• Title/Summary/Keyword: Digital injection

Search Result 165, Processing Time 0.029 seconds

Performance Analysis on Digital Phase Difference Measurement Techniques for Interferometer Direction Finder (인터페로미터 방향 탐지기의 디지털 위상차 측정 기법 성능 분석)

  • Kang, Jong-jin;Park, Sung-kyun;Roh, Ji-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1076-1082
    • /
    • 2018
  • This paper describes interferometer direction finder which measures the angle of arrival based on calculation of the phase difference of received radio signal from different antennas. Modern Electronic Warfare direction finder uses digital phase difference measuring techniques which have less effect on temperature variation and better performance under low Signal to Noise Ratio environment. In this paper, we analyze acceptable phase difference error for requirement of system's direction finding accuracy and introduce digital phase difference calculation techniques. We have investigated quantitative analysis on phase difference calculation according to sample number, SNR, interference injection. Through the simulation, frequency domain measurement technique is better performance than the time domain one at the environment of low SNR and interference injection. Proposed method can be used to determine the performance of interferometer direction finder.

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측)

  • Ahn, Byoung-Ha;Shim, Jae-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.

Real-Time Monitoring for Automobile Rubber Parts Manufacturing (방진고무 생산공정의 실시간 모니터링)

  • 정광조;임선종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.653-657
    • /
    • 2000
  • The paper describes the contents and results of the national project named "Development of Computer Integrated Product Design for Automation Equipment". It is focussed on the real-time control '||'&'||' monitoring of manufacturing process for automobile rubber parts. Automobile rubber parts industy is one of the typical process that high11 depends upon manufacturing facilities and equipments. So. it requires high cost and engineering technolog) on plant implementation. But most companies of rubber parts industries are small or mid companies that habe weak abilities for plant implementation properly and systematically. Therefore, for upgrading the levelof automation. it is necessar). to dekelope the computer based management and monitoring slsteni that enables to build-up the common base of automation and systemization. 'Through this project. we developed low cost real-time monitoring system for banbun mixing process '||'&'||' mold injection process of rubbcr parts manufacturing, that is composed with DDCU(Distributed Digital Control Unit),signal interfaces to gathering mon~toring terms and speciall\ developed functional sofhare including some algorithm for management '||'&'||' process monitoring

  • PDF

Radiological Evaluation of CT Contrast Medium Extravasation (CT 조영제 혈관외유출의 방사선학적 고찰)

  • Kweon, Dae-Cheol;Park, Chang-Hee;Jeong, Jae-Ho;Kang, Hui-Doo;Song, Woon-Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.39-49
    • /
    • 2008
  • Extravasation of contrast material is a not infrequent complication of enhanced imaging studies and large volume extravasation may result in severe damage. Subcutaneous extravasation of the radiographic contrast medium is one of the complications of the contrast medium-enhanced procedures. Automated power injectors enable the contrast material to be delivered at a uniform high-flow-rate and as a nonfragmented bolus, and this is essential for many contrast material enhanced CT(computed tomography) applications. The major risk associated with the use of automated power injectors is the well known complication of contrast material extravasation at the injection site. Automated injection of CT contrast material can produce the compartment syndrome. Selection of the nonionic contrast material after careful evaluation of the intravenous administration site and monitoring of the patient during the use of a mechanical power injector may help minimize or prevent extravasation injuries. Early identification is important and conservative management is effective in most cases. Prevention of these injuries with the education of radiological technologist remains the ultimate aim.

  • PDF

Computed Tomographic Findings of Navicular Syndrome in a Horse

  • Lee, Seyoung;Lee, Eun-bee;Park, Kyung-won;Jeong, Hyohoon;Kang, Tae-young;Seo, Jong-pil
    • Journal of Veterinary Clinics
    • /
    • v.38 no.2
    • /
    • pp.94-97
    • /
    • 2021
  • An 18-year-old warmblood gelding was presented to Jeju National University Equine Hospital with chronic bilateral forelimb lameness. Navicular syndrome was suspected based on clinical findings, the hoof test, palmar digital nerve block, and radiographic results. Computed tomography (CT) was performed under general anesthesia. Bone cysts, enlarged vascular channels, sclerosis, and enthesophytes were identified in the navicular bone on CT images. Mineralization in the deep digital flexor tendon was also observed. CT can be a useful diagnostic tool for identifying lesions of the navicular bone and adjacent structures in horses. The horse was treated with an intra-bursal injection of triamcinolone and gentamicin. Lameness started to improve two days later and the horse was sound after two months of the injection. CT enabled us not only to diagnosis of navicular syndrome but also to determine the degree and extent of the lesions.

The Effects of Convergence-Based Reeducation on Core Basic Nursing Skills on Nursing Students' Competence and Confidence (융복합기반 핵심기본간호술 재교육이 간호학생의 수행능력 및 자신감에 미치는 효과)

  • Jung, Myung-Sook;Kwon, Young-Sook
    • Journal of Digital Convergence
    • /
    • v.13 no.4
    • /
    • pp.295-302
    • /
    • 2015
  • The purpose of this study was to evaluate the effects of convergence-based reeducation of core basic nursing skills (subcutaneous injection, indwelling catheterization) on competence, knowledge, attitude and confidence for nursing students. Subjects were 34 nursing students and 3rd grade. Experimental treatment and data collection was conducted from December 14 to 29, 2013. Skills for subcutaneous injection including simple blood glucose test and indwelling catheterization were evaluated before and after intervention. Knowledge, attitude and confidence were measured using structured questionnaires. Data were analyzed by the frequency, descriptive statistics and paired t-test using SPSS version 21. As a result, after reeducation, significant improvement was found in competence (p<.001), knowledge (p<.001) and confidence (p<.001) in subcutaneous injection and indwelling catheterization. Convergence-Based reeducation program was found effective to enhance the competence of core basic nursing skills before graduating nursing students. Therefore, it is necessary to continue to develop program and to evaluate the effects with further research.

Spray Charateristics of Water/Oil Emulsified Fuel in Pressure-Swirl Nozzle (압력선회노즐에서 물-기름 유화연료의 분무특성)

  • Rhim, J.H.;No, S.Y.
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.5-12
    • /
    • 2000
  • The beneficial aspects of applying emulsion fuels to combustion systems may be due to the changes of fuel properties which lead to the enhanced atomization characteristics. The spray characteristics of water/oil emulsified fuel injected from the pressure-swirl(simplex) atomizer using for oil burner were investigated. Four different water contents from 10 to 40 % by volume at 10% increment were prepared by mixing with the different contents of surfactants. Total amount of surfactant used was varied from 1 to 3 % by volume. This study demonstrates the influence of water and surfactant contents of emulsified fuel, injection pressure on the spray characteristics, i.e. Sauter mean diameter(SMD) and spray angle. The drop size distribution of the emulsified fuel spray was measured with a Malvem particle sizer. In order to measure the spray angle, the digital image processing was employed by capturing multiple images of the spray with 3-CCD digital video camera. It was evident that the addition of water and surfactant changes fuel properties which are the key parameters influencing the atomization of the spray. The increase in surfactant content results in the decrease of SMD and the increase in spray angle. The droplets decease with increase in injection pressure, but the influence of injection pressure in this experimental condition was less important than expected. The more viscous fuel with the increase of water content exhibits the larger droplets in the centerline of the spray, and the less viscous fuel in the outer edges of the spray. The increase in axial position from the nozzle causes the spray angle to decrease. The spray angle decreases with increase in water content. This is due to increase in viscosity with increase in water content.

  • PDF

Characteristics of Fuel Mixing and Evaporation Based on Impingement Plate Shape in a Denitrification NOx System with a Secondary Injection Unit (2차 분사시스템을 갖는 De-NOx 시스템의 충돌판 형상에 따른 연료의 혼합 및 증발 특성 향상을 위한 연구)

  • Park, Sangki;Oh, Jungmo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.884-891
    • /
    • 2016
  • A secondary injection system in a diesel engine has benefits: it can be controlled independently without interrupting engine control, it can be adapted to various layouts for exhaust systems, and it pose no reductant dilution problems compared to post injection systems in the combustion chamber or other supplemental reductant injections. In a secondary injection system, the efficiency of the catalyst depends on the method of reducing the supply. The reductant needs to be maintained and optimized with constant pressure, the positions and angles of injector is a very important factor. The concentration and amount of reductant can be changed by adjusting secondary injection conditions. However, secondary injection is highly dependent upon the type of injector, injection pressure, atomization, spray technology, etc. Therefore, it is necessary to establish injection conditions the spray characteristics must be well-understood, such as spray penetration, sauter mean diameter, spray angle, injection quantity, etc. Uniform distribution of the reductant corresponding to the maximum NOx reduction in the DeNOx catalyst system must also assured. With this goal in mind, the spray characteristics and impingement plate types of a secondary injector were analyzed using visualization and digital image processing techniques.

A Study on the Event Processing for Electronic Control (전자제어의 Event 처리방법에 관한 연구)

  • 이종승;이중순;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.115-122
    • /
    • 1998
  • For digital engine control timings, such as ignition, are based on the crank shaft angle. Therefore, it is very important that the angle of the crank shaft can be detected with accuracy for optimal ignition timing. Sequential multi-point injection(MPI) systems that have independent injection events for each cylinder, are used to inject an accurate quantity of fuel, and to cope with varying engine status promptly. In this study the distributorless ignition timing. A crankshaft position sensor has been installed such that it generates a number of pulses per crankshaft revolution to permit accurate detection of the crank shaft angle. An event detecting algorithm has been developed, which detects the crank shaft pulses generated by the position sensor, and the software outputs the required control signals at given crank angle values. We clarified that the hardware method is the best way to increase the performance of the control system, because the event detecting duration T(1+2)max becomes zero.

  • PDF