• Title/Summary/Keyword: Digital subtraction image method

Search Result 39, Processing Time 0.025 seconds

Real-time 3D model generation system using multi-view images (다시점 영상을 이용한 실시간 3D 모델 생성 시스템)

  • Park, Jeong-Sun;Son, Hyung-Jae;Park, Jeung-Chul;Oh, Il-Seok
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.383-392
    • /
    • 2017
  • This paper introduces a real-time 3D model generation system that can process in real time from multi-view image acquisition to image-based 3D model generation. This system describes how to collect, transmit, and manage the HD images input from 18 cameras and explain the background separation and smooth 3D volume model generation process. This paper proposes a new distributed data transmission and reception method for real-time processing of HD images input from 18 cameras. In addition, we describe a codebook-based background separating algorithm and a modified marching cube algorithm using perspective difference interpolation to generate smooth 3D models from multi-view images. The system is currently being built with a throughput rate of 30 frames per second.

Endovascular Treatment of a Ruptured Posterior Inferior Cerebellar Artery Aneurysm during Pregnancy

  • Kim, Ki Dae;Chang, Chul Hoon;Choi, Byung Yon;Jung, Young Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.273-276
    • /
    • 2014
  • Aneurysmal subarachnoid hemorrhage (SAH) during pregnancy is quite rare, however it has a high maternal mortality rate. A pregnant woman in the 16th gestational week was admitted to our hospital with a drowsy level of consciousness. A brain magnetic resonance (MR) image showed hemorrhage on the prepontine cistern, and both sylvian fissures, and MR angiography and cerebral digital subtraction angiography demonstrated an aneurysm at the left posterior inferior cerebellar artery (PICA). We performed endovascular coil embolization attempting to minimize radiation exposure. She was discharged with no neurologic deficit and delivered a healthy baby by cesarean section at the 38th week of gestation. This case study reported the shortest gestational period and this is the first report on an aneurysmal rupture arising from PICA which was treated using an endovascular method. Using an appropriate technique for reduced radiation exposure to the fetus and limited alterations in maternal-fetal physiology, endovascular coil embolization could guarantee good results in treatment of aneurysmal SAH in pregnant women.

Evaluation of peri-implant bone density changes in $Br{\aa}nemark$ implants by computer assisted densitometric image analysis (CADIA) (디지털 공제술을 이용한 $Br{\aa}nemark$ 임플란트 주위 골조직 분석)

  • So, Sung-Soo;Noh, Hyuen-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Chae, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.137-150
    • /
    • 2007
  • CADIA(Computer-assisted densitometric image analysis) method is used to analyze bone density changes around the implants. The usefullness and reproducibility of the method was assessed. We tried to find out if there is any possibility to quantitiate and qualitify peri-implant bone density change as time passes. And we concluded that this newly developed linear analysis is efficient for analyzing peri-implant bone density change non-Invasively. In this study, 2152 machined $Br{\aa}nemark$ fixtures installed from 1994 to 2002 in the department of Periodontics, Dental hospital of College of Dentistry, Yonsei University were included. Of these fixtures 22 radiographically analyzable failed fixtures were used as experimental group, and 22 successful implants placed in the same patient were used as control group. 1. 57 out of 1635 machined $Br{\aa}nemark$ standard and Mk II implants system failed, the survival rate was 96.5%. And 11 out of 517 machined $Br{\aa}nemark$ Mk III and Mk IV implants system failed, the survival rate was 97.9%. Total survival rate was 96.8%. 2. 22 failed implants were used for the analysis, 10 of which failed before prosthetic treatment due to infection and overheating. 12 failed due to overload after prosthetic treatment, 63.6% of which failed during the early phase of functional loading, i, e. before 1 year of loading. 3. Bone density change values around coronal region of the failed implants were $-6.54{\pm}6.35$, middle region were $-3.53{\pm}5.78$, apical region were $-0.75{\pm}10.33$, resulting in average of $-3.71{\pm}8.03$. 4. Bone density change values around coronal region of the successful implants were $4.25{\pm}4.66$, middle region were $6.33{\pm}5.02$, apical region were $9.89{\pm}4.67$, resulting in average of $6.27{\pm}5.29$. 5. There was a statistically significant difference between two groups (p<0.01). In conclusion, the linear analysis method using computer-assisted densitometric image analysis could be a useful method for the analysis of implants, and could be used for future implant researchs.

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA (4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성)

  • Bae, Sung-Jin;Lim, Cheong-Hwan;Park, Byung-Rae;Shin, Woon-Jae;Kim, Jung-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

ANALYSIS ON THE PREDICTOR OF DISEASE PROGRESSION IN REFRACTORY PERIODONTITIS (난치성 치주염의 질환진행 예견 인자에 관한 분석)

  • Lee, Hae-Joon;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.109-126
    • /
    • 1993
  • Refractory periodontitis manifest progressive attachment loss in a rapid and unrelenting manner regardless of the type or frequency of therapy applied. The purpose of this study was ta evaluate the relation between the level of cytokines in GCF and periodontopathic microflora with disease activity of refractory periodontitis. Selection of patients with refractory periodontitis (7 males, 3 females) were made by long term clinical observation including conventional clinical history and parameters. Teeth that showed pocket depth greater than 6mm were selected as sample teeth. Subjects were examined at baseline and after 3 months. Prior to baseline test, individual acrylic stent was fabricated. Reference grooves were made on each sample tooth site. Pocket depth and attachment loss were measured by Florida Probe. Gingival index was measured at 4 sites each sample teeth. Disease activity was defined as attachment loss of ${\ge}$ 2.1mm, as determined by sequential probing and tolerance method. The pattern and amount of alveolar bone resorption was observed with quantitative digital subtraction image processing radiography. Morphological analysis of subgingival bacteria was taken by phase contrast microscopy. Predominant cultivable bacterial distribution and frequency were compared between disease-active and disease-inactive site using immunofluorescence microscopy and selective microbial culturing. Levels of $interleukin-l{\beta}$, 2, 4, 6 and $TNF-{\alpha}$ in GCF and blood serum sample were quantified by ELISA. In active sites, P. intermedia was significantly increased to compare with inactive site. $IL-1{\beta}$, IL-2, IL-6 and $TNF-{\alpha}$ in GCF were increased in active sites and IL-2 in serum was increased in active patients significantly. Alveolar bone loss in active site was correlated with $IL-1{\beta}$, IL-2 in GCF. And loss of attachment in active site was correlated with IL-2 in GCF. These results demonstrate that IL-2 in serum, $IL-1{\beta}$, IL-2, IL-6 and $TNF-{\alpha}$ in GCF, P, intermedia might be used as possible predictors of disease activity in refractory periodontitis before it is clinically expressed as attachment loss and quantitative alveolar bone change.

  • PDF

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.