• Title/Summary/Keyword: Digital Optical Method

Search Result 391, Processing Time 0.029 seconds

Real-Time Digital Auto-Focusing Using A-Priori Estimated Point Spread Functions (점 확산 함수 데이터베이스를 이용한 실시간 디지털 자동초점)

  • Yoo Yoon-Jong;Lee Jung-Soo;Shin Jeong-Ho;Paik Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.5 s.311
    • /
    • pp.1-11
    • /
    • 2006
  • This paper presents a digital auto-focusing method using a priori estimated point-spread-functions (PSF) database. The proposed algorithm efficiently removes out-of-focus blur in a degraded input image by selecting the optimal PSF from the database. The database consists of optical characteristics of image formation system. The PSF selection Process is performed based on a novel focusing measure. The proposed method includes a spatially adaptive filter for removing both noise and ringing artifacts. Experimental results show that the proposed method efficiently removes out-of-focus blur using significantly reduced computational load compared with the existing method.

Analysis of the Digital Phase Tracking Technique for Fiber-Optic Gyroscope (광섬유 자이로스코프의 위상추적 신호처리 분석)

  • Yeh, Y.H.;Cho, S.M.;Kim, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.95-105
    • /
    • 1997
  • A new open-loop signal processing technique of digital phase tracking is known to have a Potential to solve the problems in the open-loop processor such as limited dynamic range, dependence on the optical intensity fluctuations, and dependence on gain fluctuations of signal path. But new problems with digital phase tracking must be solved before it can be a useful signal processing method. In this paper, barriers to the success of the digital phase tracking such as harmonics content, phase difference, amplitude variations of the phase modulation(PM) signal, bandwidth limit of the signal path, and the implementation of the mixer, are pointed out and their effects on the performance of the signal processor are analyzed to calculate the requirements of the signal processor for $1{\mu}rad$-grade FOG.

  • PDF

Development of an Algorithm for Detecting Angular Bisplacement with High Accuracy Based on the Dual-Encoder (이중 증분 엔코더에 기초한 초정밀 회전각도 변위 검출 알고리즘 개발)

  • Lee, Se-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.29-36
    • /
    • 2008
  • An optical rotary encoder is easy to implement for automation system applications. In particular, the output of the encoder has a digital form pulse, which is also easy to be connected to a popular digital controller. By using an incremental encoder and a counting device, it is easy to measure angular displacement, as the number of the output pulses is proportional to the rotational displacement. This method can only detect the angular placement once a pulse signal comes out of the encoder. The angular displacement detection period is strongly subject to the change of the angular displacement in case of ultimate low velocity range. They have ultimate long detection period or cannot even detect angular displacement at near zero velocity. This paper proposes an algorithm for detecting angular displacement by using a dual encoder system with two encoders of normal resolution. The angular displacement detecting algorithm is able to keep detection period moderately at near zero velocity and even detect constant angular displacement within nominal period. It is useful for motion control applications in case of changing rotational direction at which there occurs zero velocity. In this paper, various experimental results are shown for the angular displacement detection algorithm.

A Study on Two-wavelength Digital Holography Using the Fresnel-Bluestein Transform (프레즈넬-불루스타인 변환을 이용한 2파장 디지털 홀로그래픽 연구)

  • Shin, Sanghoon;Kim, Doocheol;Yu, Younghun
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.251-254
    • /
    • 2012
  • Dual-wavelength holography has a better axial range than single-wavelength holography, allowing unambiguous phase imaging. The size of a reconstructed image depends on the reconstruction distance and wavelength. The two phase image sizes of different wavelength holograms should be the same in order to apply dual-wavelength holography. The Fresnel-Bluestein transform method is proposed to eliminate the dependence on the reconstruction distance and wavelength. We found that the Fresnel-Bluestein transform is very useful for making different reconstructed image sizes experimentally. Also we applied the Fresnel-Bluestein transform to make the same reconstruction image size in dual wavelength holography.

Spatial augmented reality for product appearance design evaluation

  • Park, Min Ki;Lim, Kyu Je;Seo, Myoung Kook;Jung, Soon Jong;Lee, Kwan H.
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.38-46
    • /
    • 2015
  • Augmented reality based on projection, called "Spatial Augmented Reality (SAR)", is a new technology that can produce immersive contents by overlapping virtuality and real-world environment. It has been paid attention as the next generation digital contents in media art and human-computer interaction (HCI). In this paper, we present a new methodology to evaluate the product appearance design more intuitively by means of SAR technique. The proposed method first projects the high-quality rendered image considering the optical property of materials onto the mock-up of a product. We also conduct a projector-camera calibration to compensate a color distortion according to a projector, a projection surface and environment lighting. The design evaluation methodology we propose offers more flexible and intuitive evaluation environment to a designer and user (evaluator) than previous methods that are performed via a digital display. At the end of this research, we have conducted a case study for designing and evaluating appearance design of an automobile.

Performance Evaluation of Digital Radiography Antiscatter Grids using Film Digitizers

  • Lee, Hyoung-Koo;Lee, Jung-Ae;Kim, Sung-Hyun;Ho, Dong-Su;Kim, Do-Il;Suh, Tae-Suk;Choe, Bo-Young;Kim, Jin-Soo;Kim, Jin-Won
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.393-395
    • /
    • 2002
  • We propose a method which can replace the DR when measuring performance evaluation parameters of antiscatter grids for DR. We used conventional x-ray films to produce grid images, which were scanned by a film digitizer. The digitizer could provide sampling interval of 87 micrometers and pixel depth of 12 bits. Grid line frequencies were measured using aliasing effect and non-uniformities of grids were measured by transforming scanned pixel values of film images into optical densities.

  • PDF

EXPERIMENTAL STUDY ON THE FLOW AND MIXTURE DISTIBUTION IN A VISUALIZATION ENGINE USING DIGITAL PARTICLE IMAGE VELOCIMETRY AND ENTROPY ANALYSIS

  • Lee, K.H.;Lee, C.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2007
  • The objective of this study is to analyze the effect of velocity and vorticity on stratified mixture formation in the visualization engine. In order to investigate spray behavior, the pray velocity is obtained through the cross-correlation PIV method, a useful optical diagnostics technology and the vorticity calculated from the spray velocity component. These results elucidated the relationship between vorticity and entropy, which play an important role in the diffusion process for the early injection case and the stratification process for the late injection case. In addition, we quantified the homogeneous diffusion ate of spray using entropy analysis based on Boltzmann's statistical thermodynamics. Using these methods, we discovered that the homogeneous mixture distribution is more effective as a momentum dissipation of surrounding air than that of the spray concentration with a change in the injection timing. We found that the homogenous diffusion rate increased as the injection timing moved to the early intake stroke process, and BTDC $60^{\circ}$ was the most efficient injection timing for the stratified mixture formation during the compression stroke.

QR code as speckle pattern for reinforced concrete beams using digital image correlation

  • Krishna, B. Murali;Tezeswi, T.P.;Kumar, P. Rathish;Gopikrishna, K.;Sivakumar, M.V.N.;Shashi, M.
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.1
    • /
    • pp.67-84
    • /
    • 2019
  • Digital Image Correlation technique (DIC) is a non-contact optical method for rapid structural health monitoring of critical infrastructure. An innovative approach to DIC is presented using QR (Quick Response) code based random speckle pattern. Reinforced Cement Concrete (RCC) beams of size $1800mm{\times}150mm{\times}200mm$ are tested in flexure. DIC is used to extract Moment (M) - Curvature (${\kappa}$) relationships using random speckle patterns and QR code based random speckle patterns. The QR code based random speckle pattern is evaluated for 2D DIC measurements and the QR code speckle pattern performs satisfactorily in comparison with random speckle pattern when considered in the context of serving a dual purpose. Characteristics of QR code based random speckle pattern are quantified and its applicability to DIC is explored. The ultimate moment-curvature values computed from the QR code based random speckled pattern are found to be in good agreement with conventional measurements. QR code encrypts the structural information which enables integration with building information modelling (BIM).

Vignetting Dimensional Geometric Models and a Downhill Simplex Search

  • Kim, Hyung Tae;Lee, Duk Yeon;Choi, Dongwoon;Kang, Jaehyeon;Lee, Dong-Wook
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • Three-dimensional (3D) geometric models are introduced to correct vignetting, and a downhill simplex search is applied to determine the coefficients of a 3D model used in digital microscopy. Vignetting is nonuniform illuminance with a geometric regularity on a two-dimensional (2D) image plane, which allows the illuminance distribution to be estimated using 3D models. The 3D models are defined using generalized polynomials and arbitrary coefficients. Because the 3D models are nonlinear, their coefficients are determined using a simplex search. The cost function of the simplex search is defined to minimize the error between the 3D model and the reference image of a standard white board. The conventional and proposed methods for correcting the vignetting are used in experiments on four inspection systems based on machine vision and microscopy. The methods are investigated using various performance indices, including the coefficient of determination, the mean absolute error, and the uniformity after correction. The proposed method is intuitive and shows performance similar to the conventional approach, using a smaller number of coefficients.

Electrochemical Monitoring of NADH Redox with NPQD-modified Electrodes for Cell Viability Assessment

  • JuKyung Lee;Hye Bin Park;Chae Won Seo;Chae Won Seo;SangHee Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.412-417
    • /
    • 2023
  • There is increasing interest in the rapid and highly sensitive monitoring of cell viability in biological and toxicological research. Conventional methods depend on optical assays using Water Soluble Tetrazolium-8 (WST-8) or 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) assay, which requires a large volume of samples and special instruments, necessitating shipment of clinical samples to laboratories. This paper reports on the development of a rapid and sensitive electrochemical (EC) sensor using screen printed electrode (SPE) and surface modification using 4'-mercapto-N-phenylquinone diamine (4'-NPQD), as double electron mediators, for monitoring cell viability via the measurement of nicotinamide adenine dinucleotide (NADH). We used the sensor to observe the viability of MCF-7 and doxorubicin (Dox)-treated cells. The oxidation current of NADH was measured via chronoamperometry (CA), and the EC results showed a good linear relationship when compared with NADH quantification using WST-8 assay. The analysis time was only 10 s and limit of detection (LOD) of NADH was 1.78 µM. Our EC method has the potential to replace conventional WST assays for cell viability and cytotoxicity experiments.