• 제목/요약/키워드: Digital microscopic holography

Search Result 4, Processing Time 0.022 seconds

Experimental Study on the Characteristics of Micro Jet Flow Using Digital Microscopic Holography (디지털 현미경 홀로그래피 기법을 이용한 마이크로 액체 제트 유동에 관한 실험적 연구)

  • Lee, Haneol;Lee, Jaiho;Shin, Weon Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.48-53
    • /
    • 2018
  • In this study, the effect of injection pressure on the column diameter and droplet velocity of liquid jet with the weakly turbulent Rayleigh-like breakup mode is experimentally studied using digital microscopic holography (DMH). The injection nozzle has the diameter of $50{\mu}m$ and injection pressure is varied from 0.1 to 0.4 MPa. When the micro liquid jet is injected into still air, the double-pulsed holograms was recorded on a CCD sensor and numerically reconstructed in order to obtain well focused images. In this study, the liquid column diameter from $50{\mu}m$ orifice nozzle is shown to be changed slightly but the droplet velocity is increased proportionally as the injection pressure is increased.

3-Dimensional Measurement using Digital Holographic Microscope and Phase Unwrapping (디지털 홀로그래피 현미경과 위상 펼침을 이용한 3차원 측정)

  • Cho, Hyung-Jin;Kim, Doo-Chul;Yu, Young-Hun;Jung, Won-Gi;Shin, Sang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.329-334
    • /
    • 2006
  • We have reconstructed 3-dimensional images by using the digital holographic microscope and the Mask-cut phase unwrapping algorithm. Off-axis holograms recorded with a magnified image of the microscopic object lens and reference beam are numerically reconstructed in amplitude and phase image by the Fresnel diffraction approximation. We have simultaneously reconstructed 2-dimensional and 3-dimensional images of the sub-micrometer objects.

Damage Measurement for Molybdenum Thin Film Using Reflection-Type Digital Holography (반사형 디지털 홀로그래피를 이용한 Molybdenum 박막의 손상 측정)

  • Kim, Kyeong-Suk;Jung, Hyun-Il;Shin, Ju-Yeop;Ma, Hye-Joon;Kwon, Ik-Hwan;Yang, Seung-Pill;Hong, Chung-Ki;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2015
  • In the fabrication of electronic circuits used in electronic products, molybdenum thin films are deposited on semiconductors to prevent oxidation. During the deposition, the presence of a particle or dust at the interface between the thin film and substrate causes the decrease of adhesion, performance, and life cycle. In this study, a damage measurement targeting two kinds of glass substrate, with and without particles, was performed in order to measure the change in the molybdenum thin film deposition area in the presence of a particle. Clean and dirty molybdenum thin film specimens were fabricated and directly deposited on a substrate using the sputtering method, and a reflection-type digital holographic interferometer was configured for measuring the damage. Reflection-type digital holography has several advantages; e.g., the configuration of the interferometer is simple, the measurement range can be varied depending on the magnification of a microscopic lens, and the measuring time is short. The results confirm that reflection-type digital holography is useful for the measurement of the damage and defects of thin films.

Digital Holographic microscopy based on phase shifting technique (위상천이가법에 의한 디지털 홀로그래피 마이크로스코피에 관한 연구)

  • Park, Kwang-Hee;Chai, Pyung-Seak;Eun, Jae-Jeang
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.3
    • /
    • pp.181-187
    • /
    • 2011
  • In this thesis, digital in-line holographic microscopy has been implemented with enhanced phase shifting technique. It was demonstrated that the zero-order diffraction noise and the twin image can be eliminated by phase-shifting interferometry very effectively. Also the experimental and numerical reconstruction has been incorporated into one set-up operating in real time. Experimental results and the analysis of the phase map indicate that the proposed system can be very useful for the measurement of microscopic objects and 3-D microscopy.