• Title/Summary/Keyword: Digital Imaging Sensor

Search Result 85, Processing Time 0.022 seconds

Generation of Simulated Geospatial Images from Global Elevation Model and SPOT Ortho-Image

  • Park, Wan Yong;Eo, Yang Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.3
    • /
    • pp.217-223
    • /
    • 2014
  • With precise sensor position, attitude element, and imaging resolution, a simulated geospatial image can be generated. In this study, a satellite image is simulated using SPOT ortho-image and global elevation data, and the geometric similarity between original and simulated images is analyzed. Using a SPOT panchromatic image and high-density elevation data from a 1/5K digital topographic map data an ortho-image with 10-meter resolution was produced. The simulated image was then generated by exterior orientation parameters and global elevation data (SRTM1, GDEM2). Experimental results showed that (1) the agreement of the image simulation between pixel location from the SRTM1/GDEM2 and high-resolution elevation data is above 99% within one pixel; (2) SRTM1 is closer than GDEM2 to high-resolution elevation data; (3) the location of error occurrence is caused by the elevation difference of topographical objects between high-density elevation data generated from the Digital Terrain Model (DTM) and Digital Surface Model (DSM)-based global elevation data. Error occurrences were typically found at river boundaries, in urban areas, and in forests. In conclusion, this study showed that global elevation data are of practical use in generating simulated images with 10-meter resolution.

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.

Serial line multiplexing method based on bipolar pulse for PET

  • Kim, Yeonkyeong;Choi, Yong;Kim, Kyu Bom;Leem, Hyuntae;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3790-3797
    • /
    • 2021
  • Although the individual channel readout method can improve the performance of PET detectors with pixelated photo-sensors, such as silicon photomultiplier (SiPM), this method leads to a significant increase in the number of readout channels. In this study, we proposed a novel multiplexing method that could effectively reduce the number of readout channels to reduce system complexity and development cost. The proposed multiplexing circuit was designed to generate bipolar pulses with different zero-crossing points by adjusting the time constant of the high-pass filter connected to each channel of a pixelated photo-sensor. The channel position of the detected gamma-ray was identified by estimating the width between the rising edge and the zero-crossing point of the bipolar pulse. In order to evaluate the performance of the proposed multiplexing circuit, four detector blocks, each consisting of a 4 × 4 array of 3 mm × 3 mm × 20 mm LYSO and a 4 × 4 SiPM array, were constructed. The average energy resolution was 13.2 ± 1.1% for all 64 crystal pixels and each pixel position was accurately identified. A coincidence timing resolution was 580 ± 12 ps. The experimental results indicated that the novel multiplexing method proposed in this study is able to effectively reduce the number of readout channels while maintaining accurate position identification with good energy and timing performance. In addition, it could be useful for the development of PET systems consisting of a large number of pixelated detectors.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

A Study on the Development of High-sensitivity AEC-sensor for Minimization of Dose Creep in Diagnostic Imaging System (진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구)

  • Kim, Kyo-Tae;Han, Moo-Jae;Heo, Ye-Ji;Kim, Joo-Hee;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.321-325
    • /
    • 2016
  • Dose creep is one of clinical errors that arises from the tester's inexperience or carelessness, and according to Task Group #116 of American Association of Physicists in Medicine, its continued occurrence is being reported in the digital method. At this point, the demand for an automatic exposure control device that minimizes the dose creep phenomenon and can improve reproducibility is increasing. In this study is to consider the automatic exposure control device sensor that can is not only easy to produce, but also reduce the dose creep phenomenon by conducting a research on high-efficient semiconductor sensor. As a result, the Intrinsic-type and PIN-type sensors have excellent optical property compared to Ref sensor, would have less shading effect, and have relatively low sensitivity, but would provide accurate feedback signals to automatic exposure control device with its consistent tendency according to exposure condition changes.

Measurement of the Photon Fluence for the Evaluation of Photon Detection Efficiency of Photon Counting Sensor (광계수형 센서의 포톤계수효율 평가를 위한 포톤플루엔스 측정)

  • Park, Ji-Koon;Heo, Ye-Ji;Kim, Kyo-Tae;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, the various digital X-ray imaging devices using CCD and TFT LCD-based flat panel digital X-ray sensor are being used. In particular, a number of studies on photon counting sensor technique have been reported. In this study, the incident X-rays fluence on the photon counting sensor material was measured to estimate photon detection efficiency which is the quantitative performance evaluation factor of photon counting sensor. The result of measuring the photon fluence by using RQA-M2 Radiation beam quality of IEC 61223-1-2 recommendations, the incident photon fluence could be defined as about $4 photons/(0.01mm)^2{\cdot}{\mu}Gy$ within $10{\mu}m$ pin-hole area, and about $50photons/(0.03mm)^2{\cdot}{\mu}Gy$ within $30{\mu}m$ pin-hole area, and about $698photons/(0.1mm)^2{\cdot}{\mu}Gy$ within $100{\mu}m$ pin-hole area. Consequently, with the previously setup of the incident fluence, the measuring of actual photon counting efficiency by observing the output waveform of the photon counting sensor material was considered possible.

Measuring displacements of a railroad bridge using DIC and accelerometers

  • Hoag, Adam;Hoult, Neil A.;Take, W. Andy;Moreu, Fernando;Le, Hoat;Tolikonda, Vamsi
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.225-236
    • /
    • 2017
  • Railroad bridges in North America are an integral but aging part of the railroad network and are typically only monitored using visual inspections. When quantitative information is required for assessment, railroads often monitor bridges using accelerometers. However without a sensor to directly measure displacements, it is difficult to interpret these results as they relate to bridge performance. Digital Image Correlation (DIC) is a non-contact sensor technology capable of directly measuring the displacement of any visible bridge component. In this research, a railroad bridge was monitored under load using DIC and accelerometers. DIC measurements are directly compared to serviceability limits and it is observed that the bridge is compliant. The accelerometer data is also used to calculate displacements which are compared to the DIC measurements to assess the accuracy of the accelerometer measurements. These measurements compared well for zero-mean lateral data, providing measurement redundancy and validation. The lateral displacements from both the accelerometers and DIC at the supports were then used to determine the source of lateral displacements within the support system.

Comparison of the Detection Efficiency $a-Se_{1-x}As_x$ in X-ray Detection Sensor of $Gd_2O_2S(Eu^{2+})/a$-Se Structure ($Gd_2O_2S(Eu^{2+} )/a$-Se$ 구조의 X선 검출 센서에서 $a-Se_{1-x}As_x$의 검출효율 비교)

  • Kang, Sang-Sik;Park, Ji-Koon;Lee, Dong-Gil;Mun, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.436-439
    • /
    • 2002
  • Recently, It has performed that the basic research of the photoconductive material and the development and application of the digital radiograph detector which is divided into the direct and indirect method. The objective of this study investigate the effect of the electric characteristic about changing the composition of Arsenic in hybrid detector system for compensating a defect of conventional. We fabricated samples using the amorphous Selenium and Arsenic alloy with various concentrations of the Arsenic{seven step 0.1%, 0.3%, 0.5%, 1%, 1.5%, 3%, 5%). And using EFIRON optical adhesives the formed multi-layer$(Gd_{2}O_{2}S(Eu^{2+}))$ composed phosphor layer. X-ray and light sensitivity was measured to study x-ray response characteritics. As results, highest value was measured as output net charge and SNR were $315.7pC/cm^2/mR$ and 99.4 at 0.3%As doping ratio.

  • PDF

Color Interpolation Algorithm for Pixel Resolution Modus of Image Sensor (영상센서의 출력 해상도 모드를 고려한 색상 보간 알고리즘)

  • Kim, Bu-Gong;Kim, Moon-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.129-138
    • /
    • 2014
  • Various interpolations for digital imaging devices with a single image sensor have proposed. However, conventional methods did not consider the resolution modus of image sensor using periodic sampling. Therefore, the resulting images have problems such as quality degradation and color artifacts(color moire, zipper). In this paper, we propose a color interpolation algorithm for pixel resolution modus of image sensor. The proposed algorithm consisted of an initial step to compensate edge prediction effectively and refinement step using minimum directions for pixel resolution modus. To analyze a result of the proposed algorithm with conventional methods, we evaluated subjectively using images quality comparison and objectively using PSNR(Peak Signal to Noise Ratio). Experimental results showed that the proposed algorithm was more successful in eliminating the color artifacts than conventional methods judged by both objective and subjective criteria.