• Title/Summary/Keyword: Diffusers

Search Result 159, Processing Time 0.022 seconds

An Estimation on Indoor Thermal Environment by Pressurized Plenum Under Floor Air Conditioning System in Heating (난방시 가압식 바닥취출 공조방식의 실내온열환경 평가)

  • Choi, Eun-Hun;Lee, Yong-Ho;Kwon, Young-Cheol;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.92-99
    • /
    • 2010
  • The purpose of this study is to apply pressurized plenum under floor air conditioning system to office areas to understand characteristics of indoor thermal environment based on forms of diffusers. For doing this, the author conducted experiment of module measurement, and based on the results, analyzed indoor temperature distribution and velocity distribution based on direction of diffusion by using Computational Fluid Dynamics(CFD), and estimated the Predicted Mean Vote(PMV) of residents based on forms of diffusers to present the optimal air conditioning of the pressurized plenum under floor air conditioning system in heating. The results of this study are as follows. First, as for forms of diffusers, distributed diffusers rather than conical and grill diffusers were favorable in maintaining $24^{\circ}C$, the established temperature in heating, were active in velocity flowing, and were wide in a radius of diffusion. Second, as for position of pressurizing, the difference between upper and lower temperature was wider in center, lateral, and dispersed pressurizing (in order). As for velocity distribution, the velocity was more increased in lateral, center, and dispersed pressurizing(in order), indicating that dispersed pressurizing maintained uniform thermal environment. Third, as for diffusion direction, mixed direction showed less difference between upper and lower temperature and the difference in velocity between center and lateral part was 0.01m/1, indicating that it maintained uniform thermal environment. Fourth, as for the PMV of residents based on the forms of diffusers, the dispersed type showed(+) values above (0) when applied variably based on the position of diffuser, presenting thermal feeling of "being comfortable" to residents.

Study on Starting Pressure of Supersonic Exhaust Diffusers to Simulate high Altitude Environment (고고도 모사용 초음속 디퓨져의 시동압력에 대한 연구)

  • Yoon, Sang-Kyu;Yeom, Hyo-Won;Kim, Jin-Kon;Sung, Hong-Gye;Kim, Yong-Wook;Oh, Seung-Hyup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.4
    • /
    • pp.16-23
    • /
    • 2008
  • Theoretical and numerical approaches were conducted in order to study supersonic exhaust diffusers to simulate high altitude performance of rockets on the ground. A physical model of concern includes a rocket motor, vacuum chamber, and diffuser, which have axisymmetric configurations. An analysis was conducted to investigate operation characteristics of supersonic exhaust diffusers from a flow-development point of view. Emphasis was placed on theoretical formulation to predict the starting pressure of diffusers, the effect of the vacuum chamber size, and the minimum starting pressure of the rocket motor to start the diffuser.

Study on Design of Secondary Throat Supersonic Exhaust Diffusers (2차목 초음속 디퓨저 설계에 관한 연구)

  • Park, Jin-Ho;Lee, Yang-Suk;Kim, Joong-Il;Ko, Young-Sung;Kim, Sun-Jin;Kim, Yoo;Kim, Seung-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.881-884
    • /
    • 2011
  • Secondary throat supersonic exhaust diffusers were designed by Normal-shock theory and manufactured. Experimental studies of the diffusers were performed using nitrogen gas of room temperature. It showed a difference about 18% between the experimental and theoretical results. The difference was shown by friction loss at the wall of the diffuers.

  • PDF

PERFORMANCE BY WIDTH CONTRACTION IN VANELESS DIFFUSER OF CENTRIFUGAL COMPRESSOR BY COMPUTATIONAL FLUID DYNAMICS (전산해석을 통한 원심압축기용 디퓨저의 폭변화에 따른 성능 연구)

  • Lee, S.C.;Lee, W.S.;Shin, Y.H.;Chung, J.T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.136-141
    • /
    • 2010
  • This study describes effects of width contraction in vaneless diffuser on the performance of centrifugal compressors using commercial CFD code. Numerical analysis for three different diffusers such as Parallel, half contraction, and full contraction was performed. The results show that the performance of the centrifugal compressor is improved through the use of the diffusers with width parallel in high flow rate. The width contraction of diffusers is influenced static pressure rises. Comparison with the experimental data shows agreement.

  • PDF

Blade Shape Design of Mixed-flow Pump Impellers and Diffusers in a Fixed Meridional Geometry (자오면 고정 형상에서 사류펌프 임펠러 및 디퓨져 날개형상 설계)

  • Kim, Sung;Choi, Young-Seok;Lee, Kyoung-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1203-1208
    • /
    • 2009
  • In this paper, the flow characteristics of the mixed-flow pump impellers and diffusers were numerically predicted by commercial CFD software and DOE(design of experiments). We also discussed how to improve the performance of the mixed-flow pump by designing the impeller and diffuser in the mixed-flow pump. Geometric design variables were defined by the vane plane development which indicates the blade-angle distributions and length of the impeller and the diffusers. Firstly, the design optimization of the defined impeller geometric variables has been done. After that, the flow characteristics were analyzed in the point of incidence angle at the diffuser leading edge for the optimized impeller. Then design of the defined diffuser shape variables has been performed. The reason for the performance improvement was discussed by examining the flow characteristics through the diffuser.

  • PDF

Piezoelectric-Actuated Polydimethylsiloxane(PDMS) Micropump with Diffusers (압전 구동 방식의 Polydimethylsiloxane(PDMS) 마이크로 펌프)

  • 김진호;김영호;김용상
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.487-491
    • /
    • 2003
  • The low-cost, simple structured micropump which is actuated by piezoelectric-discs, is fabricated with polydimethylsiloxane (PDMS) and the performances of the micropump, such as pump rate and backpressure, are characterized. The PDMS micropump with diffusers instead of passive check valves as a flow-rectifying element was fabricated. The deflection of glass diaphragm measured by atomic force microscope (AFM) is about 0.4$\mu\textrm{m}$ when applying a 150V square wave voltage at 300Hz across a 300${\mu}\ell$ thick piezoelectric disc. While the square wave driving voltage is applied to the piezoelectric disc of the actuator, the flow rate is measured by fluid displacement variation of the outlet tube. The flow rate of micropump increases with enhancing the applied voltage due to the increase of diaphragm deflection. The flow rate and the backpressure of the micropump with diffusers are about 32.9${\mu}\ell$/min and 173Pa respectively for the above mentioned deflection conditions.

Investigation of influence of linear diffuser in the ventilation of operating rooms

  • Keshtkar, Mohammad Mehdi;Nafteh, Maryam
    • Advances in Energy Research
    • /
    • v.4 no.3
    • /
    • pp.239-253
    • /
    • 2016
  • Air quality in hospitals has always concerned hospitals' health officials due to its dangerous particles and gases. Because of the importance of air conditioning in the operating room, a system must be embedded in operating rooms to direct the contaminated air outside, and inject fresh filtered air from outside back into the room. In this study, laminar flow air conditioning system is implemented in the operating room by slot linear diffusers and with the help of air curtain. For this, stimulation Computational Fluid Dynamic (CFD) was used due to its efficiency. The aim of the present study was to find a proper solution to overcome the unfavorable factors, namely, contamination, humidity, and also temperature, velocity and pressure inside the room. These factors were implemented with different values and then stimulated through FLUENT software program. Results showed that the aforementioned factors can be overcome using air curtain and slot linear diffusers.

Improvement of Optical and Thermo-mechanical Properties of Polycarbonate-based Diffusers for LED Backlight Unit by Incorporation of Porous Silica Particles (실리카 다공체에 의한 발광다이오드 백라이트 유닛용 폴리카보네이트계 확산판의 광학 및 열-기계적 물성의 향상 연구)

  • Kim, Hyo Jin;Kim, Dong Won;Kim, Seong Woo
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.761-767
    • /
    • 2012
  • The polycarbonate (PC)-based optical diffusers for direct-lit LED backlight unit were prepared by using extrusion compounding followed by compression molding process. The application of inorganic porous silica particles as a diffusing agent in addition to conventional poly(methyl methacrylate) (PMMA) beads was attempted, and the optical, thermal, and mechanical properties of the prepared diffusers were investigated. The morphological observations revealed that the diffusing agents could be uniformly dispersed in the PC matrix without agglomeration by high shear stress generated during extrusion process. The incorporation of the porous silica particles mixed with PMMA beads remarkably enhanced the luminance uniformity with respect to both location and view angle for the diffuser, while minimizing the reduction in the absolute luminance, as compared with the diffuser containing only PMMA beads. In addition, thermal and mechanical properties of the diffusers were shown to be improved upon addition of the porous silica particles.

Fabrication of 3D Micro Structure by Dual Diffuser Lithography (듀얼 디퓨저 리소그래피를 이용한 3 차원 마이크로 구조의 제작)

  • Han, Dong-Ho;Hafeez, Hassan;Ryu, Heon-Yul;Cho, Si-Hyeong;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.23 no.8
    • /
    • pp.447-452
    • /
    • 2013
  • Recently, products that a have 3-dimensional(3D) micro structure have been in wide use. To fabricate these 3D micro structures, several methods, such as stereo lithography, reflow process, and diffuser lithography, have been used. However, these methods are either very complicated, have limitations in terms of patterns dimensions or need expensive components. To overcome these limitations, we fabricated various 3D micro structures in one step using a pair of diffusers that diffract the incident beam of UV light at wide angles. In the experiment, we used positive photoresist to coat the Si substrate. A pair of diffusers(ground glass diffuser, opal glass diffuser) with Gaussian and Lambertian scattering was placed above the photomask in the passage of UV light in the photolithography equipment. The incident rays of UV light diffracted twice at wider angles while passing through the diffusers. After exposure, the photoresist was developed fabricating the desired 3D micro structure. These micro structures were analyzed using FE-SEM and 3D-profiler data. As a result, this dual diffuser lithography(DDL) technique enabled us to fabricate various microstructures with different dimensions by just changing the combination of diffusers, making this technology an efficient alternative to other complex techniques.

Improvement of Field Uniformity in the Reverberation Chamber Using Diffusers Filled with Dielectric Material (유전체로 충진된 확산기를 이용한 전자파 잔향실 내의 전자기장 균일도 향상 연구)

  • Kim Hye-Kwang;Rhee Joong-Geun;Lim Wook-Chae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.12 s.103
    • /
    • pp.1222-1228
    • /
    • 2005
  • Analysis on the field uniformity inside of a reverberation chamber was done at 2.45 GHz which is an operating frequency of MWO(Microwave Oven). The Schroeder's Quadratic Residue Diffuser was designed for the chamber, and 3 different types of diffusers have been investigated using the finite-difference time-domain(FDTD) method for the field characteristics of each type. Type 2 and 3 diffusers were filled with dielectric material, and the size of these could be designed smaller than Type 1, without degradation of field characteristic. Type 3 diffuser shows better results among the three types of diffusers in view of increased test region and better field uniformity.