system. Therefore, UAV generally acquires position information from GPS. But when GPS is not available such as too weak signal or too less GPS satellites environments, UAV needs alternative positioning system such as network positioning system. RSSI (Received Signal Strength Indicator) based positioning, which is one method of network positioning technologies, determines its position using RSSI measurements containing distance information from AP (Access Point)s. In that method, a selected AP's configuration has strong and tight relationship with its positioning errors. In this paper, for, we additionally account AP's configuration information by adopting DOP (Dilution of Precision) into AP selection procedures and provide more accurate RSSI based positioning results.

Wear Characteristics of Submerged-Arc Cladding (서브머지드 아크 클래딩에 의한 표면 피복층의 마모특성)

  • 김권흡;권오양
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.179-186
    • /
    • 2003
  • This paper is to investigate the wear behavior of submerged-arc claddings by the wear test with a ball-on-disk type wear testing machine in air. The specimens were clad with Stoody105 alloy wire on a medium carbon steel (SM45C) substrate by submerged-arc cladding process under different welding parameters. The wear behavior of the cladding through ball-on-disk test has been studied under the wear load from 5 to 16 N and the sliding speed from 8 to 35 cm/s. The weight loss of the specimen was measured. Scanning electron micrographs of the worn surface show a layer of oxide film formed on the worn surface. Oxidation wear mechanism controls the wear process. The spatting of the oxide is caused by the repeated rubbing fatigue mechanism.