• Title/Summary/Keyword: Digested sludge

Search Result 77, Processing Time 0.02 seconds

Effect of Wet Milling on Scum Generation and Solubilization in Batch Ozone Reaction Using Digested Sludge (소화슬러지를 이용한 회분식 오존반응 시 습식분쇄가 스컴 생성과 가용화에 미치는 영향)

  • Hong, Seong-Min;Lee, Dong-Hoon;Kim, Choong-Gon;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.13-18
    • /
    • 2019
  • Sewage sludge treatment is increasing every year due to improvement of living and urbanization. However, interest in anaerobic digestion which is one of the recycling technology. There is anaerobic digestion of increasing due to limitations of ocean dumping and final disposal. But, the limit of anaerobic digestion efficiency due to the advanced treatment of sewage has been limited, and studies for solubilization technology have been actively conducted. Therefore, in this study, we aimed to investigate the variation of generation of scum and the solubilization efficiency in the application of pre-treatment of ozone reaction and the change of properties of digested sludge with wet milling. There are results of VS/TS increased by 4.4% and $SCOD_{cr}/TCOD_{cr}$ increased by 9.4% by wet milling alone. In addition, the increase of the specific surface area due to which the reduction of the particle size of the solid content of the sludge in the ozone reaction caused by wet milling decreased the generation rate of scum at 14.3% and increased VS/TS at 2.1%, compared with the ozone reaction alone. From these results, it is expected that the application of wet milling can be increased the contact efficiency with solids in the sludge during ozone reaction with suppress scum and increase the efficiency of the subsequent process in anaerobic digestion.

Contemporary Organic Contamination Levels in Digested Sewage Sludge from Treatment Plants in Korea : (3) Organophosphorus Insecticides (우리나라 하수 및 폐수 처리 슬러지의 유기인계 살충제의 함량)

  • Hong Gi-Hoon;Lee Kang-Young;Chung Chang-Soo;Lee Hyun-Kyung
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.229-236
    • /
    • 2006
  • Organophosphorus pesticides (OPPs) contents in the sewage sludge derived from the residential and industrial areas were determined in order to characterize contemporary organic contamination levels as a part of the ongoing development of the environmentally sound sewage sludge management strategy in Korea. OPPs were extracted from freeze-dried sludges in a ultrasonic extractor. The extracts were cleaned-up by florisil column and subsequently fed into gas chromatograph/nitrogen phosphorus detector (GC/NPD) for determining OPP contents. Diazinon, dimethoate, disulfoton, EPN, malathion, methyl parathion, parathion, phorate and sulfotep were present in the appreciable amount in the domestic sewage sludges. The sum of the 9 OPPs in the sewage sludge varied from 534.8 to 15552.1 ${\mu}g/kg$, dry wt..

Anaerobic Degradation of Petroleum Hydrocarbons in Soil by Application of a Digestion Sludge (소화슬러지를 이용한 토양 내 석유계 탄화수소의 혐기성 분해)

  • Lee, Tae-Ho;Byun, Im-Gyu;Park, Jeung-Jin;Park, Hyun-Chul;Park, Tae-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.938-943
    • /
    • 2007
  • Anaerobic degradation of petroleum hydrocarbons in a soil artificially contaminated with 10,000 mg/kg soil of diesel fuel was tested by adding an anaerobic sludge taken from a sludge digestion tank. Treatments of soil(50 g) with 15 mL/kg soil and 30 mL/kg soil of the digestion sludge(2,000 mg/L of vss(volatile suspended solids)) showed 37.2% and 58.0% of total petroleum hydrocarbons(TPH) removal during 90 days incubation, respectively. In evaluation of several anaerobic conditions including nitrate reducing, sulfate reducing, methanogenic, and mixed electron accepters condition, treatments with the digested sludge showed significant degradation of diesel fuel under all anaerobic conditions compare to a control treatment of soil without the sludge and a treatment of autoclaved soil treatment with autoclaved digestion sludge. The rate of diesel fuel degradation was the highest in the treatment with the sludge and mixed electron accepters (75% removal of TPH) for 120 days incubation followed in order by sulfate reducing, nitrate reducing, methanogenic condition as 67%, 53%, 43%, respectively. However, the removal rate of non-biodegradable isoprenoid was the highest in the sulfate reducing condition. These results suggest that anaerobic degradation of diesel fuel in soil with digested sludge is effective for practical remediation of soil contaminated with petroleum hydrocarbons.

Comparison of the Dewatering Characteristic Using Specific Resistance and Capillary Suction Time of Digested Sewage Sludge by Ultrasonic Treatment (초음파로 처리된 소화슬러지의 비저항계수 (SRF)와 모세관흡입시간(CST)을 이용한 탈수특성 비교)

  • Na, Seung-Min;Park, Ji-Ho;Kim, Young-Uk;Khim, Jee-Hyeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.287-290
    • /
    • 2007
  • We investigated the effect of ultrasound on the dewaterability of sewage sludge. Because, dewatering and disposal of waste sludge is a major economical factor in the operation of wastewater treatment plants. Capillary Suction Time(CST) and Specific Resistance to Filtration (SRF) were used to evaluate the sludge dewatering behaviors. From the results of the experiment, it was found that ultrasonic treatment can improve the dewaterability. We discovered that CST and SRF were highly related, according to the correlation coefficient($R^{2}$).

  • PDF

A study of struvite control using CO2 in sewage treatment process (하수처리공정에서 이산화탄소를 이용한 스트러바이트 제어에 관한 연구)

  • Han, Keumseok;Hong, Seongho;Choi, Youngjune
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.261-268
    • /
    • 2018
  • Sludge transporting pipes in wastewater treatment plant are easy to be clogged with struvite when the digested sludge and dehydrated filtrate are transported through the pipes, which lowers the efficiency of sludge treatment system in a WWTP. pH is one of the most important factors in struvite formation, and carbon dioxide separated from biogas can be used to control pH and struvite formation. By controlling pH, the amount of dehydrating agent can be reduced by about 10%, which saves the budget for facility maintenance. As $CO_2$ is reused and dehydrating chemicals are saved, the approach can contribute to global warming gas reduction.

A Study on the Conditioning with Polymer and the Particle Size Distribution of Intermittent Aerobic Digestion Sludge (간헐포기 소화 슬러지의 고분자 응집제에 의한 개량과 입도 분포 변화에 관한 연구)

  • Kim, Hee-Jun;Kim, Seong-Hong;Choi, Jae-Seong
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • Synthetic organic polyelectrolytes can be used to condition sludges to enhance their dewaterability. Intermittent aerobic digestion is an useful digestion technology and has many advantages like neutral pH, low installation cost and easiness to operation. The objectives of this study were to investigate the dewaterability of intemittent aerobic digestion sludge and to find the relationship between dewaterability and particle size distribution change under the conditioning of intermittent aerobic digestion sludge by cationic polyelectrolyte. Digested sludge from intermittent aerobic digestion was used and cationic polyacrylamide polymer was added as a conditioner. CST(capillary suction time), TTF(time-to-filtration) were tested as a dewaterability index and the number of particle distribution was analyzed using particle size analyzer. The results indicate that cationic polyelectrolytes is useful to enhance dewaterability of intermittent aerobic digestion sludge. Mean particle diameter was increased as polymer dosage increased and its value was reached up to 100 mm on the condition of optimal cationic polymer dosage. CST and TTF are well correlated with mean particle diameter when the weighting order is 1.7. By the optimal conditioning with cationic polymer, particles in the filtrate are also reduced significantly and this means that conditioning is helpful to main stream by reducing SS loading from return flow.

Characteristics for Co-digestion of Food Waste and Night Soil using BMP Test (BMP실험을 이용한 음식물폐기물 및 분뇨의 병합소화 특성)

  • Cho, Jinkyu;Kim, Hyungjin;Oh, Daemin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.13-18
    • /
    • 2014
  • BMP test was carried out to evaluate the characteristics for co-digestion of night soil and food waste. 6 types of sludge were tested in 30 days which were raw, excess, digested, night soil/septic tank (1:1), food waste (food : dilution water = 1:1), and mixed sludge. Bio gas was produced actively after 2 days, and continued in 2 weeks. Gas generation amount was decreased rapidly after considerable space of time. Especially maximum productivity of gas was shown in 7~8 days. The ultimate methane yields of raw, excess, digested, night soil/septic tank, food waste, and mixed sludge were 64.63, 67.49, 66.45, 72.44, 107.85, and 46.71 mL $CH_4/g$ VS respectively from Modified Gompertz model. The lag growth phase time and maximum specific methane production rate of mixed sludge were 1.88 day and 80.4 mL/day respectively. The methane potential of mixed sludge was higher than individual sludge. So high methane potential was expected by controlling mixing ratio of food waste. Besides stable operation of digestion tank and the solution of oligotrophic problem were possible.

Efficient Dewatering of the Sewage Sludge by Electrodewatering System (전기탈수방법에 의한 하수 슬러지 탈수 특성)

  • Park, Chan-Jung;Lee, Jung-Eun;Ahn, Young-Chull;Shin, Hee-Soo;Lee, Jae-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.526-531
    • /
    • 2000
  • Application of electrodewatering (EDW) to mechanical dewatering system was studied to decrease water content in the sludge generated from waste water treatment process. Experiments realized the reduction of water content in the sewage sludge. EDW enhancing the conventional filtration by an electric field is an emerging technology with the potential to improve dewatering. In this study, a piston filter press was constructed, the digested sludges were dewatered by EDW under conditions of DC electric field and constant pressure in the piston filter press. Constant electric field from $0{\sim}120\;V/cm$ and constant pressure $98.1{\sim}392.4\;kPa$ were used. The results showed that as electric field was increased the dewatering rates increased and as pressure was increased the dewatering rates decreased. Also as polymer was added the dewatering rates increased. This experiments produced final sludge cake with water content of 60 wt% using EDW, compared with 80 wt% using pressure filtration alone.

  • PDF

Temperature Effect of the UASB Process for Treatment of Organic Waste (상향류식 혐기성 입상슬러지 공법의 유기폐수 처리 효율에 미치는 온도의 영향)

  • Park, Chul Hwi;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.45-54
    • /
    • 1996
  • Effects of temperature on the efficiency of the Upflow Anaerobic Sludge Blanket(UASB) process for treatment of wastewater from a starch and related products manufacturing industry were investigated using laboratory scale reactors equipped with two types of Gas-Solid Separator(GSS). Both fresh digested sludge and granular sludge stored nearly for one year at room temperature were good as a seeding material. The reactors seeded with aged granular sludge showed slow start-up, however, lowered activity at the initial period was recovered gradually. The GSS with an inner cylinder was proved to be effective in liquid-solid separation compared to the conventional type. Although the rate of organic removal and gas production per unit volatile suspended solids in the reactor reduced significantly as the temperature varied from 35 to $20^{\circ}C$, possibility of operation at low temperatures was shown as a result of gradual buildup of volatile suspended solids in the bed. Stable operation with a reduced efficiency was possible at a COD loading of $5-8kg/m^3/day$ at a temperature as low as $20^{\circ}C$.

  • PDF

Coupling Equation of Specific Resistance to Filtration(SRF) and Capillary Suction Time(CST) of Digested Sewage Sludge (소화슬러지의 비저항계수(SRF)와 모세관흡입시간(CST)의 상호관계식 유도 및 비교)

  • Khim, Jee-Hyeong;Na, Seung-Min;Park, Ji-Ho;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.874-880
    • /
    • 2007
  • Capillary Suction Time(CST) and Specific Resistance to Filtration(SRF) were commonly used to evaluate the sludge dewatering behaviors. A coupled equation was developed through the mathematical theory which represented both CST and SRF as the physical filterability of the ultrasonically treated sludge. The model for coupling CST and SRF includes both equipment variables and variables related to sludge characteristics, and verified with the results from experiments. The results of the theoretical and experimental study showed that a good correlation relationship among dewaterability indices.

  • PDF