• Title/Summary/Keyword: Digital Data Transmission

Search Result 679, Processing Time 0.023 seconds

A Design of Multi-Channel Biotelemetry for ECG Encoding and Transmission Over the Public Telephone Line (공중 전화회선용 다중 채널 ECG데이터 원격 측정시스템 설계)

  • Gye, Sin-Ung;Jang, Won-Seok;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 1986
  • In this paper, we described the ECG telemetry system via the Public Telephone Line. The system consist of a signal acquisition and measurement section, a signal processing section, and a signal transmission section. It used 8 bits microprocessor. The transmission section is composed of 3 ch. analog modulators and 1 ct. digital modem. Especially, using the digital modem, signal is transmitted with about 50n data reduction ratio by the TP (Turning Point) algorithm. The acoustic coupler or inductive coil for linking the public telephone line are used. The speed of the digital modem is 300 baud rate. The MCBS (Multi Channel Biotelemetry System) is tested and evaluated through the experiment.

  • PDF

Initial Timing Acquisition for Binary Phase-Shift Keying Direct Sequence Ultra-wideband Transmission

  • Kang, Kyu-Min;Choi, Sang-Sung
    • ETRI Journal
    • /
    • v.30 no.4
    • /
    • pp.495-505
    • /
    • 2008
  • This paper presents a parallel processing searcher structure for the initial synchronization of a direct sequence ultra-wideband (DS-UWB) system, which is suitable for the digital implementation of baseband functionalities with a 1.32 Gsample/s chip rate analog-to-digital converter. An initial timing acquisition algorithm and a data demodulation method are also studied. The proposed searcher effectively acquires initial symbol and frame timing during the preamble transmission period. A hardware efficient receiver structure using 24 parallel digital correlators for binary phase-shift keying DS-UWB transmission is presented. The proposed correlator structure operating at 55 MHz is shared for correlation operations in a searcher, a channel estimator, and the demodulator of a RAKE receiver. We also present a pseudo-random noise sequence generated with a primitive polynomial, $1+x^2+x^5$, for packet detection, automatic gain control, and initial timing acquisition. Simulation results show that the performance of the proposed parallel processing searcher employing the presented pseudo-random noise sequence outperforms that employing a preamble sequence in the IEEE 802.15.3a DS-UWB proposal.

  • PDF

Design Issues of Digital Display Interface

  • Jeong, Deog-Kyoon;Oh, Do-Hwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.993-996
    • /
    • 2007
  • Depending on applications where transmission bandwidth, wire distance, power consumption and EMI environments vary, design trade-offs must be made to optimize the display interface. After introducing the digital display interface architecture, topics such as cost, EMI, signal integrity, scalability and content protection are discussed with available techniques. Implementation issues are discussed regarding their cost and design complexity. Existing standards are reviewed and comparison on their strengths and shortcomings are discussed.

  • PDF

Analysis of Data Transmission Rate and Power Consumption in Zigbee Based Electrocardiography (지그비 기반 심전계의 데이터 전송률과 소비 전력 분석)

  • Kim, Nam-Jin;Hong, Joo-Hyun;Lee, Tae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.96-104
    • /
    • 2006
  • In this study, data transmission ratio and power consumption issues of Zigbee based sensor module and personal digital assistant(PDA) were addressed to develop ECG telemetry device. PDA processes the data transmitted through serial port using non-blocking method. The transmission rate was dependent on the packet structure. It was 300 ECG samples/sec, when each packet was composed of 2 ECG data and 3-axial acceleration vector. Using two AAA batteries in series, operating time of the wireless sensor module was above 28 hours in average. Power consumption of PDA was dependent on screen ON/OFF condition and serial port usage. In this application, operating time of PDA was 5 hours in average. In conclusion, there was no problem in the power consumption of wireless sensor module and transmission rate, when the developed device was used as 24 hour Holter device. But, PDA has the problem of power consumption, which should be solved.

  • PDF

Design of MAGLEV Information Transmission System by Radio Inductive Loop (유도무선루프에 의한 자기부상열차 정보전송 시스템의 설계)

  • An, Sang-Gwon;Park, Seok-Ha;Park, Jeong-Su;Kim, Jong-Beom;Kim, Yang-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.1
    • /
    • pp.42-47
    • /
    • 1999
  • This paper presents the information transmission between on-board and ground-site in MAGLEV. considering safety and high speed operation and density operation, information transmission between them is necessary. Therefore it is necessary for transmission system to ensure high speed transmission, low error rate, massive information, and reliability of information. To provide above conditions, 1.1km signal line assembly was constructed and Frequency Shift Keying(FSK) modulation and Open System Interconnection(OSI) based high-level data link control(HDLC) protocol are applied. To modulate digital signal for transmission from ground-site to on-board, carrier frequency of 70kHz is used and 90khz is used for transmission from on-board to ground-site. Transmission speed is 2400bps for consideration of train speed, quantity of information, and data error rate. And this paper introduces information monitoring considering user interface and presents the method for an effective data transmission in MAGLEV which is now being tested and intends to provide for an intelligent train operation system in future.

  • PDF

Data Transmission Method using Broadcasting in Bluetooth Low Energy Environment (저전력 블루투스 환경에서 브로드캐스팅을 이용한 데이터전송 방법)

  • Jang, Rae-Young;Lee, Jae-Ung;Jung, Sung-Jae;Soh, Woo-Young
    • Journal of Digital Contents Society
    • /
    • v.19 no.5
    • /
    • pp.963-969
    • /
    • 2018
  • Wi-Fi and Bluetooth technologies are perhaps the most prominent examples of wireless communication technologies used in the Internet of Things (IoT) environment. Compared to widely used Wi-Fi, Bluetooth technology has some flaws including 1:1 connection (one-way) between Master and Slave, slow transmission, and limited connection range; Bluetooth is mainly used for connecting audio devices. Since the release of Bluetooth Low Energy (BLE), some of the flaws of Bluetooth technology have been improved but it still failed to become a competitive alternative of Wi-Fi. This paper presents a method of data transmission through broadcasting in BLE and demonstrates its performance, one-to-many data transfer result. The Connection-Free Data Transmission proposed in this paper will hopefully be utilized in special circumstances requiring 1:N data transmission or disaster security network.

An Implementation of TPEG Transmission and Reception Systems Based on Digital Radio Mondiale (DRM 기반 TPEG 송.수신 시스템 구현)

  • Kwon, Ki-Won;Park, Kyung-Won;Jeon, Won-Gi;Choi, Young-Keon;Chang, Tae-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.125-128
    • /
    • 2008
  • In this paper, the Transport Protocol Experts Group(TPEG) transmission and reception system based on Digital Radio Mondiale(DRM) is implemented for traffic information services. DRM stands for the European radio broadcasting standard to bring AM radio into digital radio, designed to work at frequencies below 30MHz. DRM can offer various data services such as text messages and a slide show service as well as audio services. In spite of low datarate, the TPEG system on DRM has an advantage that the traffic information service system for whole country can be established because DRM can offer wider service ranges than terrestrial-digital multimedia broadcasting(T-DMB) and simply archive a single frequency network.

  • PDF

Design of Lightweight CAD Files with Dimensional Verification Capability for Web-Based Collaboration (웹기반 협업을 위한 치수검증이 가능한 경량캐드파일 설계)

  • Song In-Ho;Chung Sung-Chong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.5 s.248
    • /
    • pp.488-495
    • /
    • 2006
  • The demand for the use of 3D CAD data over the Internet environment has been increased. However, transmission of 3D CAD data has delayed the communication effectiveness because of the CAD data size. Lightweight CAD file design methodology is required for rapid transmission in the distributed environment. In this paper, to derive lightweight CAD files from commercial CAD systems, a file translation system producing a native file is constructed first by using the InterOp and API of the ACIS kernel. Using the B-rep model and mesh data extracted from the native file, the lightweight CAD file with topological information is constructed as a binary file. Since the lightweight CAD file retains topological information, it is applied to the dimensional verification, digital mock-ups and visualization of CAD files. Effectiveness of the proposed lightweight CAD file is confirmed through various case studies.

Development of 32-Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 32채널 영상획득장치 개발)

  • 양근호;유병국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.110-113
    • /
    • 2003
  • In this paper, the multi-channel high speed data acquisition system is implemented. This high speed signal processing system for 3-D image display is applicable to the manipulation of a medical image processing, multimedia data and various fields of digital image processing. In order to convert the analog signal into digital one, A/D conversion circuit is designed. PCI interface method is designed and implemented, which is capable of transmission a large amount of data to computer. In order to, especially, channel extendibility of images acquisition, bus communication method is selected. By using this bus method, we can interface each module effectively. In this paper, 32-channel A/D conversion and PCI interface system for 3-dimensional and real-time display of the retina image is developed. The 32-channel image acquisition system and high speed data transmission system developed in this paper is applicable to not only medical image processing as 3-D representation of retina image but also various fields of industrial image processing in which the multi-point realtime image acquisition system is needed.

  • PDF

A Study on Description of IEC 61850 based Substation Topology for Implementing the Engineering Tool of Digital Substation (디지털변전소 엔지니어링 툴 구현을 위한 IEC 61850 국제규격 기반의 변전소 토폴로지 표현에 관한 연구)

  • Lee, Nam-Ho;An, Yong Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.23-32
    • /
    • 2015
  • In order to complete engineering works of the digital substation, Both Data transmission among a variety of IEDs and HMIs, and single line diagram of the substation might be done based on XML documents published in IEC 61850 international standards. This kind of XML based engineering process for the digital substation must be implemented not by manual written work but by the engineering tool using a computer. But most of the engineering tools do not support system based engineering works such as single line diagram of the substation but have only function to set IEDs as single device unit. Accordingly, this paper presents a new design method of the system based engineering description applicable to real IEC 61850 based substation through analyzing the current international standard and its sampled engineering file, and shows implementation of the engineering tool of the digital substation with the result of this study.