• Title/Summary/Keyword: Digital injection

Search Result 165, Processing Time 0.023 seconds

Accuracy of Live Fluoroscopy to Detect Intravascular Injection During Lumbar Transforaminal Epidural Injections

  • Lee, Min-Hye;Yang, Kyung-Seung;Kim, Young-Hoon;Jung, Hyun-Do;Lim, Su-Jin;Moon, Dong-Eon
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Background: Complications following lumbar transforaminal epidural injection are frequently related to inadvertent vascular injection of corticosteroids. Several methods have been proposed to reduce the risk of vascular injection. The generally accepted technique during epidural steroid injection is intermittent fluoroscopy. In fact, this technique may miss vascular uptake due to rapid washout. Because of the fleeting appearance of vascular contrast patterns, live fluoroscopy is recommended during contrast injection. However, when vascular contrast patterns are overlapped by expected epidural patterns, it is hard to distinguish them even on live fluoroscopy. Methods: During 87 lumbar transforaminal epidural injections, dynamic contrast flows were observed under live fluoroscopy with using digital subtraction enhancement. Two dynamic fluoroscopy fluoroscopic images were saved from each injection. These injections were performed by five physicians with experience independently. Accuracy of live fluoroscopy was determined by comparing the interpretation of the digital subtraction fluoroscopic images. Results: Using digital subtraction guidance with contrast confirmation, the twenty cases of intravascular injection were found (the rate of incidence was 23%). There was no significant difference in incidence of intravascular injections based either on gender or diagnosis. Only five cases of intravascular injections were predicted with either flash or aspiration of blood (sensitivity = 25%). Under live fluoroscopic guidance with contrast confirmation to predict intravascular injection, twelve cases were predicted (sensitivity = 60%). Conclusions: This finding demonstrate that digital subtraction fluoroscopic imaging is superior to blood aspiration or live fluoroscopy in detecting intravascular injections with lumbar transforaminal epidural injection.

Evaluation of effectiveness of fault-tolerant techniques in a digital instrumentation and control system with a fault injection experiment

  • Kim, Man Cheol;Seo, Jeongil;Jung, Wondea;Choi, Jong Gyun;Kang, Hyun Gook;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.692-701
    • /
    • 2019
  • Recently, instrumentation and control (I&C) systems in nuclear power plants have undergone digitalization. Owing to the unique characteristics of digital I&C systems, the reliability analysis of digital systems has become an important element of probabilistic safety assessment (PSA). In a reliability analysis of digital systems, fault-tolerant techniques and their effectiveness must be considered. A fault injection experiment was performed on a safety-critical digital I&C system developed for nuclear power plants to evaluate the effectiveness of fault-tolerant techniques implemented in the target system. A software-implemented fault injection in which faults were injected into the memory area was used based on the assumption that all faults in the target system will be reflected in the faults in the memory. To reduce the number of required fault injection experiments, the memory assigned to the target software was analyzed. In addition, to observe the effect of the fault detection coverage of fault-tolerant techniques, a PSA model was developed. The analysis of the experimental result also can be used to identify weak points of fault-tolerant techniques for capability improvement of fault-tolerant techniques

A Study on Digital Process of Injection Mold in Reverse Engineering (역공학을 이용한 사출금형제작 공정에 관한 연구)

  • Lee, Hui-Gwan;Kim, Hyeong-Chan;Yang, Gyun-Ui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.160-165
    • /
    • 2002
  • A study on digital processes of injection mold in reverse engineering are presented. Reverse engineering is useful fur several cases, where user has no geometry information of object. Laser scanner is used to obtaining 3D coordinates of object. Sequences to process cloud data are described; sampling to reduce number of points, sorting to adjust the point order, and fitting to curve and surface, and so on. Split slide structure of mold is used fur undercut part and high viscosity material. Flow of injection molding are analysed to correct cooling channel and simulate molding conditions. NC tool paths are generated to carve core and cavity. The processes are performed in digital data for reduction of lead time and consecutive geometry data.

Optimized Digital Proportional Integral Derivative Controller for Heating and Cooling Injection Molding System

  • Jeong, Byeong-Ho;Kim, Nam-Hoon;Lee, Kang-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1383-1388
    • /
    • 2015
  • Proportional integral derivative (PID) control is one of the conventional control strategies. Industrial PID control has many options, tools, and parameters for dealing with the wide spectrum of difficulties and opportunities in manufacturing plants. It has a simple control structure that is easy to understand and relatively easy to tune. Injection mold is warming up to the idea of cycling the tool surface temperature during the molding cycle rather than keeping it constant. This “heating and cooling” process has rapidly gained popularity abroad. However, it has discovered that raising the mold wall temperature above the resin’s glass-transition or crystalline melting temperature during the filling stage is followed by rapid cooling and improved product performance in applications from automotive to packaging to optics. In previous studies, optimization methods were mainly selected on the basis of the subjective experience. Appropriate techniques are necessary to optimize the cooling channels for the injection mold. In this study, a digital signal processor (DSP)-based PID control system is applied to injection molding machines. The main aim of this study is to optimize the control of the proposed structure, including a digital PID control method with a DSP chip in the injection molding machine.

Experimental Study on the Characteristics of Micro Jet Flow Using Digital Microscopic Holography (디지털 현미경 홀로그래피 기법을 이용한 마이크로 액체 제트 유동에 관한 실험적 연구)

  • Lee, Haneol;Lee, Jaiho;Shin, Weon Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.48-53
    • /
    • 2018
  • In this study, the effect of injection pressure on the column diameter and droplet velocity of liquid jet with the weakly turbulent Rayleigh-like breakup mode is experimentally studied using digital microscopic holography (DMH). The injection nozzle has the diameter of $50{\mu}m$ and injection pressure is varied from 0.1 to 0.4 MPa. When the micro liquid jet is injected into still air, the double-pulsed holograms was recorded on a CCD sensor and numerically reconstructed in order to obtain well focused images. In this study, the liquid column diameter from $50{\mu}m$ orifice nozzle is shown to be changed slightly but the droplet velocity is increased proportionally as the injection pressure is increased.

Comparison of pain relief in soft tissue tumor excision: anesthetic injection using an automatic digital injector versus conventional injection

  • Hye Gwang Mun;Bo Min Moon;Yu Jin Kim
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.1
    • /
    • pp.17-21
    • /
    • 2024
  • Background: The pain caused by local anesthetic injection can lead to patient anxiety prior to surgery, potentially necessitating sedation or general anesthesia during the excision procedure. In this study, we aim to compare the pain relief efficacy and safety of using a digital automatic anesthetic injector for local anesthesia. Methods: Thirty-three patients undergoing excision of a benign soft tissue tumor under local anesthesia were prospectively enrolled from September 2021 to February 2022. A single-blind, randomized controlled study was conducted. Patients were divided into two groups by randomization: the experimental group with digital automatic anesthetic injector method (I-JECT group) and the control group with conventional injection method. Before surgery, the Amsterdam preoperative anxiety information scale was used to measure the patients' anxiety. After local anesthetic was administered, the Numeric Pain Rating Scale was used to measure the pain. The amount of anesthetic used was divided by the surface area of the lesion was recorded. Results: Seventeen were assigned to the conventional group and 16 to the I-JECT group. The mean Numeric Pain Rating Scale was 1.75 in the I-JECT group and 3.82 in conventional group. The injection pain was lower in the I-JECT group (p< 0.01). The mean Amsterdam preoperative anxiety information scale was 11.00 in the I-JECT group and 9.65 in conventional group. Patient's anxiety did not correlate to injection pain regardless of the method of injection (p= 0.47). The amount of local anesthetic used per 1 cm2 of tumor surface area was 0.74 mL/cm2 in the I-JECT group and 2.31 mL/cm2 in the conventional group. The normalization amount of local anesthetic was less in the I-JECT group (p< 0.01). There was no difference in the incidence of complications. Conclusion: The use of a digital automatic anesthetic injector has shown to reduce pain and the amount of local anesthetics without complication.

Study on the Design Optimization to Improve Injection Molding Performance of Plastic Regulator Rail (플라스틱 레귤레이터 레일 성형 최적화연구)

  • Lee, Haeng-Soo;Byun, Hong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5709-5715
    • /
    • 2012
  • Injection molding product is commonly used for reducing the weight of automotive vehicle, and door regulator guide rail with plastic material is also made by injection molding process. In order to improve the injection molding performance of plastic regulator guide rail, optimal molding condition is suggested by numerical simulation and DOE after obtaining the sensitivity of parameters for regulator rail manufacturing on warpage and fill time. Furthermore, multi direct gate method and optimal cooling circuit are introduced to get the uniform temperature distribution and better cooling efficiency in molding product. The effect of the proposed design on the injection molding performance is verified by the test of prototype of plastic regulator guide rail.

The need and application examples of 3D Flow Analysis in the industry (산업현장에서의 3차원 성형해석의 필요성 및 적용예제)

  • Lee, Gil-Ho;Yamada, Takemitsu
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.11a
    • /
    • pp.217-220
    • /
    • 2004
  • 3D CAE becomes a key technology to complete a digital engineering system. '3D TIMON', developed by TORAY Industries, Inc., is the useful software to analyze whole injection molding process with solid elements and is capable of generating solid mesh models directly from 3D CAD data. In this paper, we introduce '3D TIMON' and the application examples in the each industries.

  • PDF

EXPERIMENTAL STUDY ON THE FLOW AND MIXTURE DISTIBUTION IN A VISUALIZATION ENGINE USING DIGITAL PARTICLE IMAGE VELOCIMETRY AND ENTROPY ANALYSIS

  • Lee, K.H.;Lee, C.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2007
  • The objective of this study is to analyze the effect of velocity and vorticity on stratified mixture formation in the visualization engine. In order to investigate spray behavior, the pray velocity is obtained through the cross-correlation PIV method, a useful optical diagnostics technology and the vorticity calculated from the spray velocity component. These results elucidated the relationship between vorticity and entropy, which play an important role in the diffusion process for the early injection case and the stratification process for the late injection case. In addition, we quantified the homogeneous diffusion ate of spray using entropy analysis based on Boltzmann's statistical thermodynamics. Using these methods, we discovered that the homogeneous mixture distribution is more effective as a momentum dissipation of surrounding air than that of the spray concentration with a change in the injection timing. We found that the homogenous diffusion rate increased as the injection timing moved to the early intake stroke process, and BTDC $60^{\circ}$ was the most efficient injection timing for the stratified mixture formation during the compression stroke.

Digital subtraction angiography vs. real-time fluoroscopy for detection of intravascular injection during transforaminal epidural block

  • Park, Kibeom;Kim, Saeyoung
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.109-114
    • /
    • 2019
  • Background: Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF. Methods: We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA. Results: Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels. Conclusion: During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.