• Title/Summary/Keyword: Diffusion-weighted image

Search Result 98, Processing Time 0.019 seconds

Weighted error diffusion in PDP (PDP에서 가중치 오차확산 보정)

  • Jung, Han-Yung;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.179-181
    • /
    • 2005
  • There is asymmetric in horizontal and vertical side of PDP cell. Every vertical line has BM(Black Mask) to improve luminance contrast. When error diffusion is processed in PDP system, these problems make an error bigger. In 4 inch PDP system, every red, green, blue color of test pattern is presented and each luminance is measured. That is called horizontal(H), diagonal right(R), diagonal left(L) and vertical(V). In red channel, high luminance descending order is V-H-R-L. In green channel, V-H-L-R. In blue channel, V-M-R=L. After average luminance of each direction is calculated. new weighted error diffusion(Weighted ED) is proposed. In digital image signal processing, the error in weighted ED is differ from ED's. The image of weighted ED is more less error compare to conventional ED and close to original image. As the gray level linearity and big size panel is adopted, weighted ED could produce good image.

  • PDF

Evaluation of the Usefulness of PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) Technique to Reduce the Magnetic susceptibility artifact (Magnetic susceptibility artifact를 줄이기 위한 PROPELLER 확산강조영상기법의 유용성에 대한 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • This study attempted to examine whether the propeller diffusion weighted image method may remove magnetic susceptibility artifacts caused by metallic materials. A comparison of occurrence rates of magnetic susceptibility artifacts in the four regions, both temporal lobes, pons, and orbit, between b = 0 and b = 1,000 s/mm2 images was made after obtaining echo-planar diffusion weighted image, propeller diffusion weighted image, and ADC map images, respectively, from a total of 20 patients who had MRI shots taken of their brain and were found to be with retained metallic foreign bodies within their teeth using a 3.0T MR scanner. In the case of echo-planar diffusion weighted image technique, the presence of metallic materials may bring in some limits on accurate diagnosis due to magnetic susceptibility artifacts, while the propeller diffusion weighted image technique where magnetic susceptibility artifacts decrease is expected to be more useful in ensuring accurate diagnosis in the clinical context.

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Changes in SNR and ADC According to the Increase in b Value in Liver Diffusion-Weighted Images

  • Cho, Jae-Hwan;Kim, Ham-Gyum
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2012
  • In the present study, changes in signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of the diffusion-weighted images in the normal livers were investigated using changes in b values in 1.5 T MR (magnetic resonance) instruments. Respective diffusion-weighted images and ADC map images were obtained from 20 healthy individuals by increasing b values from 50 to 400 and 800 $s/mm^2$ using 1.5T MR scanner between January 2011 and November 2011. At each ADC map image obtained at each b value, ADCs in the right hepatic lobe, spleen and kidney were measured. As a result, ADCs of the right hepatic lobe, spleen and kidney have gradually decreased in the diffusion-weighted images in accordance with the reduced b value. This outcome may be used as preliminary data for applications to various abdominal diseases.

Analysis of Signal Intensity in Choroid Plexuses by Diffusion Weighted Imaging (확산강조영상의 검사기법에 따른 맥락얼기의 신호강도 분석)

  • Oh, JongKap
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.265-269
    • /
    • 2013
  • This report aims at picturing out the clinical usefulness by analyzing the signal intensity in choroid plexuses which produce cerebrospinal fluids by diffusion weighted imaging. At first, subjects were chosen among the patients who showed high in signal intensity by diffusion weighted imaging. The subjects were taken another test by fluid attenuated inversion recovery diffusion weighted echo planer image(FLAIR-DW-EPI) the signals of fluid attenuation. And it was found that there are differences between the signal intensities of the two methods, which showed that the signal intensity in FLAIR-DW-EPI is equal to or low than, that in the Brain. By this, it is felt that it is helpful to diagnose the disease in choroid plexus by testing another more with FLAIR-DW-EPI methods the patients who showed high in signal intensity in choroid plexus by $T2^*$ diffusion weighted echo planer image($T2^*$-DW-EPI).

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.

The Utility of Single Shot Turbo Spin Echo Technique for Temporal Bone Diffusion Weighted Imaging (관자뼈의 확산강조영상검사 시 Single Shot Turbo Spin Echo 기법의 유용성)

  • Choi, Kwan-Woo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.25-30
    • /
    • 2021
  • The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

Effect of Gd-DTPA on Diffusion in Canine Brain with Hyperacute Stroke (초급성 뇌경색을 일으킨 개에서 Gd-조영제의 주입이 뇌의 확산에 미치는 영향)

  • 김범수;정소령;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.158-165
    • /
    • 2002
  • Purpose : To evaluate the effect of Gd-DTPA on signal intensity of diffusion-weighted magnetic resonance(MR) image and apparent diffuse coefficient (ADC) in dog brain with hype racute stroke. Materials and methods : Experimental canine model of hyperacute cerebral infarction was made by selective intraarterial embolization with particulate embolic material. Diffusion-weighted MR imaging was performed in five dogs at 1 hour after the embolization of internal carotid artery. After intravenous bolus injection of Gd- DTPA, additional 11 diffusion-weighted MR images were serially obtained from 2 minutes to 90 minutes after injection in each dog. The author evaluated findings of hyperacute cerebral infarction on diffusion-weighted MR imaging, and calculated mean signal intensity and mean ADC in infarcted region and contralateral normal region. Statistical analysis of mean signal intensity, mean ADC and contrast-noise ratio before and after Gd-DTPA injection was performed. Results : Hyperacute cerebral infarction developed in all five dogs on diffusion-weighted MR images obtained 1 hour after embolization. The area of hyperacute infarction had steady increase in signal intensity on diffusion-weighted MR image and decrease in ADC. In normal perfusion area, decrease in signal intensity was observed at 2 minutes the Gd-DTPA injection, whereas ADC did not changed. Conclusion : Intravenous injection of Gd-DTPA had no influence on ADC in both hyperacute infarction and normally perfused are a, but caused initial transient signal reduction in normally perfused area on diffusion-weighted MR image due to susceptibility effect of Gd-DTPA. It is important to calculate ADC in evaluating the effect of diffusion after injection of Gd-DTPA.

  • PDF

Electron Microscopy and MR Imaging Findings in Embolic Effects

  • Park Byung-Rae;Koo Bong-Oh
    • Biomedical Science Letters
    • /
    • v.10 no.4
    • /
    • pp.367-373
    • /
    • 2004
  • Evaluated the hyperacute embolic effects of triolein and oleic acid in cat brains by using MR image and electron microscopy. In fat embolism, free fatty acid is more toxic than neutral fat in terms of tissue damage. T2-Weighted imaging, diffusion-weighted imaging, and contrast-enhanced T1-weighted imaging were performed in cat brains after the injection of triolein (group 1, n=8) or oleic acid (group 2, n=10) into the internal carotid artery. MR image were quantitatively assessed by comparing the lesions with their counterparts on T2-weighted images, apparent diffusion coefficient (ADC) maps, and contrast-enhanced T1-weighted images. Electron microscopic findings in group 1 were compared with those in group 2. Qualitatively, MR images revealed two types of lesions. Type 1 lesions were hyperintense on diffusion-weighted images and hypointense of ADC maps. Type 2 lesions were isointense or mildly hyperintense on diffusion-weighted images and isointense on ADC maps. Quantitatively, the signal intensity rations of type 1 lesions in group 2 specimens were significantly higher on T2-weighted images (P=.013)/(P=.027) and lower on ADC maps compared with those of group 1. Electron microscopy of type 1 lesions in both groups revealed more prominent widening of the perivascular space and swelling of the neural cells in groups 1. MR and electron microscopic data on cerebral fat embolism induced by either triolein or oleic acid revealed characteristics suggestive of both vasogenic and cytotoxic edema in the hyperacute stage. Tissue damage appeared more severe in the oleic acid group than in the triolein group.

  • PDF

Nonlinear Anisotropic Diffusion Using Adaptive Weighted Median Filters (적응 가중 미디언 필터를 이용한 영상 확산 알고리즘)

  • Hwang, In-Ho;Lee, Kyung-Hoon;Kim, Woong-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.542-549
    • /
    • 2007
  • Recently, many research activities in the image processing area are concentrated on developing new algorithms by finding the solution of the 'diffusion equation'. The diffusion algorithms are expected to be utilized in numerous applications including noise removal and image restoration, edge detection, segmentation, etc. In this paper, at first, it will be shown that the anisotropic diffusion algorithms have the similar structure with the adaptive FIR filters with cross-shaped 5-tap kernel, and this relatively small-sized kernel causes many iterating procedure for satisfactory filtering effects. Moreover, it will also be shown that lots of modifications which are adopted to the conventional Gaussian diffusion method in order to weaken the edge blurring nature of the linear filtering process increases another computational burden. We propose a new Median diffusion scheme by replacing the adaptive linear filters in the diffusion process with the AWM (Adaptive Weighted Median) filters. A diffusion-equation-based adaptation scheme is also proposed. With the proposed scheme, the size of the diffusion kernel can be increased, and thus diffusion speed greatly increases. Simulation results shows that the proposed Median diffusion scheme outperforms in noise removal (especially impulsive noise), and edge preservation.