• Title/Summary/Keyword: Digital ID

Search Result 212, Processing Time 0.028 seconds

A Study of RF Watermark Backward Compatibility under Various Channel Environments (다양한 채널환경 하에서의 RF 워터마크 역호환성 연구)

  • Kim, Jeong-Chang;Park, Sung-Ik;Choi, Dae-Won;Lim, Hyoung-Soo;Kim, Heung-Mook
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.8
    • /
    • pp.99-107
    • /
    • 2010
  • In a single frequency network (SFN) for Advanced Television Systems Committee (ATSC) terrestrial digital television (DTV) system, the interferences induced by the multiple transmitters and/or repeaters using the same frequency are inevitable. Since the presence of interferences results in performance degradation of the SFN, it is crucial to manipulate the interferences by adjusting the transmit power and timing of each transmitter and repeater. In the ATSC terrestrial DTV system, in order to facilitate the interference manipulation process, a transmitter identification (TxID) signal which is uniquely embedded in the signal to be transmitted from each transmitter and repeater is recommended. Even though the injection level of the TxID signal is much lower than the DTV signal, the TxID signal injection infects the DTV signal. Hence, the effect of the TxID signal on the DTV signal must be investigated before deployment. In this paper, the effect of the TxID signal on the performance of legacy DTV receivers under additive white Gaussian noise and multipath channel environments is investigated not only with computer simulation but also with laboratory and field tests. The test results show that the average threshold of visibility degradation of the legacy DTV receivers due to the TxID signal injection is less than 0.2 dB at the TxID injection level of -30 dB.

Secure One-Time Password Authentication in Mobile Environments (모바일 환경에서 안전한 일회용 패스워드 인증)

  • Kim, Dong-Ryool
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.423-430
    • /
    • 2013
  • With the active Internet e-commerce and the financial sector, mutual authentication between users and service providers has become very important. Because ID- and password-based authentication is of low security, one-time password authentication methods are widely used. The existing one-time password authentication scheme of S/Key authentication method is fraught with a number of issues in addition to plain text transmission, and the method of Kim Gong-ki et al. does not offer suggestions for session key generation and distribution method. Proposed in this paper is a protocol that solves these problems.

Kerberos Authentication Deployment Policy of US in Big data Environment (빅데이터 환경에서 미국 커버로스 인증 적용 정책)

  • Hong, Jinkeun
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.435-441
    • /
    • 2013
  • This paper review about kerberos security authentication scheme and policy for big data service. It analyzed problem for security technology based on Hadoop framework in big data service environment. Also when it consider applying problem of kerberos security authentication system, it analyzed deployment policy in center of main contents, which is occurred in commercial business. About the related applied Kerberos policy in US, it is researched about application such as cross platform interoperability support, automated Kerberos set up, integration issue, OPT authentication, SSO, ID, and so on.

Research on key management for supervisory control and data acquisition system (원격 감시 제어시스템에서 키 관리 방안 연구)

  • Lee, Keonjik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.4
    • /
    • pp.29-42
    • /
    • 2020
  • SCADA (Supervisory Control and Data Acquisition) systems for remote monitoring, data acquisition and control are applied to major industrial infrastructures including power, water and railroad. Recently, there are many researches on key management scheme for secure communication due to change to the open network environment. These systems are located at far distances and are connected to the main control center through various types of communication methods. Due to the nature of these systems, they are becoming the significant targets of cyber attack. We propose an efficient key management scheme which is established on ID-based cryptosystem without an expensive computation on MTU (Master Terminal Unit), Sub-MTU, and RTU (Remote Terminal Unit). The proposed method is secure and effective in key management among multiple legitimate devices.

Implementation of a very small 13.56[MHz] RFID Reader ensuring machine ID recognition in a noise space within 3Cm (3Cm 이내의 잡음 공간 속 기계 ID 인식을 보장하는 초소형 13.56[MHz] RFID Reader의 구현)

  • Park, Seung-Chang;Kim, Dae-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.10 s.352
    • /
    • pp.27-34
    • /
    • 2006
  • This paper has implemented a very small($1.4{\times}2.8[Cm^2]$) 13.56[MHz] RFID reader ensuring machine ID recognition correctly in a noise space of Tag-to-Reader within 3Cm. For operation of the RFID system, at first, this paper has designed the loop antenna of a reader and the fading model of back-scattering on microwave propagation following to 13.56[MHz] RFID Air Interface ISO/IEC specification. Secondly, this paper has proposed the automatically path selected RF switching circuit and the firmware operation relationship by measuring and analyzing the very small RFID RF issues. Finally, as a very small reader main body, this paper has shown the DSP board and software functions made for extraction of $1{\sim}2$ machine ID information and error prevention simultaneously with carrying of 13.56[MHz] RFID signals that the international standard specification ISO/IEC 18000-3 defined.

Performance of Indoor Positioning using Visible Light Communication System (가시광 통신을 이용한 실내 사용자 단말 탐지 시스템)

  • Park, Young-Sik;Hwang, Yu-Min;Song, Yu-Chan;Kim, Jin-Young
    • Journal of Digital Contents Society
    • /
    • v.15 no.1
    • /
    • pp.129-136
    • /
    • 2014
  • Wi-Fi fingerprinting system is a very popular positioning method used in indoor spaces. The system depends on Wi-Fi Received Signal Strength (RSS) from Access Points (APs). However, the Wi-Fi RSS is changeable by multipath fading effect and interference due to walls, obstacles and people. Therefore, the Wi-Fi fingerprinting system produces low position accuracy. Also, Wi-Fi signals pass through walls. For this reason, the existing system cannot distinguish users' floor. To solve these problems, this paper proposes a LED fingerprinting system for accurate indoor positioning. The proposed system uses a received optical power from LEDs and LED-Identification (LED-ID) instead of the Wi-Fi RSS. In training phase, we record LED fingerprints in database at each place. In serving phase, we adopt a K-Nearest Neighbor (K-NN) algorithm for comparing existing data and new received data of users. We show that our technique performs in terms of CDF by computer simulation results. From simulation results, the proposed system shows that a positioning accuracy is improved by 8.6 % on average.

DB뱅크 - 과학기술분야 '세계최대'의 정보원

  • Kim, Hwi-Chul
    • Digital Contents
    • /
    • no.7 s.50
    • /
    • pp.42-47
    • /
    • 1997
  • 국내에서 STN을 이용하려면 산업기술정보원에서 ID와 패스워드를 부여받아야 하고 이용요금은 각 데이터베이스마다 검색어 사용 회수와 접속시간 및 출력건수에 따라 다른데 CA같은 경우에는 시간당 약 150$정도가 된다. 가입비는 25$이다.

  • PDF

ePosition Identification linked Model Based on ENC (전자해도 기반의 위치식별 ID 연계 모델)

  • Seo, Gi-Yeol;Lee, Sang-Ji;O, Se-Ung;Seo, Sang-Hyeon;Park, Gye-Gak
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.201-205
    • /
    • 2007
  • This paper proposes a link model that can provide the spacial position along the surface of the earth as an information or data using ePosition ID through the Internet. Moreover, to support the information service of maritime position, it needs the ENC linked technique based on S-57 that is an IHO transfer standard for digital hydrographic data. Therefore, it designs the linked model for applying and utilizing the ePosition technology with ENC data, as well as supplementing the base technology in applying them to marine related fields. As a study method, this paper first analyses ENC data model and structure, and converses for processing of ENC file to ePosition data. Finally, it derives the interconnection method with ePosition database and shows the ePosition service application based on the linked ENC data and its validity.

  • PDF

Development of a Prototype for the Digitalized Nuclear Power Plant's Main Control Room (원자력발전소 디지털형 주제어실 모형 개발)

  • Jung, Yeon-Sub;Cho, Sung-Jae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.145-152
    • /
    • 2009
  • Domestic Kori-1 MCR was partially modified in 2007 and will be renovated entirely in 2013. Digital devices partially replacing original analog devices have been introduced and standard alone computer systems such as SPDS have been integrated into the plant computer. Upgrading KSNP's MCR based on the ditalization is planned for 2015. However, the site engineers and operators are reluctant to the advanced systems. Therefore, a prototype for the KSNP's advanced MCR has been developed to increase the acceptance level of the operators and field engineers and also, to evaluate user interfaces and I&C architecture. For enhancing support of the operators' work, a P&ID based display system composed of multi-layers, which are linked through a context sensitive menu each other, has been adopted. The $1^{st}$ layer displays a simplified P&ID, the $2^{nd}$ layer control related diagrams such as controllers and logic diagrams, the $3^{rd}$ layer trends, etc. The end point view of MCR for KSNP is also suggested considering reliability and operability of the digital systems. Additionally, modernization strategies over the overhaul periods, that do not have much impact on operation and configuration efforts are suggested.

  • PDF