• 제목/요약/키워드: Digital oscilloscope

검색결과 66건 처리시간 0.021초

AVR과 PC EPP Protocol을 이용한 디지털 오실로스코프 개발 (A Study for Digital Oscilloscope based AVR and PC EPP Protocol)

  • 문일현;이유상;최관순;안창
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2006년도 추계학술발표논문집
    • /
    • pp.129-132
    • /
    • 2006
  • 본 논문에서는 AVR8535 Micro Controller와 PC의 Parallel EPP Protocol을 이용하여 PC환경에서의 디지털 오실로스코프를 개발하였다. 기존의 오실로스코프는 고가이고 휴대하기가 어려워 필요시에 실험을 측정하기에 불편한 점을 해결하기 위해 저가격의 사용하고 휴대하기 편리한 디지털 오실로스코프를 개발하였다. 어플리케이션 프로그램은 MFC를 이용하였으며 파형 측정 기능과 측정된 데이터를 범용의 데이터형식으로 추출하여 여러 측정환경에 응용할 수 있도록 개발하였다.

  • PDF

발전기 회전자 권선의 층간단락 진단시스템 개발 (Development of Shorted-Turn Diagnosis system for Generator Rotor Winding)

  • 이영준;김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.742-747
    • /
    • 1999
  • On-line diagnosis system has been developed and is now applied the detection of shorted turns in the field winding of large generator. This system consists of data aquisition system and display PC. The data aquisition system detects voltage waveforms from flux probe sensor installed in the stator slot. The display PC shows theshorted-turn situation of generator rotor winding. A shorted-turn diagnosis test wasperformed on five gas turbine generators at the Seoinchon combined cycle power plant. The test was conducted using an new diagnosis system and digital oscilloscope which can identify the pole location, the slot number and the number of shorted turns within each slot. It is confirmed that results of two systems are very same in the field tests.

  • PDF

레이저 간섭계와 포켈스 효과를 이용한 불평등 전계 측정 (A Possible Application of the Nonuniform Electric Field Measurement Using Laser Interferometer and Pockels Effect)

  • 강원종;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.240-245
    • /
    • 2002
  • In this paper, a novel optical measuring system for the measurement of nonuniform electric field was proposed. The electric field distorted by the discharges was detected through proposed optical measuring system based on the Pockets effect and Mach-Zehnder interferometer. In order to produce distorted electric field, corona discharge was generated from needle-plane electrode in air and detected by optical measuring system. This optical measuring system is constructed by He-Ne laser, single mode optical fiber, $2{\times}2$ 50/50 beam splitter, $LiNbO_3$ Pockets cell, photo detector and PC. In this system, output signal of Pockels sensor is measured by digital oscilloscope and transferred to the PC for recording and statistical processing. Through this paper, a promising possibilities of proto-type optical measuring system were evinced.

고주파 교류 자기특성의 컴퓨터 계측시스템 제작 (Construction of high frequency B-H Analyzer.)

  • 김기욱;송재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1170-1172
    • /
    • 1996
  • Analog-digital converter boards for use in personal computers have recently being improved markedly, many kinds of high speed(1 MHz - 10 MHz sampling rale) and over 12-bit vertical resolution A/D boards released. It can be applicable to high frequency magnetic measurements. In measurement of magnetic properties of high frequency, digitizing oscilloscope or trasient recorder are being used. but, those price are often expensive, we constructed PC controlled A-C B-H loop tracer that can measure Bs, Br, He, permeability and may be applied about 100 Hz - 20 kHz range. it use IBM PC compatible 1 M Sample/s, 12 bit A/D converter board with SSH(Simultaneous Sample and Hold).

  • PDF

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

SAE J2716 풀 모드 SENT 컨트롤러의 설계 (Design of SAE J2716 SENT Full Modes Controller)

  • 정준호;조재혁;이성수
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.501-511
    • /
    • 2023
  • 본 논문에서는 차량 어플리케이션에서 디지털 센서 데이터를 직렬 전송하는 기술 표준인 SAE J2716 SENT(Single Edge Nibble Transmission) 프로토콜을 소개하고 분석하였다. SENT는 하나의 데이터 프레임으로 고속 센서 데이터와 저속 센서 데이터를 함께 전송할 수 있으며 고속 채널 3개 모드, 저속 채널 3개 모드, 총 6개의 전송 모드를 가지고 있다. 본 논문에서는 SENT 프로토콜의 6개 모드를 모두 지원하는 SENT 컨트롤러를 Verilog HDL로 설계하고 FPGA로 구현하였으며 오실로스코프와 PC로 동작을 검증하였다.

주파수 대역별 후방복사 프로파일 (Spectral Backward Radiation Profile)

  • 김학준;권성덕
    • 비파괴검사학회지
    • /
    • 제25권5호
    • /
    • pp.362-367
    • /
    • 2005
  • 후방복사된 초음파의 입사각 의존성(프로파일)은 입사지역이 다층경계이거나 깊이방향으로 물성변화가 있을 때 주파수 의존적이다. 지금까지 측정된 후방복사 프로파일은 주로 사용된 탐촉자의 중심 주파수의 특성에 의존하여 표면탄성파의 전반적인 주파수 의존 특성을 이해하는 데는 어려움이 많았다. 디지털 오실로스코프의 DFP(digital filter package)를 이용하여 주파수 대역별 후방복사 프로파일이 실시간 획득되었다. #1200 사포로 표면 처리된 상업적 강재 시편에 대한 주파수 대역별 측정으로부터 표면탄성파가 2% 정도의 음의 기울기(loaded case) 속도 분산성이 있음을 알았고 심하게 녹이 쓴 시편에서는 주파수 대역별로 프로파일의 형태에 큰 변화를 보였다. 주파수 대역별 후방복사 프로파일은 분산성을 가진 표면지역에 대한 비파괴적 평가에 매우 유용할 것으로 본다.

원격응급시스템의 방사선 영상장치 구현 (An Implementation of Radiologic Imaging Device of Remote Emergency Medical System)

  • 조동헌
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.60-65
    • /
    • 2007
  • 구급차에 장착하거나 사고 현장에서 사용할 수 있는 방사선 영상장치를 구현하였다. DC 12[V] 입력 전원에서 X-ray 튜브를 통해서 X-ray를 발생하는 장치를 구성한 후 오실로스코프를 활용하여 특성 실험을 하였다. 그리고 발생된 X-ray에 대해 디지털 디텍터를 이용하여 파일 형태로 저장하는 실험을 하였다. X-ray를 발생시킨 후 디지털 디텍터로 검출한 결과, 파일 크기가 1.67[MB]이고, jpg 형태로 이루어진 방사선정보를 저장할 수 있었다. 구현된 방사선 영상장치는 환자가 의사로부터 공간적으로 멀리 떨어져 있어 시간적으로 진단과 치료가 동시에 이루어지기 어려운 상황에 효율적으로 대처할 수 있는 장점이 있다. 따라서 구현된 방사선 영상장치는 긴박한 상황이 발생한 사고 현장이나 이동 중인 구급차 내에서 X-ray 촬영을 함으로써, 환자의 X-선 정보를 응급의료 센터의 의사에게 전달하고 의사의 처방을 받을 수 있는 의료 선진화를 구현하는 데 기여할 수 있을 것으로 기대된다.

의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향 (The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제10권1호
    • /
    • pp.17-22
    • /
    • 1999
  • 임상에서 사용되는 가속기의 설계특성변화가 빔 출력변화에 미치는 영향을 알아봄으로써 보다 효율적인 정도관리를 수행하고자 한다. 선형가속기를 구성하고 있는 여러 가지 요소 중에서 빔 조정 인자들인 이온원부의 입사전류 (INJ-I), 이온원부의 입사전압 (INJ-E), 가속전압 (PFN), 휨자석 전류 (BMI), 펄스반복주파수 (PRF)를 선택하여 디지털 메바트론 제어프로그램 상에서 선형가속기가 자동 제어되는 허용범위를 조사한 후 그 영역내에서 전류값들을 변화시켜가면서 선량에 어떠한 영향을 미치는지 알아보았다. 이온함을 사용하여 홉수선량을 측정하고 오실로스코프를 사용하여 빔 출력의 파형을 분석하였으며 방사선 계측장치로 대칭성과 평평도를 계측하였다. 방사선 가속 장치는 선형가속기 (Mevatron MD, Siemens, Germany)를 이용하였으며, 계측장치로는 RFAplus (Scanditronix, Sweden)를 사용하였다. 그리고 가속기의 설계특성변화 즉 , 빔 조정 인자들의 변화가 선량분포특성에 변화를 주는 것을 측정하기 위해 0.6cc 이온함(Capintec PR06C, USA), 미소전위계(Capintec192, USA)와 오실로스코프 (Tektronix, USA)를 사용하였다. 선형가속기의 선량률과 에너지변화에 영향을 미치는 인자들인 INJ-I, INJ-E, PFN, BMI, PRF의 전압과 전류값들을 변화시켰을 때 인자들마다 차이는 있었지만, 이온함을 사용하여 측정했을 때와 오실로스코프로 출력펄스의 변화를 보았을 때는 선량률의 변화를 확인할 수 있었다. 그러나 RFAplus로 에너지와 대칭성 등에 관한 그래프를 그렸을 때는 거의 동일한 결과를 나타내었다. 인자 INJ-I, INJ-E, PFN, BMI, PRF 들의 D10/D20은 0∼0.02, 대칭성은 0.1-0.2%, 평평도는 0.1∼0.4%의 미세한 변화를 보였다. 디지털화 된 각 인자들의 전류와 전압값들을 변화시킬 때 선량률에는 미세한 영향을 미치게 되지만, 기계자체에서 기준값에 맞추기 위해 자동 제어가 되어 선량분포에는 크게 영향을 미치지는 못하는 것으로 평가되어졌으나 빔 조정 인자들의 특성을 파악함으로써 정도관리의 기초자료를 확보하였다.

  • PDF