• Title/Summary/Keyword: Digital radiograph

Search Result 65, Processing Time 0.02 seconds

Development of a Verification Tool in Radiation Treatment Setup (방사선치료 시 환자자세 확인을 위한 영상 분석 도구의 개발)

  • 조병철;강세권;한승희;박희철;박석원;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • In 3-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), many studies on reducing setup error have been conducted in order to focus the irradiation on the tumors while sparing normal tissues as much as possible. As one of these efforts, we developed an image enhancement and registration tool for simulators and portal images that analyze setup errors in a quantitative manner. For setup verification, we used simulator (films and EC-L films (Kodak, USA) as portal images. In addition, digital-captured images during simulation, and digitally-reconstructed radiographs (DRR) can be used as reference images in the software, which is coded using IDL5.4 (Research Systems Inc., USA). To improve the poor contrast of portal images, histogram-equalization, and adaptive histogram equalization, CLAHE (contrast limited adaptive histogram equalization) was implemented in the software. For image registration between simulator and portal images, contours drawn on the simulator image were transferred into the portal image, and then aligned onto the same anatomical structures on the portal image. In conclusion, applying CLAHE considerably improved the contrast of portal images and also enabled the analysis of setup errors in a quantitative manner.

  • PDF

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

EFFECT OF DECALCIFIED FREEZE-DRIED ALLOGENEIC BONE GRAFT(DFDB) ON THE JAW DEFECTS AFTER CYST ENUCLEATION (낭종 적출후 악골 결손부 치유에 관한 동종골 이식 효과에 관한 연구)

  • Lee, Dong-Keun;Min, Seung-Ki;Kwon, Kyung-Hwan;Sung, Hun-Mo;Park, Hwa-Kyu;Kang, Mun-Jeong;Sin, Ki-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.360-365
    • /
    • 1999
  • This study was aimed to suggest to better treatment method of jaw cyst that the maximum diameter was wider than 3cm, using different treatment and clinical and radiographic result. We divided the 60 patients into three groups, group A(20 patients) were treated with cyst enucleation and Decalcified Freeze-Dried Allogeneic Bone(DFDB) graft, group B(20 patients) were treated with cyst enucleation and autogenous bone graft, group C(20 patients) were treated with only cyst enucleation. Each group was evaluated with panoramic radiograph and clinical sign & symptom at pre-op and post-op(immediate, 6, 12, 24, 36 month). Bone density was evaluated with disital densitometer. The result was as follows : 1. Post-Op infection was higher in group C(4 pts.) than in group A(1 pt.) and B(1 pt.) 2. Post-Op gingival recession was higher in group C(3 Pts.) than in group A(1 pt.) and B(1 pt.) 3. Anatomic distortion was higher in group C(3 Pt.) than in group A(1 Pt.), and B(1 pt.) 4. Reoperation was done in two patients who were in group C 5. There were donor site morbidity in two patients 6. There was no significant difference between group A and B in their bony density in their follow up period(p>0.05). 7. There were significant differences between group A, B and group C in their bony density until post-op 24 months but a little differences at post-op 36 months(P<0.01)

  • PDF