• 제목/요약/키워드: Digital subtraction method

검색결과 65건 처리시간 0.032초

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권2호
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

2급 치근이개부 치료 시 흡수성 차폐막, 동종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석 (An Assessment on effect of Bioabsorbable membrane, allogenic bone and Platelet Rich Plasma in Class II furcation involvement by digital subtraction radiography)

  • 김상훈;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.173-186
    • /
    • 2002
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)) in humans by digital subtraction radiography. 12 teeth(control group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)), and 12 teeth(test group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)), bioabsorable membrane(BioMesh(R)) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program (5% significance level). The results were as follows: 1. In test group, the radiopacity in 3 months after surgery were significantly increased than 1 month after surgery(p<0.05). However. there were no significant difference between 1 month after surgery and 3 months after surgery in control group(p>0.05). 2. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 1 month after surgery(p<0.05) 3. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

2급 치근 이개부 치료 시 합성골 이식 및 혈소판 농축 혈장의 골재생 효과에 대한 디지털 공제술의 정량적 분석 (The Quantitative Analysis by Digital Subtraction Radiography on the Effect of Platelet Rich Plasma Combined with Synthetic Bone Graft on Grade II Furcation Involvement)

  • 오지수;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제31권2호
    • /
    • pp.465-475
    • /
    • 2001
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with and without porous resorbable calcium carbonate($Biocoral^{(R)}$)in humans by digital subtraction radiography. 15 teeth(control group) were treated with porous resorbable calcium carbonate($Biocoral^{\(R)}$), and 15 teeth(test group) were treated with porous resorbable calcium carbonate($Biocoral^{(R)}$) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program(5% significance level). The results were as follows: 1. In test group, the radiolucency in 3 months after surgry were significantly increased than 1 month after surgery(p<0.05). 2. In test group, there were no significant difference between 1 month after surgery and 6 months after surgery(p>0.05). 3. In test group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. In control group, the radiolucency in 3 months and 6 months after surgery were significantly increased than 1 month after surgery(p<0.05). 5. In control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 6. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

  • PDF

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • 제24권5호
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

골 내 결손 치료 시 법랑 기질 단백질과 이종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석 (The quantitative analysis by digital subtraction radiography on the effect of Enamel Matrix Protein and Platelet-Rich Plasma, combined with Xenograft in the treatment of intrabony defect in humans)

  • 한금아;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.961-974
    • /
    • 2005
  • Various biological approaches to the promotion of periodontal regeneration have been used. These can be divided into the use of growth and differentiation factors, application of extracellular matrix proteins and attachment factors and use of mediators of bone metabolism. The purpose of this study was to evaluate the effect of enamel matrix protein and platelet-rich plasma on the treatment of intrabony defect, with bovine-derived bone powder in humans by digital subtraction radiography. 12 teeth(experimental I group) were treated with enamel matrix protein combined with bovine-derived bone powder and 12 teeth(experimental II group) were treated with platelet-rich plasma combined with bovine-derived bone powder. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content was assessed in the method that two radiography were put into computer program to be overlapped and the previous image was subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program for windows(5% significance level). The results were as follows: 1. The radiolucency in 3 months after surgery was significantly increased than 1 month after surgery in both groups(experimental I and II groups)(p<0.05). 2. The radiopacity in 6 months after surgery was significantly increased than 3 months after surgery in both groups(experimental I and II groups) (p<0.05). 3. In experimental I group, there was no significant difference between 1 month and 6 months after surgery. 4. In experimental II group. the radiopacity in 6 months after surgery was significantly increased than 1 month after surgery(p<0.05). 5. There was no significant difference between experimental I and II group at 1 month and 3 months after surgery, but the radiopacity in experimental II group was significantly increased at 6 months after surgery(p<0.05). In conclusion, platelet-rich plasma can enhance bone density than enamel matrix protein until 6 months after surgery.

해체와 구성을 이용한 다중 스케일 균열 검출 (Multi-scale crack detection using decomposition and composition)

  • 김영로;정지영
    • 디지털산업정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.13-20
    • /
    • 2013
  • In this paper, we propose a multi-scale crack detection method. This method uses decomposition, composition, and shape properties. It is based on morphology algorithm, crack features. We use a morphology operator which extracts patterns of crack. It segments cracks and background using opening and closing operations. Morphology based segmentation is better than existing integration methods using subtraction in detecting a crack it has small width. However, morphology methods using only one structure element could detect only fixed width crack. Thus, we use decomposition and composition methods. We use a decimation method for decomposition. After decomposition and morphology operation, we get edge images given by binary values. Our method calculates values of properties such as the number of pixels and the maximum length of the segmented region. We decide whether the segmented region belongs to cracks according to those data. Experimental results show that our proposed multi-scale crack detection method has better results than those of existing detection methods.

Detection and Recognition of Illegally Parked Vehicles Based on an Adaptive Gaussian Mixture Model and a Seed Fill Algorithm

  • Sarker, Md. Mostafa Kamal;Weihua, Cai;Song, Moon Kyou
    • Journal of information and communication convergence engineering
    • /
    • 제13권3호
    • /
    • pp.197-204
    • /
    • 2015
  • In this paper, we present an algorithm for the detection of illegally parked vehicles based on a combination of some image processing algorithms. A digital camera is fixed in the illegal parking region to capture the video frames. An adaptive Gaussian mixture model (GMM) is used for background subtraction in a complex environment to identify the regions of moving objects in our test video. Stationary objects are detected by using the pixel-level features in time sequences. A stationary vehicle is detected by using the local features of the object, and thus, information about illegally parked vehicles is successfully obtained. An automatic alarm system can be utilized according to the different regulations of different illegal parking regions. The results of this study obtained using a test video sequence of a real-time traffic scene show that the proposed method is effective.

The Effect of the Speech Enhancement Algorithm for Sensorineural Hearing Impaired Listeners

  • Kim, Dong-Wook;Lee, Young-Woo;Lee, Jong-Shill;Chee, Young-Joon;Lee, Sang-Min;Kim, In-Young;Kim, Sun-I.
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.732-743
    • /
    • 2007
  • Background noise is one of the major complaints of not only hearing impaired persons but also normal listeners. This paper describes the results of two experiments in which speech recognition performance was determined for listeners with normal hearing and sensorineural hearing loss in noise environment. First, we compared speech enhancement algorithms by evaluation speech recognition ability in various speech-to-noise ratios and types of noise. Next, speech enhancement algorithms by reducing background noise were presented and evaluated to improve speech intelligibility for sensorineural hearing impairment listeners. We tested three noise reduction methods using single-microphone, such as spectrum subtraction and companding, Wiener filter method, and maximum likelihood envelop estimation. Their responses in background noise were investigated and compared with those by the speech enhancement algorithm that presented in this paper. The methods improved speech recognition test score for the sensorineural hearing impaired listeners, but not for normal listeners. The results suggest the speech enhancement algorithm with the loudness compression can improve speech intelligibility for listeners with sensorineural hearing loss.

자기광학현미경으로부터 관찰한 자구모양의 픽셀값 연산을 이용한 자벽선 결정방법 (Decision Method of Magnetic Domain Walls Using Pixel Value Operation in the Magnetic Domain Image Observed by Kerr Microscopy)

  • 김영학
    • 한국자기학회지
    • /
    • 제27권1호
    • /
    • pp.35-40
    • /
    • 2017
  • 기존의 광학현미경을 분해 하여 Kerr 현미경을 구성한 다음, 180도 자벽을 가지는 극박 3 %Si-Fe에 대해 자구모양을 관찰하였다. CCD 카메라로 취득한 한 단 한 장의 디지털 자구모양으로부터 자구영역의 경계선을 고가의 고속 영상처리장치 없이 결정하였다. 자구모양의 경계선 결정 방법은 디지털 자구모양의 픽셀값을 감산, 적분, 최소자승법의 연산을 이용하는 것이다. 이 방법은 많은 디지털 이미지를 연속적으로 취득하여 다중 합산하는 종래의 방식보다는 비용이 적게 든다. 이 연구 결과로부터 3개의 경계선과 0.085[T]의 자속밀도가 구해져 시편의 중심부와 같이 $180^{\circ}$ 자벽 만이 형성되는 영역이라면 이 방법을 적용할 수 있다.

디지탈 혈관 조영장치를 이용한 실시간 영상처리와 심장파라미터의 측정 (Real time image processing and measurement of heart parameter using digital subtraction angiography)

  • 신동익;구본호;박광석;민병구;한만청
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.570-574
    • /
    • 1990
  • Detection of left ventricular boundary for the functional analysis of LV(left ventricle)is obtained using automatic boundary detection algorithm based on dynamic programming method. This scheme reduces the edge searching time and ensures connective edge detection, since it does not require general edge operator, edge thresholding and linking process of other edge. detection methods. The left ventricular diastolic volume and systolic volume and systolic volume were computed after this automatic boundary detection, and these Volume data wm applied to analyze LV ejection fraction.

  • PDF