• Title/Summary/Keyword: Digester with tray motion mixer

Search Result 2, Processing Time 0.021 seconds

Measurement of Flow Characteristics of Digester Installed Tray Motioned Mixer by Using Radiotracer (방사성추적자를 이용한 수직교반형 소화조의 유동 특성 측정)

  • Moon, Jinho;Park, Jang Guen;Kang, Munhu;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.131-135
    • /
    • 2015
  • The flow characteristics of fluid were measured using radioactive tracer in pilot scale digester with tray motion mixer. In consideration of the detection volume of the detector and the size of the digester, 20 detectors were installed in the digester. The radioactive tracer eluted 8 mCi of $^{68}Ga$ from $^{68}Ge/^{68}Ga$ generator was injected into the digester bottom. After radiotracer injection, the flow pattern was measured on the basis of the initial movement of the tracer until its diffusion completely. Most of tracer moved to the wall along the bottom of the digester, and then rose along the wall. The other tracer moved up along the mixer, and then moved to the wall direction along the surface.

A Study on the Effect of Energy Saving with Newly Implemented Vertical Circulating Tray Mixer in Anaerobic digester (혐기성 소화조의 에너지 효율 향상을 위한 수직 왕복형 교반기 적용에 관한 연구)

  • Joo, Yoon-Sik;Son, Guntae;Bae, Youngjun;Park, Jungsoo;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Relatively low efficiency in anaerobic digestion process is mainly caused by unproper mixing method. In this study, tray motion type agitator was applied in actual anaerobic digestion tank in order to improve the digestion efficiency, equalize the flow velocity distribution and energy saving. The impeller of tray motion type agitator was reciprocated vertically. Gas lift type agitator and tray motion type agitator appears almost same mixing efficiency include digestion rates. However, tray motion type agitator have shown that lower energy consumption compared to the conventional gas lift type agitator. Implementation of tray motion type agitator in the anaerobic digestion tanks contributed to the stabilization of mixing environment, efficiency and energy efficiency of the tank.