• Title/Summary/Keyword: Digital pressure control

Search Result 136, Processing Time 0.026 seconds

Pelvic Floor Muscle Exercise by Biofeedback and Electrical Stimulation to Reinforce the Pelvic Floor Muscle after Normal Delivery

  • Lee, In-Sook;Choi, Euy-Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.8
    • /
    • pp.1374-1380
    • /
    • 2006
  • Purpose. This study was conducted to investigate the effectiveness of pelvic floor muscle exercise using biofeedback and electrical stimulation after normal delivery. Methods. The subjects of this study were 49 (experimental group: 25, control group: 24) postpartum women who passed 6 weeks after normal delivery without complication of pregnancy, delivery and postpartum. The experimental group was applied to the pelvic muscle enforcement program by biofeedback and electrical stimulation for 30 minutes per session, twice a week for 6 weeks, after then self-exercise of pelvic floor muscle was done 50-60 repetition per session, 3 times a day for 6 weeks. Maximum pressure of pelvic floor muscle contraction (MPPFMC), average pressure of pelvic floor muscle contraction (APPFMC), duration time of pelvic floor muscle contraction (DTPFMC) and the subjective lower urinary symptoms were measured by digital perineometer and Bristol Female Urinary Symptom Questionnaire and compared between two groups prior to trial, at the end of treatment and 6 weeks after treatment. Results. The results of this study indicated that MPPFMC, APPFMC, DTPFMC were significantly increased and subjective lower urinary symptoms were significantly decreased after treatment in the experimental group than in the control group. Conclusions. This study suggested that the pelvic floor muscle exercise using biofeedback and electrical stimulation might be a safer and more effective program for reinforcing pelvic floor muscle after normal delivery.

Implementation of a Mixing-Ratio Control System for Two-Component Liquid Silicone Mixture (이액형 액상실리콘 재료의 혼합비율 제어 시스템 개발)

  • Choo, Seong-Min;Kim, Young-Min;Lee, Keum-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.688-694
    • /
    • 2018
  • The mixture ratio of two-component liquid silicone is important for the inherent physical characteristics of the finished product. Therefore, it is necessary to uniformly control the ratio of the main material and the sub-material. In this paper, a mixing-ratio control system was designed, which consists of a digital flow meter and a flow control system to measure the flow rate of the raw materials and a pumping system to maintain constant pressure and transfer of the raw materials. In addition, a program was developed to control the organic interlocking and mixing ratio. For the verification of the developed system, we compared the actual weight of raw material with the value measured by the flow meter during pumping, and we measured the physical properties of the mixed material by making test samples with and without the application of the mixing-ratio improvement algorithm. The measured value was close to the reference value with a hardness range of 46-47 and tensile strength of 9.3-9.5 MPa. These results show that the mixing ratio of the liquid silicone is controlled within an error range of ${\pm}0.5%$.

A Digital Control of Squeeze Film Damper (스퀴즈 필름 댐퍼의 디지탈 제어)

  • 송용한;최현석;최세헌;임윤철
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.24-31
    • /
    • 1998
  • A new type squeeze film damper is proposed and its dynamic characteristics are investigated experimentally. The new one has a pulsating flow supply system which properly adds high pressure oil to the oil film of the damper so that the rotor vibration can be controlled actively. As the result, the amplitude of the rotor vibration can be reduced considerably. The algorithm which compensates the phase lag of servo valve as well as the high-performance servo valve are required in order that a new type squeeze film damper can be more effective device to attenuate the rotor vibration than typical one.

Nonlinear analysis of a pneumatic actuation system by digital simulation (전산모사에 의한 공압구동장치의 비선형 해석)

  • 조택동;신효필;문의준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1104-1109
    • /
    • 1991
  • Recently, Pneumatic Actuation System (PAS) has been used increasingly as a high performance fin-control servo actuation systems because of the special advantages of pneumatic units: primarily their low cost, small size, light weight, and tolerance to broad temperature extremes. In this study, a nonlinear model of PAS is derived through the detailed analysis of the major components in the typical system. The model includes nonlinear flow-pressure relationships of the flow through the solenoid valve openings and orifices, PWM algorithm for driving two solenoid valves as a closed-center 3-way valve for minimum gas consumption, solenoid valve dynamics, saturation, and friction. Simulation results are compared with the experimental ones for square and sinusoidal inputs to see the validity of the model. Independent of the shape and magnitude of the input signals, both results are in good agreements with minor difference.

  • PDF

[ $H_{\infty}$ ] Optimal Control for Single-Rod Hydraulic Servo-System with DSP (DSP를 이용한 편로드 유압서보시스템의 $H_{\infty}$ 최적제어)

  • Jung, Gyu-Hong
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.515-520
    • /
    • 2001
  • Due to the high power to weight ratio and fast response under heavy load, the hydraulic systems are still applied to the development of many industrial facilities such as heavy duty construction vehicles, aerospace/military weapon actuating systems and motion simulators. Unlike the other actuators, single-rod hydraulic cylinder exhibits a lot different dynamic characteristics between the extending and retracting stroke because of the difference in pressure acting areas. In this research, in order to overcome this nonlinear feature, $H_{\infty}$ optimal controller was designed and implemented with DSP board that was specifically developed for the experiment. From the experimental result, we could confirm that the overall performance of single-rod hydraulic servo system is similar with the results as we expected in the design stage.

  • PDF

Modified FxLMS Algorithm for Active Noise Control and Its Real-Time Implementation

  • Mu, Xiangbin;Ko, JinSeok;Rheem, JaeYeol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.172-176
    • /
    • 2013
  • This paper presents a modified filtered-x least mean square (FxLMS) algorithm to improve the stability of active noise control (ANC) system in realistic environment. A real-time ANC system employing modified FxLMS is designed and implemented on digital signal processor (DSP) board. The ANC system is evaluated for cancelling various tonal frequency noises in the range from 100 to 500 Hz and the performance is measured in terms of sound pressure level (SPL) attenuation. Experiment results show that a quiet zone with maximum 20 dB SPL attenuation can be generated around the location of error microphone.

Reliability Analysis of Access Door Opening Force Measured with a Digital Force Gauge of a Pressurized Smoke Control Zone and Presentation of Optimum Conditions for the Opening Force (디지털 측정기로 측정된 급기가압 제연구역의 출입문 개방력에 대한 신뢰성 분석 및 최적 조건 제시)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.468-473
    • /
    • 2016
  • The aim of this study was to measure the opening force of an access door of a pressurized smoke control zone and verify the reliability of the opening force. For the access door opening force, the opening load of the access door was measured before and after pressurized air had entered the smoke control zone. The reliability of the measured values was verified using the Anderson Darling's statistical analysis method of the Minitab Program. Because the analyzed P values were greater than 0.05 except for some floors before and after the operation of the smoke control equipment, the opening force was found to have 95% reliability. The normal distribution of the measured values showed no relationship with the operation of the smoke control equipment and the precision of the force gauge was believed to be reliable. The major factors for the optimal design of the pressurized smoke control equipment include the precision and reliability of the force gauge, the correct posture of the measuring person, and the same conditions for access doors. Therefore, a digital force gauge is believed to be suitable for measuring the opening force of the access door of a pressurized smoke control zone. In addition, standardization of the posture of a measuring person, the setup of the initial opening force of an access door, etc., are major variables for effective measurements of the door opening force of an access door.

A Design and Implementation Digital Vessel Bio Emotion Recognition LED Control System (디지털 선박 생체 감성 인식 LED 조명 제어 시스템 설계 및 구현)

  • Song, Byoung-Ho;Oh, Il-Whan;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.2
    • /
    • pp.102-108
    • /
    • 2011
  • The existing vessels lighting control system has several problems, which are complexity of construction and high cost of establishment and maintenance. In this paper, We designed low cost and high performance lighting control system at digital vessel environment. We proposed a system which recognize the user's emotions after obtaining the biological informations about user's bio information(pulse sensor, blood pressure sensor, blood sugar sensor etc) through wireless sensors controls the LED Lights. This system classified emotions using backpropagation algorithm. We chose 3,000 data sets to train the backpropagation algorithm. As a result, obtained about 88.7% accuracy. And the classified emotions find the most appropriate point in the method of controlling the waves or frequencies to the red, green, blue LED Lamp comparing with the 20-color-emotion models in the HP's 'The meaning of color' and control the brightness or contrast of the LED Lamp. In this method, the system saved about 20% of the electricity consumed.

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.