The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.
Journal of Korean Society for Atmospheric Environment
/
v.29
no.1
/
pp.56-63
/
2013
This study was aimed at developing and evaluating a diffusive sampling method using a barium hydroxide solution as an absorbent for measuring carbon dioxide ($CO_2$) in ambient air. The collected $CO_2$ concentration was calculated by the change of conductivity resulted in the reaction of $CO_3{^{2-}}$ and $Ba^{2+}$ in aqueous solution. The sampling rate for the diffusive sampler was determined 0.218 mL/min, as obtained from the slope of the linear correlation between the $CO_2$ mass collected by the diffusive sampler and the time-weighted $CO_2$ concentration with the active sampling method. The unexposed blank sampler sealed in aluminium foil-polyethylene laminated packets has remained stable during at least one-month storage period. A good correlation was observed between the diffusive sampler and active sampler with a coefficient of determination of 0.956. This diffusive sampler would be suitable for the indoor $CO_2$ concentration monitoring.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.4
no.2
/
pp.208-223
/
1994
The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.
Passive samplers have been used for many years for the sampling of organic vapors in work environment atmospheres. Currently, all passive samplers used in domestic occupational monitoring are foreign products. This study was performed to evaluate variable parameters for the development of passive organic samplers, which include the geometry of the device and diffusive length for the sampler design. Four prototype diffusive lengths; A-1(4.5 mm), A-2(7.0 mm), A-3(9.5 mm), A-4(12.0 mm) were tested for adsorption performances to a chemical mixture (benzene, toluene, trichloroethylene, and n-hexane) according to the US-OSHA's evaluation protocol. A dynamic vapor exposure chamber developed and verified by related research was used for this study. The results of study are as follows. The results in terms of sampling rate and recommended sampling time test indicate that the most suitable model was A-3 (9.5 mm diffusive lengths on both sides) for passive sampler design in time weighted average (TWA) assessment. Sampling rates of this A-3 model were 45.8, 41.5, 41.4, and 40.3 ml/min for benzene, toluene, trichloroethylene, and n-hexane, respectively. The A-3 models were tested on reverse diffusion and conditions of low humidity air (35% RH) and low concentrations (0.2 times of TLV). These conditions had no affect on the diffusion capacity of samplers. In conclusion, the most suitable design parameters of passive sampler are: 1) Geometry and structure - 25 mm diameter and 490 $mm^2$ cross sectional area of diffusion face with cylindrical form of two-sided opposite diffusion direction; 2) Diffusive length - 9.5 mm in both faces; 3) Amount of adsorbent - 300 mg of coconut shell charcoal; 4) Wind screen - using nylon net filters (11 ${\mu}m$ pore size).
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.15
no.3
/
pp.261-269
/
2005
To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.
Kim, Hyo-Cherl;Paik, Nam-Won;Kim, Kyoung-Ran;Kim, Kyoung-Su;Lee, Kyoung-Suk;Cho, Kyung-Ah
Proceedings of the Korean Environmental Health Society Conference
/
2005.06a
/
pp.371-372
/
2005
Active sampler has been widely used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. The result of these tests that indicated that passive sampler can be used instead of active sampler in ETS, because coefficient of determination was 0.9292 between active and passive sampling in smoking area
Journal of Korean Society for Atmospheric Environment
/
v.21
no.6
/
pp.593-603
/
2005
Passive sampler using 4-amino-3-hydrazino-5-mercapto-1, 2, 4-triazole (AHMT) was developed to determine formaldehyde in indoor environment. The chromatography paper cleaned by $3\%$ hydrogen peroxide solution was experimently determined as a optimum absorbtion filter for the collection of formaldehyde. The passive sampler with a broad cross-sectional area and a short diffusion length was quite good in sensitivity. The passive sampler and the active sampling method with an impinger were strongly correlated with a correlation coefficient of 0.9848. The limits of detection and quantification of the passive sampler for the measurement of formaldehyde in the indoor environment were 7.5 and 10.2 ppb, respectively. Temperature ($19\∼28^{circ}C$) and relative humidity ($30\∼90\%$) had slight influence on the sampling rate of the passive sampler. However, the increase of flow velocity on the surface of sampler resulted in the increase of sampling rate.
Long-term passive diffusive samplers(PDS) have been used to measure $NO_2\;and\;SO_2$ concentrations at 21 sampling sites in Daejeon, Korea during the period of January 2000 - December 2002. The spatial distributions of annual $NO_2\;and\;SO_2$ concentrations were mapped. Average annual $NO_2$ concentration over the sampling period was $28.5{\pm}12.5\;ppb$, ranging from 1.2 to 81.7 ppb. Average annual $SO_2$ concentration over the sampling period was $7.7{\pm}4.8\;ppb$, ranging from 0.6 to 26.8 ppb. On average, $NO_2$ concentration was approximately 5.8%(1.6 ppb) larger in 2002. $SO_2$ concentration was decreased by 13%(1.1 ppb) during the sampling period. The seasonal variation of $NO_2\;and\;SO_2$ concentration was observed with a tendency to be higher in fall and winter. $NO_2\;and\;SO_2$, concentrations measured at different site types(patterns of land use) show significant difference. The observed difference in concentration was associated with difference in emissions of $NO_2$ from motor vehicles and $SO_2$ by non-traffic fuel consumption for heating.
Journal of Korean Society for Atmospheric Environment
/
v.24
no.2
/
pp.143-152
/
2008
This study investigates the variation and spatial distribution of nitrogen dioxide($NO_2$) concentrations measured with passive diffusive samplers at 40 curbside points in Daejeon. Average $NO_2$ concentration was $39.8{\pm}18.0\;ppb$ (n=1,127) and the significant difference in concentrations by regional groups (Dong-gu, Jung-gu, Seo-gu, Daedeok-gu, Yuseong-gu) was not observed. The frequency distribution of $NO_2$ concentration was found to be a normal distribution with the high frequency in the concentration range of 30 to 40 ppb (20 to 25%). Average $NO_2$ concentration measured during the rainy periods was lower than that measured during the non-rainy periods and the decrease of concentration by rainfall was about 16% (7 ppb). The variation of $NO_2$ concentrations measured by passive diffusive samplers during the sampling period was similar to that continuously measured at the air quality monitoring station.
Byeon, Sang-Hoon;Stock, Thomas H.;Morandi, Maria T.;Afshar, Masoud;Cross, Jay
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.11
no.1
/
pp.34-41
/
2001
Passive samplers have been used for personal, indoor, and outdoor air monitoring of VOCs at ppb concentrations in community and office environments. The path length of modified passive sampler was shortened, so it was intended to increase an uptake rate. The performance of the modified 3M 3500 organic vapor monitor(OVM) as a tool for assessing exposures to toxic air pollutants in nonoccupational community environments was evaluated using combined controlled test atmospheres of six selected target volatile organic compounds(VOCs): benzene, methyl tert-butyl ether(MTBE), chloroform, 1,4-dichlorobenzene, tetrachloroethylene, and toluene. The experiments were conducted by exposing the dosimeters to concentrations of $50{\sim}100{\mu}g/m^3$ on six face velocity(0.00, 0.02, 0.06, 0.12, 0.20, 0.30 m/sec) for 24 hours. If the uptake rate was increased, that means that we could use the passive sampler more effectively. The uptake rates were increased linearly according to reduce the path length. Although the diffusion path length was shortened, the change of uptake rate was within ${\pm}25%$ of theoretical value, indicating that the modified passive sampler(TM) can be effectively used over the range of concentrations and environmental conditions tested with a 24-h sampling period if the face velocities were over 0.12 m/s for 6 components of VOCs. But when the face velocities were less than 0.12 m/s, uptake rates were reduced more than expected values. So, the passive sampler with the shortened path length should be used at indoor or outdoor environment where the face velocity should be over about 0.10 m/s. If the path length was shortened more, the uptake rate was more effected by starvation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.