• Title/Summary/Keyword: Dilution Zone

Search Result 92, Processing Time 0.03 seconds

A Study of factor analysis of immune building system for microbiological safety (실내 미생물 안전을 위한 면역건물기술 인자들의 상호작용에 관한 연구)

  • Choi, Sang-Gon;Jang, Sung-Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.85-92
    • /
    • 2012
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program contam2.4. This model include immune building system(disinfection system) which is consist of dilution, Filter Technology and UVGI(ultra violet germicidal irrdiation). In this study experiments design method used for estimating interaction of HRV air change rate, UVGI air change rate and UVGI grade. Result show that HRV air change rate and UVGI air change rate is most influence factor for remove rate. also Interaction of HRV air change rate and UVGI air change rate is ost influence factor for remove rate.

A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter (고효율 항균 필터의 항균력 평가에 관한 연구)

  • 권혁구;정진도;류해열;정우성;박덕신
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

Hard, Wear Resistant Metal Surfaces for Industrial Applications through Laser Powder Deposition

  • Sears, James;Costello, Aaron
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.293-294
    • /
    • 2006
  • Laser Powder Deposition (LPD) is a technology capable of modifying a metallic structure by adding the appropriate material to perform a desired function. LPD offers a unique fabrication technique that allows the use of soft (tough) materials as base structures. Through LPD a hard material can be applied to the base material with little thermal input (minimal dilution and heat-affected-zone {HAZ}), thus providing the function of a heat treatment or other surface modifications. These surface modifications have been evaluated through standard wear testing (ASTM G-65), surface hardness (Rc), micro-hardness (vickers), and optical microscopy.

  • PDF

The study on the multizone modeling for preventing transmission of air borne contagion (실내 미생물오염 전파방지를 위한 멀티죤 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.429-435
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 which is developed by NIST is used for modeling the air disinfection system which is consist of dilution, filtration, ultra violet germicidal irradiation (UVGI) for removing the indoor microorganism such as bacteria and fungus. Developed models those protect occupants against indoor microorganism generated in our daily life are enable to use for immune building simulation tool. Also, results indicate that those models are enable to compute the real situation that is almost impossible of carrying out experiment and identify the disinfection rate with highly reliance. Results also suggest that engineers will use these models as a design tool for the immune building system.

  • PDF

Variations of Calcium, Bicarbonate, and Cation in the Lacustrine Zone by Interannual Differences in Up-River Discharge

  • An, Kwang-Guk;Lee, Jae-Hoon;Han, Jeong-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.4
    • /
    • pp.471-476
    • /
    • 2010
  • Monthly up-river discharge in the riverine zone analysis resulted in large interannual variations and differences in calcium ($Ca^{2+}$), bicarbonate ($HCO_3^-$), and cations in the lacustrine zone (Lz) of Daecheong Reservoir during the wet year (Wy, 1993) vs. dry year (Dy, 1994). Total up-river discharge in the Wy was four times that of the Dy, and the up-river discharge in July~August of the Wy was eight times greater than that of same period of Dy. Annual water retention time in the Lz showed large difference between the two years. Water residence time (WRT) was minimum when the up-river discharge peaked, whereas the WRT was maximum when the up-river discharge was at minimal condition. This peak discharge from the up-river on early July reduced residence time in the Lz on mid-July~late July. Monthly pattern, based on data of May~November, was similar between the two years, but, but mean retention time in the Wy was 50 days shorter than in the Dy. Such hydrology, up-river discharge, and WRT reduced $Ca^{2+}$, $HCO_3^-$, and cations in the Lz. At low up-river discharge in Wy during April~May, the cation content of Ca+Mg+Na+K averaged 1.17meq $L^{-1}$ (range=1.09-1.26meq $L^{-1}$), but as the up-river discharge increased suddenly, the values decreased. Seasonal fluctuations of $Ca^{2+}$ showed exactly same pattern with bicarbonate ion of $HCO_3^-$. The minimum $Ca^{2+}$ (0.03meq $L^{-1}$) was occurred in the early August of wet year and coincided with the minimum $HCO_3^-$. These results suggest that the magnitude of variation in $Ca^{2+}$, bicarbonate, and cations in the lacustrine zone is directly determined by the peak magnitude of up-river discharge. The magnitude of up-river discharge determined water retention time and the magnitude of ionic dilution in the lacustrine zone, resulting in functional changes of the ecosystem.

Estimation of Antibacterial Properties of Chlorophyta, Rhodophyta and Haptophyta Microalgae Species

  • Imran Bashir, Khawaja Muhammad;Lee, Jae-Hyeon;Petermann, Maike Julia;Shah, Abid Ali;Jeong, Su-Jin;Kim, Moo-Sang;Park, Nam-Gyu;Cho, Man-Gi
    • Microbiology and Biotechnology Letters
    • /
    • v.46 no.3
    • /
    • pp.225-233
    • /
    • 2018
  • In this exploratory study, eight types of microalgae from different phyla (Chlamydomonas reinhardtii, Chlorella species, Haematococcus pluvialis, Porphyridium purpureum, Porphyridium cruentum, Isochrysis species, Isochrysis galbana, and Pavlova lutheri) were tested for their antibacterial activities against eight target pathogenic bacterial strains. The agar well diffusion method and broth micro dilution assay were conducted to estimate the antibacterial activity. Microalgae cell-free supernatants, exopolysaccharides (EPS), water, and organic solvent extracts were used for inhibition analysis. EPS extracted from P. lutheri showed activity against Bacillus subtilis and Pseudomonas aeruginosa. Inhibition zone diameters of 14-20 mm were recorded on agar plates, while the minimum inhibitory concentrations in the broth micro dilution assay were $0.39-25mg\;ml^{-1}$. During this study, haptophyte microalgae, Isochrysis species, and P. lutheri extracts showed the highest activity against most of the tested pathogenic bacterial strains, while most of the extracts were active against the important foodborne pathogen P. aeruginosa. This study showed promising results regarding important microalgae phyla, which will further aid research related to extracts and exploitation of bioactive metabolic compounds in the food and pharmaceutical industries.

Variation of Calcium Carbonate Content and Dansgaard-Oeschger Events in the Continental Slope of the Central Bering Sea during the Last 65 Kyr (베링해 중부 대륙사면 지역의 지난 65,000년 동안 탄산염 함량 변화와 Dansgaard-Oeschger 사건들)

  • Kim, Sung-Han;Khim, Boo-Keun;Itaki, Takuya;Shin, Hye-Sun
    • Ocean and Polar Research
    • /
    • v.30 no.3
    • /
    • pp.215-224
    • /
    • 2008
  • A piston core (MR06-04 PC23A) collected from the northern continental slope in the central Bering Sea has recorded the high-resolution millennial-scale variation of calcium carbonate ($CaCO3$) content during the last 65 kyr. An estimation of the age of the core sediments was carried out by using the lithologic correlation of the deglacial laminated layers with a neighboring core (HLY02023JPC), complementing the last appearance datum of both Lychnocanoma nipponica sakaii (54 kyr) and Amphimelissa setosa (85 kyr). The probable age of core MR06-04 PC23A was approximately younger than 65 kyr. Two distinct events of a significant increase of $CaCO3$ in the deglacial laminated sediments clearly correspond to MWP1A and MWP1B in the Bering Sea (Gorbarenko et al. 2005) and to T1ANP and T1BNP in the North Pacific (Gorbarenko 1996). These pronounced peaks of $CaCO3$ contents result from the elevated carbonate production in the surface water and the subsequent weakened dilution due to terrestrial input, along with an enhanced oxygen minimum zone. The $CaCO3$ contents are low (${\sim}2%$) during the last glacial period mainly because of a low carbonate production caused by an expanded sea-ice cover and an increased dilution by terrigenous particles due to their closer distance to the continent during the sea-level low stand. The occurrence of seven distinct $CaCO3$ peaks in core MR06-04 PC23A is remarkable during MIS 3 and MIS 4, and they most likely correlate to the short-term millennial Dansgaard-Oeschger events.

An Analysis on Influences of Seasonal and Tidal Changes to Outfall Design and Management (조석이 방류관의 설계 및 운영에 미치는 영향 분석)

  • Kim, Ji-Yeon;Lee, Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.28 no.3
    • /
    • pp.259-268
    • /
    • 2004
  • For the last years, it has become hot issue such as disposal of the treated wastewater, which caused by increment of a population and industrial development at the coastal areas. The ocean outfall system discharges primary or secondary treated effluent into coastline or at the deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the see, surface forming plume or jet, together with entraining the surrounding salt water and becomes very dilute. This paper deals ocean outfall design which effects to decision-making about marine environment management and wastewater treatment. In order to make predictions of dilution of discharged water and the trajectory of a plume, CORMIX has been used considering several elements including a seasonal and tidal changes. These solutions are strung together to provide basic data and general drawings for effective management of outfall.

A numerical study of the air fuel ratio effect on the combustion characteristics in a MILD combustor (공연비 변화가 MILD 연소 특성에 미치는 영향에 관한 해석적 연구)

  • Ha, Ji-Soo;Kim, Tae-Kwon;Shim, Sung-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.587-592
    • /
    • 2010
  • A numerical analysis of reactive flow in a MILD(Moderate and Intense Low oxygen Dilution) combustor is accomplished to elucidate the characteristics of combustion phenomena in the furnace with the variation of air fuel ratio. For the smaller magnitude of air injection velocity(10 m/s), the air flow could not penetrate toward upper part of furnace. On the other hand, the air flow suppresses the fuel flow for the case of air injection velocity 30 m/s. The air velocity 18 m/s is corresponding to the stoichiometric air flow velocity, and for that case, the air flows to relatively more upper part of the furnace when compared with the case of air injection velocity 10 m/s. The reaction zone is produced with the previous flow pattern, so that the reaction zone of the air injection velocity 10 m/s is biased to the air nozzle side and for the case of air injection velocity 30 m/s, the reaction zone is inclined to the fuel nozzle side. For the cases with the air injection velocities 16, 18, 20 m/s, the reaction zone is nearly located at the center between air nozzle and fuel nozzle. The maximum temperatures and NOx concentrations for the cases of air injection velocity 16, 18, 20 m/s are lower than the cases with air injection velocity 10, 30 m/s. From the present study, the stoichiometric air fuel ratio is considered as the most optimal operating condition for the NOx reduction.

Comparison of clad layer characteristics with overlapping criterion in multi pass laser cladding (멀티패스 레이저 클래딩에 있어서 중첩률의 기준에 따른 클래드 층의 특성 비교)

  • Kim, Jong-Do;Lee, Eun-Jin;Whang, Jun-Gu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.768-773
    • /
    • 2016
  • Engine valve seat and face, which are the important factors affecting engine performance, are required to have wear, heat and corrosion resistance. In order to produce surface layer with these characteristics, PTA(plasma transferred arc) surfacing procedure is generally employed, but problems, such as large HAZ and high dilution etc., frequently occurr. Laser cladding, which overcomes the drawbacks of conventional technologies, can be employed to create a superior clad layer with low dilution, small heat affected zone, and minimal distortion. However, in case cladding is to be applied to a large area, it is necessary to overlap 1 pass clad layer because of limited clad layer width. Two criteria for the overlapping ratio-beam size and clad layer width-have been considered thus far. Upon inspection of multi pass clads, produced by different overlapping criteria, it was observed that the greater the increase in overlapping ratio, the greater was the decrease in clad layer width and increase in clad layer height regardless of the criterion used. However, a multi pass clad overlapped by the beam size criterion demonstrated a higher hardness value than a clad overlapped by the clad layer width owing to decreasing dilution of the substrate. In conclusion, the beam size was defined as the criterion for the overlapping, because the clad layer width increased or decreased depending upon process parameters.