• 제목/요약/키워드: Digital Radiography Test

검색결과 86건 처리시간 0.026초

용접구조물의 최신 비파괴 검사기술 (Latest Technology of Non Destructive Inspection for Welded Structure)

  • 김영식;길상철
    • Journal of Welding and Joining
    • /
    • 제35권2호
    • /
    • pp.63-70
    • /
    • 2017
  • As the Non Destructive Test (NDT) for the welded structure, PT(Penetration Test). MT(Magnetic Test), RT (Radioisotope Test) and UT(Ultrasonic Test) methods are widely used in practice. These NDT methods have been developed toward high efficiency, low cost, real time, and high precise new NDT. For example, RT methods are developed to CT(Computed Tomography)and DR(Digital Radiography), and UT metheds are developed into Phased array, Guide wave, TOFD method. Moreover, the Infrared thermography and Laser ultrasonic technique are newly developed for applying in high temperature objects as the non-contact NDT methods. In this review paper the new high efficiency NDT methods for the welded structure are introduced and the trend of NDT rules applying in welded structure are described.

보일러튜브 용접부 비파괴검사를 위한 컴퓨터화 방사선투과시험 적용 연구 (Application of Computed Radiography for Nondestructive Testing of Boiler Tube Weldments)

  • 박상기;안연식;길두송
    • 동력기계공학회지
    • /
    • 제13권5호
    • /
    • pp.95-102
    • /
    • 2009
  • A steam generator (boiler) in thermal power plants, consisting of more than 30,000 parts and components, can lead to the plant shutdown with damage to even the small part of the components; esp., like weld failures on boiler tubes. Consequently it is greatly demanded to improve the quality of the weld on the boiler tube for the stable operation of the power plants. Because of the feature of the welding, which is done past by melting the work pieces and adding a filler material that cools to become a strong coalescence, there is a great possibility that weld failures take place. As a result, it is regulated to make a non-destructive testing, like radiography test, to detect defects and flaws in the weld. The current film radiography test provides a lower image quality exceeding 2.0% of a basic quality level for a penetrameter, it is very likely to fail to detect micro defect. As a result, the prevention for the boiler tube failure has not been made effectively. In this study, computed radiography technology has been applied as a digital radiography test to the boiler tube weld, and Se-75 radiation source was used to improve the image quality, instead of Ir-192 source. As a result of this study, it is proven to save the time and cost for test and to enhance the quality level of penetrameter penetrating image, which enables to upgrade the quality of radiography test to the boiler tube weld.

  • PDF

2급 치근이개부 치료 시 흡수성 차폐막, 동종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석 (An Assessment on effect of Bioabsorbable membrane, allogenic bone and Platelet Rich Plasma in Class II furcation involvement by digital subtraction radiography)

  • 김상훈;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.173-186
    • /
    • 2002
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)) in humans by digital subtraction radiography. 12 teeth(control group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)), and 12 teeth(test group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)), bioabsorable membrane(BioMesh(R)) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program (5% significance level). The results were as follows: 1. In test group, the radiopacity in 3 months after surgery were significantly increased than 1 month after surgery(p<0.05). However. there were no significant difference between 1 month after surgery and 3 months after surgery in control group(p>0.05). 2. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 1 month after surgery(p<0.05) 3. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

2급 치근 이개부 치료 시 합성골 이식 및 혈소판 농축 혈장의 골재생 효과에 대한 디지털 공제술의 정량적 분석 (The Quantitative Analysis by Digital Subtraction Radiography on the Effect of Platelet Rich Plasma Combined with Synthetic Bone Graft on Grade II Furcation Involvement)

  • 오지수;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제31권2호
    • /
    • pp.465-475
    • /
    • 2001
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with and without porous resorbable calcium carbonate($Biocoral^{(R)}$)in humans by digital subtraction radiography. 15 teeth(control group) were treated with porous resorbable calcium carbonate($Biocoral^{\(R)}$), and 15 teeth(test group) were treated with porous resorbable calcium carbonate($Biocoral^{(R)}$) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program(5% significance level). The results were as follows: 1. In test group, the radiolucency in 3 months after surgry were significantly increased than 1 month after surgery(p<0.05). 2. In test group, there were no significant difference between 1 month after surgery and 6 months after surgery(p>0.05). 3. In test group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. In control group, the radiolucency in 3 months and 6 months after surgery were significantly increased than 1 month after surgery(p<0.05). 5. In control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 6. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

  • PDF

디지털공제방사선촬영술을 이용한 치근단 흡수의 평가 (Assessment of apical root resorption using digital subtraction radiography)

  • 허민석;이삼선;이경희;최항문;최순철;박태원
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.51-55
    • /
    • 2001
  • Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.

  • PDF

일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구 (The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography)

  • 이양구;양원식;장영일
    • 대한치과교정학회지
    • /
    • 제32권2호통권91호
    • /
    • pp.79-89
    • /
    • 2002
  • 본 연구의 목적은 일반두부방사선계측사진과 디지털두부방사선계측사진의 계측점 식별의 오차를 구하여 각각의 영상에서 오차의 특징을 살펴보고 재현성을 비교 평가하는 것이다. 연구 대상은 서울대학교병원 치과진료부 교정과에 내원한 교정 환자 중 18세에서 29세 사이의 성인 환자 중에서 일반두부방사선계측사진군과 디지털두부방사선계측사진군 각각 15명씩 30명을 무작위로 선택하여 연구 대상으로 하였으며 남녀의 구별이나 두개 안면 구조의 형태는 고려하지 않았다. 계측점은 동일인이 시간차를 두고 식별 하였다. 식별 후 각 계측점은 좌표 (x, y)로 표시하였으며, 처음 계측점을 식별한 두부방사선계측사진군을 T1으로, 1 주 후 동일 계측점을 재식별한 두부방사선계측사진군을 T2로, 1 달 후 동일계측점을 재식별한 두부방사선계측사진군을 T3로 분류하였다. 오차의 평균과 표준편차는 x좌표, y좌표로 구분하여 계산하였다. 초기 식별 1주 후 재식별시 오차는 T2-T1(x), T2-T1(y)로, 초기 측정 1달 후 재시별시 오차는 T3-T1(x), T3-T1(y)로 표시하였으며 일반두부방사선계측사진과 디지털두부방사선계측사진으로 각각 나누었다. 재현성의 평가를 위한 오차간의 통계학적인 검정은 independent t-test를 사용하였으며 다음과 같은 결론을 얻었다. 1. 디지털두부방사선계측사진이 일반두부방사선계측사진보다 일반적으로 오차의 평균 및 표준편차가 작았다. 2. 일반두부방사선계측사진의 오차와 디지털두부방사선계측사진의 오차가 통계학적으로 유의성 있는 차이를 보인 항목은 드물었다. 3.상의 향상을 통한 오차의 개선은 한계가 있었으며 상이 향상되더라도 각 계측점의 오차 의 경향은 크게 변하지 않았다.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교 (Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds)

  • 양진욱;조갑호;남문호
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.585-594
    • /
    • 2022
  • 현재 주로 사용되고 있는 디지털 방사선 검사용 검출기는 평면형의 구조를 가진 검출기로 이루어져 있어 곡률을 가진 검사 대상물의 디지털 방사선 검사 시 완전한 밀착이 불가능 하였다. 본 연구는 산업현장에서 배관 용접부를 대상으로 한 디지털 방사선 투과 검사 시 디지털 영상의 상질 개선을 위하여 곡률에 밀착이 가능한 커브드 형태의 검출기를 제작하였고, 공칭 두께가 각기 다른 6" 배관을 대상으로 평면형 검출기와 커브드 검출기를 사용한 디지털 방사선 영상을 획득하였다. 실험 결과, 평면형 검출기는 배관과 완전한 밀착이 되지 않아 배관 외곽부와 검출기 사이의 틈이 생기게 되고, 이로 인해 불선명도 차이가 생기면서 디지털 영상의 확산이 발생하는 것을 확인하였다. 반면, 커브드형 검출기는 배관 외곽부와 검출기 사이의 틈을 최소화 하여 평면형 검출기에 비해 디지털 영상의 확산이 적은 것을 확인하였다. 영상의 확신이 클수록 상질의 저하 및 판독의 오류가 발생할 수 있기 때문에 검사 대상물과 밀착이 가능한 검출기의 사용시 기존 평면형 검출기 보다 양질의 영상을 획득 가능할 것으로 사료된다.

다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구 (The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$)

  • 최장용;이동길;신정욱;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF