• Title/Summary/Keyword: Digital Optical Method

Search Result 391, Processing Time 0.031 seconds

Error Analysis for Optical Security by means of 4-Step Phase-Shifting Digital Holography

  • Lee, Hyun-Jin;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.118-123
    • /
    • 2006
  • We present an optical security method for binary data information by using 4-step phase-shifting digital holography and we analyze tolerance error for the decrypted data. 4-step phase-shifting digital holograms are acquired by moving the PZT mirror with equidistant phase steps of ${\pi}/2$ in the Mach-Zender type interferometer. The digital hologram in this method is a Fourier transform hologram and is quantized with 256 gray level. The decryption performance of the binary data information is analyzed. One of the most important errors is the quantization error in detecting the hologram intensity on CCD. The greater the number of quantization error pixels and the variation of gray level increase, the more the number of error bits increases for decryption. Computer experiments show the results for encryption and decryption with the proposed method and show the graph to analyze the tolerance of the quantization error in the system.

2-step Phase-shifting Digital Holographic Optical Encryption and Error Analysis

  • Jeon, Seok-Hee;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.244-251
    • /
    • 2011
  • We propose a new 2-step phase-shifting digital holographic optical encryption technique and analyze tolerance error for this cipher system. 2-step phase-shifting digital holograms are acquired by moving the PZT mirror with phase step of 0 or ${\pi}$/2 in the reference beam path of the Mach-Zehnder type interferometer. Digital hologram with the encrypted information is Fourier transform hologram and is recorded on CCD camera with 256 gray-level quantized intensities. The decryption performance of binary bit data and image data is analyzed by considering error factors. One of the most important errors is quantization error in detecting the digital hologram intensity on CCD. The more the number of quantization error pixels and the variation of gray-level increase, the more the number of error bits increases for decryption. Computer experiments show the results to be carried out encryption and decryption with the proposed method and the graph to analyze the tolerance of the quantization error in the system.

One-time Pattern Mutual Authentication Method by using Digital Holography (디지털 홀로그래피를 이용한 one-time pattern 상호 인증 방법)

  • Gil, Sang-Keun
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.291-294
    • /
    • 2016
  • A new optical one-time pattern password(OTPT) mutual authentication method is proposed, which presents a two-factor authentication by 2-step phase-shifting digital holography and performs a two-way authentication by a challenge-response handshake of the optical OTPT in both directions. Because a client and a server use OTPT once as a random number and encrypt it for mutual authentication, it protects against a replay or a man-in-the middle attack and results in higher security level.

An Iterated Optical Flow Estimation Method for Automatically Tracking and Positioning Homologous Points in Video Image Sequences

  • Tsay, Jaan-Rong;Lee, I-Chien
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.372-374
    • /
    • 2003
  • The optical flow theory can be utilized for automatically tracking and positioning homologous points in digital video (DV) image sequences. In this paper, the Lucas-Kanade optical flow estimation (LKOFE) method and the normalized cross-correlation (NCC) method are compared and analyzed using the DV image sequences acquired by our SONY DCRPC115 DV camera. Thus, an improved optical flow estimation procedure, called 'Iterated Optical Flow Estimation (IOFE)', is presented. Our test results show that the trackable range of 3${\sim}$4 pixels in the LKOFE procedure can be apparently enlarged to 30 pixels in the IOFE.

  • PDF

Investigation of Strain Measurements using Digital Image Correlation with a Finite Element Method

  • Zhao, Jian;Zhao, Dong
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.399-404
    • /
    • 2013
  • This article proposes a digital image correlation (DIC) strain measurement method based on a finite element (FE) algorithm. A two-step digital image correlation is presented. In the first step, the gradient-based subpixels technique is used to search the displacements of a region of interest of the specimen, and then the strain fields are obtained by utilizing the finite element method in the second step. Both simulation and experiment processing, including tensile strain deformation, show that the proposed method can achieve nearly the same accuracy as the cubic spline interpolation method in most cases and higher accuracy in some cases, such as the simulations of uniaxial tension with and without noise. The results show that it also has a good noise-robustness. Finally, this method is used in the uniaxial tensile testing for Dahurian Larch wood specimens with or without a hole, and the obtained strain values are close to the results which were obtained from the strain gauge and the cubic spline interpolation method.

Forming a Fresnel Zone Lens: Effects of Photoresist on Digital-micromirror-device Maskless Lithography with Grayscale Exposure

  • Huang, Yi-Hsiang;Jeng, Jeng-Ywan
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.127-132
    • /
    • 2012
  • This study discusses photoresist forming using a composite grayscale to fabricate a Fresnel lens. Grayscale lithography is a common production method used to facilitate the forming of lenses with different curvatures and depths. However, this approach is time consuming and expensive. This study proposes a method for overcoming these obstacles by integrating a digital micromirror device and microscope to supplant the traditional physical grayscale mask. This approach provides a simple and practical maskless optical lithography system. According to the results, the two adjacent grayscales displayed substantial differences between the high grayscale and influence the low grayscale that ultimately affected photoresist formation. Furthermore, we show that change of up to 150% in the slope can be achieved by changing the grayscale gradient in the central zone and the ring profile. The results of the optical experiment show a focus change with different gray gradients.

Determining Two-Sided Surface Profiles of Micro-Optical Elements Using a Dual-Wavelength Digital Holographic Microscope With Liquids

  • Lee, Hong Seok;Shin, Sanghoon;Lee, Heonjoo;Yu, Younghun
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.495-499
    • /
    • 2014
  • In this paper, a method is proposed for simultaneously measuring the front and back surface profiles of transparent micro-optical components. The proposed method combines a dual-wavelength digital holographic microscope with liquids to record holograms at different wavelengths, and then numerically reconstructs the three-dimensional phase information to image the front and back sides of the sample. A theoretical model is proposed to determine the surface information, and imaging of an achromatic lens is demonstrated experimentally. Unlike conventional interferometry, our proposed method supports nondestructive measurement and direct observation of both front and back profiles of micro-optical elements.

Proposal for Analog Signature Scheme Based on RSA Digital Signature Algorithm and Phase-shifting Digital Holography

  • Gil, Sang Keun
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.483-499
    • /
    • 2020
  • In this paper, a novel analog signature scheme is proposed by modifying an RSA-based digital signature scheme with optical phase-shifting digital holography. The purpose of the proposed method is generating an analog signature to provide data confidentiality and security during the data transfer, compared to the digital signature. The holographic encryption technique applied to a hash value reveals an analog-type of pseudo-random pattern in the analog signature scheme. The public key and secret key needed to verify the analog signature are computed from public key ciphers which are generated by the same holographic encryption. The proposed analog signature scheme contains a kind of double encryption in the process of generating signature and key, which enhances security level more than the digital signature. The results of performance simulations show the feasibility of the highly secure signature scheme, and security analysis shows high robustness against known-message attacks and chosen-message attacks. In addition, the proposed method can apply to one-time signature schemes which can be used to sign only one message and it can also apply to authentication, e-mails, electronic banking and electronic data interchange.

Design of Turbidity Measurement of White Plume using Optical Method (광학기법을 이용한 백색 굴뚝연기 혼탁도 측정의 설계)

  • Son, Hyun-Keun;Ban, Chae-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1195-1200
    • /
    • 2020
  • The DOM (: Digital Optical Method), which measures the turbidity of chimney smoke, is a method of calculating the turbidity by setting the area to be measured and the contrast area using a low-cost digital camera that can be easily obtained. However, it is difficult to measure clouds and white smoke in a cloudy sky. In this paper, we develop a background sky type model that can represent the background sky and classify the type by periodically photographing it with a digital camera to solve this problem. In addition, based on the model, we develop a filter to optimize white smoke image and prove its excellence through experiments.

Optical Design and Fabrication of a Large Telephoto Zoom Lens with Fixed f/2.8 and Light Autofocus Lens

  • Ryu, Jae Myung;Gang, Geon Mo;Lee, Hyuck Ki;Lee, Ki Woo;Heu, Min;Jo, Jae Heung
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.629-637
    • /
    • 2015
  • Compact system cameras (CSCs) are commonly used nowadays and feature enhanced video functions and thin yet light interchangeable lenses. They differ from digital single-lens reflex (DSLR) cameras in their lack of mirror boxes. CSCs, however, have autofocus (AF) speeds lower than those of conventional DSLRs, requiring weight reduction of their AF groups. To ensure the marketability of large telephoto zoom lenses with fixed f/2.8 regardless of field angle variation, in particular, light weight AF groups are essential. In this paper, we introduce a paraxial optical design method and present a new, large, telephoto zoom lens with f/2.8 regardless of the field angle variation, plus a lightweight AF group consisting of only one lens. Using the basic paraxial optical design and optimization methods, we fabricated a new and lighter zoom lens system, including a single-lens, lightweight AF group with almost the same performance.