• 제목/요약/키워드: Dilution Zone

검색결과 92건 처리시간 0.022초

비성층 해양방류수역에서의 하수플륨의 혼합구역 특성분석 (Mixing Zone Analysis of Outfall Plumes in Unstratified Oceanic Environment)

  • 강시환;박광순;오병철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.455-458
    • /
    • 2002
  • Mixing zone characteristics of the wastewater effluents discharged from an ocean outfall have been investigated using an outfall mixing zone analysis method. This analysis was applied to Sokcho ocean outfall case and was used to simulate the concentration distribution of wastewater effluents. Hourly concentration distributions of outfall effluent discharges were averaged for the period of 15 days. The results show that near-field dilution was relatively high with the dilution of 130 for the winter season.

  • PDF

예혼합 희박연소 가스터빈 연소기의 저 NOx 특성 (The Low-NOx Characteristics of Premixed Lean-Burn Gas Turbine Combustor)

  • 배형수;안국영;박종일;안진혁;김용모
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.201-207
    • /
    • 1999
  • The combustion characteristics for the low NOx 50 kW-class gas turbine combustor have been experimentally investigated. In order to achieve the premixing and the lean burn combustion, the geometries of the primary zone including premixed chamber were modified from conventional combustor. The centerline profiles of CO and NO concentration, and temperature were measured for the premixed combustors with or without dilution holes in the liner. The effects of the pilot fuel injection rate and air dilution on flame stabilization and pollutant (CO, NO) emission are discussed in detail.

  • PDF

가스터빈 연소기 기본형상 결정에 관한 연구 (A Study on the Preliminary Design of Gas Turbine Combustor)

  • 안국영;김한석;김관태;배진호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.135-151
    • /
    • 1997
  • The preliminary design and performance test for determining dimensions of gas turbine combustor were investigated. The combustor design program was developed and applied to design our combustor. and detailed design for determining of swirler. dome and liner holes were performed experimentally. The swirler. which govern the combustion characteristics of combustor, was determined $40^{\circ}$ as swirl angle at first performance test. After second performance test the swirler was re-determined by 24 mm i.d.. 34 mm o.d., and swirl angle of $45^{\circ}$. The geometry of liner holes were determined by considering the flame stability and recirculation zone size. It was found that flame can be more easily stabilized by adjusting the swirier dimensions rather than liner holes. The geometry of swirler and liner holes were re-determined by final performance test with dilution holes. Also. the performance of combustor was evaluated by analysis of exhaust gases.

  • PDF

수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석 (Mixing Zone Analysis on Outfall Plume considering Influent Temperature Variation)

  • 김지연;이중우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.247-253
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on "how to dispose the treated municipal water and wastewater in harbor" brings peoples′ concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water and tidal changes, CORMIX(Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.

  • PDF

엔진밸브 시트 표면의 오버레이층 특성에 미치는 용접법의 영향 (Effect of the Welding Methods on the Characteristics of Overlaying Seat-surfaces of Engine Valves)

  • 이병영;최병길
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.517-524
    • /
    • 2002
  • An overlaying of the seating surfaces of engine valves by OAW, GTAW or PTA weldings are common practice. The OAW method of a lower torch energy density compared to GTAW and PTA methods produces smoother deposits but the pain size at the vicinity of the interface is increased remarkably up to $30~50{\mu\textrm{m}}$ (that of base metal is about $10\mu\textrm{m}$). It's grain coarsening and the solute dilution are related to the decarburizing during OAW could be minimized by reducing the preheating temperature and by maintaining the carbide precipitates in base metal prior to welding. The formation of columnar structures and carbide precipitation zone in the vicinity of the GTAW welded interface, because of the high heat concentration, causes weakened zone on the valve seat face. The width of the reaction boundary zone is about $50\mu\textrm{m}$ for PTA and GTAW overlaying, and about $150\mu\textrm{m}$ for OAW welding. The smaller width of the reaction boundary zone is the less the solute-dilution rate. Thereby PTA welding may be recommended for overlaying of the seating surfaces.

Effect of Water Adulteration on the Rheology and Antibacterial Activities of Honey

  • ANIDIOBU, Vincent Okechukwu
    • 식품보건융합연구
    • /
    • 제8권5호
    • /
    • pp.11-20
    • /
    • 2022
  • Honey was diluted with different percentages of water and was analysed rheologically at room temperature of 27℃. The rheological profiles of pure and impure honey samples were measured at low shear rates (0.01-4.16s-1). This work developed a structural kinetic model, which correlated well with the rheological data. The new model was used to categorise honey samples using their average molecular weights as one of the distinctive properties. Also, the kinetics order in the new model predicts the number of active components in the "honey" undergoing deformation. Honey produced third order kinetics to depict the monomers, oligomers and water content in honey. Pure honey exhibits peculiar non-Newtonian rheological behaviour. The behaviour of water is Newtonian. Dilution of honey with different percentages of water turns the resulting fluid Newtonian from 10% dilution with water. This study analysed the antibacterial activities of honey and serially adulterated samples against Staphylococcus aureus and Pseudomonas aeruginosa. The antibacterial analyses of honey were conducted using Kirby Bauer's well diffusion method. The results indicated that pure honey exhibited a zone of inhibition against both organisms. Also, the diameter of the zone of inhibition decreased with increasing dilution of honey, suggesting a correlation with the rheological method.

속초 해양방류 하.폐수의 혼합구역에 대한 특성분석 (Mixing Zone Analysis of Wastewater Effluent Discharged from Sokcho Ocean Outfall)

  • 강시환;박연숙;김상익;이호진
    • 한국해안해양공학회지
    • /
    • 제13권3호
    • /
    • pp.245-253
    • /
    • 2001
  • 속초 하수종말처리장에서의 하·폐수 해양방류에 따른 혼합구역 특성을 파악하기 위해 Huang et al.(1996)의 분석방법을 활용하여 혼합구역 모형을 수립하였다. 겨울철인 11월 하순부터 1월까지 약 2개월 동안 속초 해양방류수역에서 매시간 연속 관측된 해류, 해수 밀도의 성층자료, 그리고 하수 방류량자료를 입력한 모형모의를 통해 속초 해양방류수역에서 하수농도의 분포변화를 계산하였으며, 동일 기간에 관측된 조석자료를 토대로 약 15일 간격으로 구분한 기간 동안에 대해 평균한 농도분포를 제시하였다. 이 결과에 의하면 겨울철동안 평균된 최소희석률은 130으로 방류 하수의 혼합·의석이 대체로 양호했다. 그러나 해안에 평행한 연안류와 조류의 주 방향에 따라 방류하수의 혼합구역이 외해보다는 해변 쪽으로 확장되고 있어 인근 해수욕장의 수질악화에 큰 영향을 미칠 것으로 판단된다.

  • PDF

인버스 확산화염에서의 나노 수트 입자 생성 (Nano-Soot Particle Formation in Inverse Diffusion Flames)

  • 이의주;신현준;오광철;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.19-26
    • /
    • 2003
  • Experimental measurements of flame structure and soot characteristics were performed for ethene inverse diffusion flames (IDF). IDF has been considered as the excellent flow field to study the incipient soot because soot particle do not experience the oxidation process. In this study, LIF image clarified the reaction zone of IDF with OH signal and PAH distribution. laser light scattering technique also identified the being of soot particle. To address the degree of soot maturing, C/H ratio and morphology of soot sample were investigated. From these measurements, the effect of flow residence time and temperature on soot inception could be suggested, and more details on soot characteristic in the IDF was determined according to fuel dilution and flame condition. The fuel dilution results in a decrease of temperature and enhancement of residence time, but the critical dilution mole fraction is existed for temperature not to effect on soot growth. Also, the soot inception evolved on the specific temperature and its morphology are independent of the fuel dilution ratio of fuel.

  • PDF

실내 오염물질의 희석환기에관한 모델링 (Modelling for Dilution Ventilation of Indoor Contamination Materials)

  • 심성훈;조상준;김광영
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.31-42
    • /
    • 1989
  • To investigate design factors of dilution ventilation system, numerical analysis of air contamination flow and concentration distribution have been made, by using the low Reynolds number turbulent model. And flow visualization and measurement of particle concentration for that model also have been made. By comparing of these results we have secured the essential data for the adequate counterplan of dilution ventilation system. The results of this study are as follows: 1) Inlet should be located near the wall for the prevention of the formation of the recircula¬tion zone. 2) In case of natural exhaust, air contamination flow is driven to the far outlet from the inlet. 3) It is favorable for dilution to make turbuence as much as possible.

  • PDF

도시 하수의 해양방류 및 근역혼합특성 분석 (Analyses of Ocean Discharges Municipal Water and its Near-Field Mixing Characteristics)

  • 김강만;김지연;이중우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1999년도 추계학술대회논문집
    • /
    • pp.243-252
    • /
    • 1999
  • Recently several research groups using CORMIX, approved by EPA, have been working on the hydrodynamic mixing processes due to the ocean discharges. It provides a useful tool for analyzing near field mixing characteristics through the outfall system. This paper applies CORMIX 1 & 2 to the Pusan Jungang Effluent Outfall System, which is planned to be in the Gamchun harbour and will be completed in 2011. This model output shows the trajectoral variation of dilution and concentration for three cases of outfall system. Dilution differences have been simulated and found the highest dilution condition under the different displacement of outfall system. On the basis of these outputs it will be proposed the optimum outfall system type and location. This approach might contribute on protecting the serious water quality problem due to the ocean discharge.