• Title/Summary/Keyword: Digital medicine

Search Result 1,644, Processing Time 0.029 seconds

Venous Congestion in Cerebral Hyperperfusion Syndrome: A Case Report (뇌과관류증후군에서 보일 수 있는 정맥울혈 1례)

  • Bong, Jeong Bin;Kang, Hyun Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.84-87
    • /
    • 2017
  • Cerebral hyperperfusion syndrome (CHS) is a rare complication that can occur when conducting stent insertion or endarterectomy in patients with carotid artery stenosis and is known to be caused by various mechanisms when the blood volume abruptly increases. The main clinical symptoms are unilateral headache, hypertension, seizure, and focal neurologic deficit. Subarachnoid hemorrhage and parenchymal hemorrhage may lead to permanent impairment or death in severe cases. CHS can be predicted by using transcranial Doppler, perfusion magnetic resonance imaging, and single photon emission computed tomography. In our case report, a patient developed CHS subsequent to significant venous congestion caused by carotid artery stent insertion. The patient had preexisting, symptomatic bilateral carotid artery stenosis. Venous congestion occurs when the direction of blood flow changes because of increased blood volume in patients with well-developed collateral vessels. We believe that CHS can be predicted from this finding. This study reports the possibility that CHS could be confirmed by cerebral angiography after insertion of the internal carotid stent.

Effects of electroacupuncture stimulation at Xingjian(LR2) on the facial thermal change by D.I.T.I (행간(行間)(LR2) 전침자극(電鍼刺戟)이 적외선(赤外線) 체열진단상(體熱診斷上) 안면부(顔面部) 온도변화(溫度變化)에 미치는 영향(影響))

  • Kim, Jong-uk;Choi, Sung-yong;Jin, Kyong-son;Hwang, Woo-jun;Min, Sang-jun;Lee, Sun-ho;Lee, Sang-ryong
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.226-239
    • /
    • 2004
  • Objective: Purpose of this study was to examine the effect of electroacupuncture(EA) at Xingjian(LR2) as 'Fire(火)' point of The Leg Absolute Um Liver Meridan(足厥陰肝經 : Chok-Kworum-Kan-Kyong) on the facial thermal change. Methods: Subjects of this study were 15 patients with upperpart(includes head and facial part) fever of human body and two examinations were carried out in each other day. We divided cases of two examinations into two groups. One is experimental group(N=15) that was carried out electroacupuncture stimulation at Xingjian(LR2), the other is control group(N=15) which was carried out electroacupuncture stimulation at optional point(in space between 1st and 2nd fingers) except acupuncture points of 12 meridians. We took the temperature of fixed areas on face by digital infrared thermal image(D.I.T.I.) before and after electroacupuncture stimulation. Those fixed areas on face that was taken temperature are Jingming(BL1), Sibai(ST2), Dicang(ST4), Indang, Shuigou(GV26), Chengjiang(CV24) areas. In cases of temperature of Jingming(BL1), Sibai(ST2), Dicang(ST4) areas, we applied each mean of left and right temperature to statical analysis. Results: In the group of electroacupuncture stimulation at Xingjian(LR2), temperature of every fixed areas on face fell: Jingming(BL1) area's ${\Delta}T=-0.7007{\pm}0.78642$, Sibai(ST2) area's ${\Delta}T=-0.6280{\pm}0.56439$, Dicang(ST4) area's ${\Delta}T=-0.5940{\pm}0.60179$, Indang area's ${\Delta}T=-0.7200{\pm}0.64515$, Shuigou(GV26) area's ${\Delta}T=-0.6160{\pm}0.80487$, Chengjiang(CV24) area's ${\Delta}T=-0.5627{\pm}0.72615$. In Xingjian(LR2) electroacupuncture group, each temperature of Jingming(BL1), Sibai(ST2), Indang areas showed a drop significantly in comparison with control group (p<0.05). But each temperature of Dicang(ST4), Shuigou(GV26), Chengjiang(CV24) areas did not showed a drop significantly in comparison with control group(p>0.05). Conclusions: The results mentioned above showed that electroacupuncture stimulation at Xingjian(LR2) significantly decreased the temperature on face of patients with upperpart fever of human body. In Xingjian(LR2) electroacupuncture group, especially temperature of upper part of face includes eye, cheekbone, forehead regions showed a drop significantly in comparison with control group.

  • PDF

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Physiologic Phonetics for Korean Stop Production (한국어 자음생성의 생리음성학적 특성)

  • Hong, Ki-Hwan;Yang, Yoon-Soo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • The stop consonants in Korean are classified into three types according to the manner of articulation as unaspirated (UA), slightly aspirated (SA) and heavily aspirated (HA) stops. Both the UA and the HA types are always voiceless in any environment. Generally, the voice onset time (VOT) could be measured spectrographically from release of consonant burst to onset of following vowel. The VOT of the UA type is within 20 msec of the burst, and about 40-50 msec in the SA and 50-70 msec in the HA. There have been many efforts to clarify properties that differentiate these manner categories. Umeda, et $al^{1)}$ studied that the fundamental frequency at voice onset after both the UA and HA consonants was higher than that for the SA consonants, and the voice onset times were longest in the HA followed by the SA and UA. Han, et $al^{2)}$ reported in their speech synthesis and perception studies that the SA and UA stops differed primarily in terms of a gradual versus a relatively rapid intensity build-up of the following vowel after the stop release. Lee, et $al^{3)}$ measured both the intraoral and subglottal air pressure that the subglottal pressure was higher for the HA stop than for the other two stops. They also compared the dynamic pattern of the subglottal pressure slope for the three categories and found that the HA stop showed the most rapid increase in subglottal pressure in the time period immediately before the stop release. $Kagaya^{4)}$ reported fiberscopic and acoustic studies of the Korean stops. He mentioned that the UA type may be characterized by a completely adducted state of the vocal folds, stiffened vocal folds and the abrupt decreasing of the stiffness near the voice onset, while the HA type may be characterized by an extensively abducted state of the vocal folds and a heightened subglottal pressure. On the other hand, none of these positive gestures are observed for the SA type. Hong, et $al^{5)}$ studied electromyographic activity of the thyroarytenoid and posterior cricoarytenoid (PCA) muscles during stop production. He reported a marked and early activation of the PCA muscle associated with a steep reactivation of the thyroarytenoid muscle before voice onset in the production of the HA consonants. For the production of the UA consonants, little or no activation of the PCA muscle and earliest and most marked reactivation of the thyroarytenoid muscle were characteristic. For the SA consonants, he reported a more moderate activation of the PCA muscle than for the UA consonant, and the least and the latest reactivation of the thyroarytenoid muscle. Hong, et $al^{6)}$ studied the observation of the vibratory movements of vocal fold edges in terms of laryngeal gestures according to the different types of stop consonants. The movements of vocal fold edges were evaluated using high speed digital images. EGG signals and acoustic waveforms were also evaluated and related to the vibratory movements of vocal fold edges during stop production.

  • PDF

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

Effect on bone formation of the autogenous tooth graft in the treatment of peri-implant vertical bone defects in the minipigs

  • Kim, Seok Kon;Kim, Sae Woong;Kim, Kyung Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.2.1-2.9
    • /
    • 2015
  • Background: The aim of this study was to evaluate the effect of autogenous tooth bone as a graft material for regeneration of bone in vertical bony defects of the minipigs. Material and Methods: Six minipigs were used in this study. Four molars were extracted in the right mandibular dentition and sent to the Korea Tooth Bank for fabrication of autogenous tooth bone. Ten days later, each extraction site was implanted with MS Implant Narrow Ridge $3.0{\times}10mm$ fixture (Osstem, Seoul, Korea) after standardized 2mm-sized artificial vertical bony defect formation. Pineappleshaped Root-On type autogenous tooth bones were applied to the vertical defects around the neck area of the posterior three fixtures and the fore-most one was not applied with autogenous bone as a control group. Each minipig was sacrificed at 4, 8, 12 weeks after fixture installation and examined radiologically and histologically. Histological evaluation was done under light microscope with Villanueva osteochrome bone staining with semi-quantitative histomorphometric study. Percentage of new bone over total area (NBF) and bone to implant contact (BIC) ratio were evaluated using digital software for area calculation. Result: NBF were $48.15{\pm}18.02%$, $45.50{\pm}28.37%$, and $77.13{\pm}15.30%$ in 4, 8, and 12 weeks, respectively for experimental groups. The control group showed $37.00{\pm}11.53%$, $32.25{\pm}26.99%$, and $1.33{\pm}2.31%$ in 4,8,12 weeks, respectively. BIC ratio were $53.08{\pm}19.82%$, $45.00{\pm}28.37%$, and $75.13{\pm}16.55%$ in 4,8,12 weeks, respectively. Those for the control groups were $38.33{\pm}6.43%$, $33.50{\pm}29.51%$, and $1.33{\pm}2.31%$ in 4, 8, 12 weeks, respectively. Conclusion: Autogenous tooth bone showed higher score than control group in NBF and BIC in all the data encompassing 4,8,12 weeks specimens, but statistically significant only 12 weeks data in both NBF and BIC.

Virtual Dissection System of Cadaver Heart Using 3-Dimensional Image

  • Chung, Min-Suk;Lee, Je-Man;Kim, Min-Koo;Park, Seung-Kyu
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.357-360
    • /
    • 1997
  • For medical students and doctors, knowledge of the 3-dimensional (3D) structure of the heart is very important in diagnosis and treatment of the heart diseases. 2-dimensional (2D) tools (e.g. anatomy book) or classical 3D tools (e.g. plastic model) are not sufficient or understanding the complex structures of the heart. Moreover, it is not always guaranteed to dissect the heart of cadaver when it is necessary. To overcome this problem, virtual dissection systems of the heart have been developed. But these systems are not satisfactory since they are made of radiographs; they are not true 3D images; they can not be used to dissect freely; or they can only be operated on the workstation. It is also necessary to make the dissection systems incorporating the various races and tribes because of the organ's difference according to race and tribe. This study was intended to make the 3D image of the heart from a Korean cadaver, and to establish a virtual dissection system of the heart with a personal computer. The procedures or manufacturing this system were as follows. 1. The heart from a Korean adult cadaver was embedded with gelatin solution, and serially cross-sectioned at 1mm-thickness on a meat slicer. Pictures or 153 cross-sectioned specimens were inputted into the computer using a digital camera ($756{\times}504$ resolution, true color). 2. The alignment system was established by means of the language of IDL, and applied to align 2D images of the heart. In each of 2D images, closed curves lining clean and dirty blood pathways were drawn manually on the CorelDRAW program. 3. Using the language of IDL, the 3D image and the virtual dissection system of the heart were constructed. The virtual dissection system of the heart allowed or ree rotation, any-directional sectioning, and selected visualization of the heart's structure. This system is expected to become more advanced, and to be used widely through Internet or CD-title as an educational tool for medical students and doctors.

  • PDF

A Study on Legal Protection, Inspection and Delivery of the Copies of Health & Medical Data (보건의료정보의 법적 보호와 열람.교부)

  • Jeong, Yong-Yeub
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.1
    • /
    • pp.359-395
    • /
    • 2012
  • In a broad term, health and medical data means all patient information that has been generated or circulated in government health and medical policies, such as medical research and public health, and all sorts of health and medical fields as well as patients' personal data, referred as medical data (filled out as medical record forms) by medical institutions. The kinds of health and medical data in medical records are prescribed by Articles on required medical data and the terms of recordkeeping in the Enforcement Decree of the Medical Service Act. As EMR, OCS, LIS, telemedicine and u-health emerges, sharing and protecting digital health and medical data is at issue in these days. At medical institutions, health and medical data, such as medical records, is classified as "sensitive information" and thus is protected strictly. However, due to the circulative property of information, health and medical data can be public as well as being private. The legal grounds of health and medical data as such are based on the right to informational self-determination, which is one of the fundamental rights derived from the Constitution. In there, patients' rights to refuse the collection of information, to control recordkeeping (to demand access, correction or deletion) and to control using and sharing of information are rooted. In any processing of health and medical data, such as generating, recording, storing, using or disposing, privacy can be violated in many ways, including the leakage, forgery, falsification or abuse of information. That is why laws, such as the Medical Service Act and the Personal Data Protection Law, and the Guideline for Protection of Personal Data at Medical Institutions (by the Ministry of Health and Welfare) provide for technical, physical, administrative and legal safeguards on those who handle personal data (health and medical information-processing personnel and medical institutions). The Personal Data Protection Law provides for the collection, use and sharing of personal data, and the regulation thereon, the disposal of information, the means of receiving consent, and the regulation of processing of personal data. On the contrary, health and medical data can be inspected or delivered of the copies, based on the principle of restriction on fundamental rights prescribed by the Constitution. For instance, Article 21(Access to Record) of the Medical Service Act, and the Personal Data Protection Law prescribe self-disclosure, the release of information by family members or by laws, the exchange of medical data due to patient transfer, the secondary use of medical data, such as medical research, and the release of information and the release of information required by the Personal Data Protection Law.

  • PDF

The Improving Effect of Paeoniae Radix on Dextran Sulfate Sodium-induced Colitis in Mice (Dextran Sulfate Sodium으로 유도된 궤양성 대장염에 대한 작약의 개선 효과)

  • Myung, Noh Yil
    • Korean Journal of Plant Resources
    • /
    • v.31 no.4
    • /
    • pp.275-282
    • /
    • 2018
  • Paeoniae Radix has been used as a traditional medicine for various diseases including hepatic disease. However, the inhibitory effect of Paeoniae Radix on intestinal inflammation has not been fully understood yet. The aim of this study was to evaluate the effect of Paeoniae Radix on colitis induced by dextran sulfate sodium in mice. To investigate the protective effects of Paeoniae Radix, the colitis mice were induced by drinking water containing 5% dextran sulfate sodium for 7 days. Mice were randomized into groups receiving Paeoniae Radix (100 mg/kg), sulfasalazine (150 mg/kg) as a positive control, or water as a negative control. We evaluated the effects of Paeoniae Radix on clinical signs induced by dextran sulfate sodium, measuring weight loss, colon length, and disease activity index. Additionally, to find a possible explanation for the anti-inflammatory effects of Paeoniae Radix, we evaluated the effects of Paeoniae Radix on the interleukin-6 and cyclooxygenase-2 levels in colitis tissue. The results indicated that mice treated with dextran sulfate sodium showed measurable clinical signs, including weight loss and reduced colon length. However, Paeoniae Radix treatment significantly improved the weight loss and disease activity index as clinical symptoms. Moreover, Paeoniae Radix inhibited the interleukin-6 and cyclooxygenase-2 expression levels in colon tissues treated with dextran sulfate sodium. Taken together, the findings of this study suggest that Paeoniae Radix may be useful for treating intestinal inflammation, including ulcerative colitis.

A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.