• Title/Summary/Keyword: Diffuse Sound Field

Search Result 22, Processing Time 0.034 seconds

Experimental study for characteristics of diffuse sound field formed by sound source directivity (음원의 지향성이 확산음장 형성에 미치는 영향에 관한 실험연구)

  • Shin, Il-Seop;Cha, Kwang-Seok;Cho, Chang-Geun;Lee, Dae-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1002-1006
    • /
    • 2000
  • It is diffuse sound field that measuring condition of absorption ratio and sound transmission loss for material consist of building are measured in reverberartion room and on-site. In this study, for upkeeping diffuse sound field in reverberation room, it is measured and etimated that sound field is effected according to sound source lacation and characteristics of emission directivity for sound source.

  • PDF

Study on method of build up low-frequency diffuse sound field in a scaled reverberation chamber (축소잔향실의 저주파수 확산음장 형성 방법에 대한 연구)

  • Kang, Jun-Goo;Kang, Hyun-Ju;Kim, Sang-Ryul;Choi, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.61-64
    • /
    • 2007
  • This study is dealt with a method to enhance low-frequency diffuse sound field in a scaled reverberation chamber. Because scaled reverberation chamber has not enough room volume, as a result, it shows a few room modes. So it is not build up low-frequency diffuse sound field. A Helmholtz resonator's arrangement is used to improve spatial uniformity of sound pressure at low frequency. The spatial distribution of sound field has been measured before and after control. The standard deviation of sound field has decreased at 315Hz 1/3 Octave band.

  • PDF

Sound Transmission Loss of Double Panels(I) : A Double Wall with Air Cavity (이중판의 차음손실 I)

  • 강현주;김현실;김재승;김상렬
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.945-952
    • /
    • 1997
  • This paper shows the feasibility of the suggestion that the angle distribution of incident sound to panels might be gaussian, instead of the conventional uniform distribution in the analysis of transmission loss of panels. To prove the suggestion, the problems with the diffuse sound field in a reverberation room are examined by case studies and the comparision of the prediction with the measurement of sound transmission loss of walls are performed. The results of the comparision show good agreement between the two values.

  • PDF

Ambisonic Rendering for Diffuse Sound Field Simulations based on Geometrical Acoustics (기하음향 기반 확산 음장 시뮬레이션을 위한 앰비소닉 렌더링 기법)

  • Pilsun Eu;Franz Zotter;Jae-hyoun Yoo;Jung-Woo Choi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.11a
    • /
    • pp.26-29
    • /
    • 2022
  • The diffuse sound field plays a crucial role in the perceptual quality of the auralization of virtual scenes. Diffuse Rain is a geometrical scattering model which enables the simulation of diffuse fields that is compatible with acoustic ray tracing, but is often computationally expensive. We develop a novel method that can reduce this cost by rendering the large number of Diffuse Rain data in Ambisonics format. The proposed method is evaluated in a shoebox scene simulation run on MATLAB, in reference to a more faithful method of rendering the Diffuse Rain data ray-by-ray. The EDC and IACC of the binaural output show that the simulated diffuse field can be rendered in Ambisonics with only minimal deviations in energy decay and spatial quality, even with 1st-order Ambisonics.

  • PDF

Topology Optimization of an Acoustic Diffuser Considering Reflected Sound Field (반사 음장을 고려한 음향 확산 구조의 위상 최적 설계)

  • Yang, Jieun;Lee, Joong Seok;Kim, Yoon Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.973-981
    • /
    • 2013
  • The main role of an acoustic diffuser is to diffuse reflected sound field spatially. Since the pioneering work of Schroeder, there have been investigations to improve its performance by using shape/sizing optimization methods. In this paper, a gradient-based topology optimization algorithm is newly presented to find the optimal distribution of reflecting materials for maximizing diffuser performance. Time-harmonic acoustic analysis in a two-dimensional acoustic domain is carried out where the domain is discretized by finite elements. Perfectly matched layers are placed to surround the domain to simulate non-reflecting boundary conditions. Design variables are assigned to each element of which material properties are interpolated between those of air and those of a rigid body. An approach to extract the reflected field from the total acoustic field is employed. To validate the effectiveness of the proposed method, design problems are solved at different frequencies. The performance of the optimized diffusers obtained by the proposed method is compared against that of the conventional Schroeder diffusers.

A Study on Room Acoustic Field Analysis using Radiosity Method (라디오시티법을 이용한 실내 음향장 해석 연구)

  • Kim, Kookhyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.5
    • /
    • pp.394-400
    • /
    • 2018
  • Various numerical methods have been adopted for indoor noise assessments of ship plant. Acoustical radiosity method is one of the high frequency approaches for acoustic field analysis, which assumes diffuse reflections by boundaries so that it could be efficiently applied to the acoustically diffused indoor space noise analysis. In this study, an acoustic field analysis program has been developed based on radiosity method, which could apply for acoustically large enclosures such as ship's indoor space. For this purpose, the procedure of the acoustical radiosity method has been summarized and implemented to an acoustic field analysis program using MATLAB. Numerical example for a rectangular indoor space has investigated validity of the implemented program. Steady state sound pressure levels calculated for a continuous acoustic source signal have shown good agreement with those by other solutions such as an analytic solution and a ray tracing method. Instantaneous sound pressure levels calculated for an impulsive acoustic signal have provided the clues of direct/reflected acoustic field and reverberation time.

Experimental evaluation of sound Insulation performance of ceiling panels (천장재 차음성능의 실험 평가)

  • 강현주;김상렬;김재승;김현실;김봉기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1067-1070
    • /
    • 2002
  • This paper deals with the factors affecting measurement of sound insulation performance of the ceiling panels. The factors to be experimently examined are as follows: sound diffuseness of the test room by investigating sound pressure distribution, Reverberation time, and influence of speaker location on measured results. Based on the investigation of sound pressure distribution over measuring points, it can draw a conclusion that rectangular shaped rooms as test rooms have a serious problem associated with the diffuse sound field.

  • PDF

The Study on Correction Factor of a Small Scale Reverberation Chamber to Estimate Transmission Loss (소형 잔향실의 확산 음장 보정 계수 측정 연구)

  • Kim, Tae Min;Kim, Da Rae;Kim, Jeung Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.960-965
    • /
    • 2014
  • Transmission loss of specimen is calculated by measuring energy of incident and transmission and using reverberant room of large size. But normal measurement of transmission loss has trouble because it is actually demanded that large area and specimen of certain size is satisfied with condition of diffused sound field. Especially, in case of mechanical component, interested frequency band is mid-frequency band between 500 ~ 2k Hz, and it is used to be available to minimize a reverberation chamber under conditions satisfying acoustic one because production of specimen for transmission loss measurement has limit. But, as in semi-reverberation room, it is difficult to satisfy condition of diffuse sound field and modification factor is applied to complement that. Correction factor when measuring transmission loss using semi-reverberation chamber is required accuracy because it works as main factor determining reliability of reuslts on transmission loss. In this study, it is analyzed that an effect on correction factor based on varying materials and sizes of specimens in order to deduction of it. Also It is confirmed that applied by elicited correction factor with actual railway vehicle's floor has reliability.

  • PDF

Sound Energy Distributions according to Incident Angles on the Bounding Surfaces in the Reverberation Room (잔향실 경계면에서 입사각에 따른 음에너지 분포)

  • 강현주;이정권;김현실;김재승;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.279-285
    • /
    • 1997
  • In this paper, the validity for the application of the diffuse sound field theory to the real sound filed, especially on the bounding surfaces of the rooms, was studied. Numerical simulations using ray tracing technique for two models, namely spheres and a reverberant room, were performed. Calculation results show that the distribution of the incident sound energy vs incident angles is approximated to Gaussian distribution, not to the uniform distribution.

  • PDF

Reconsideration on the Diffsuse Sound Field (확산음장에 관한 고찰)

  • 강현주
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.331.2-336
    • /
    • 1998
  • In this paper, the validity for the application of the diffuse sound field theoty to the real sound field, especially on the bounding surfaces of the rooms, was reconsidered. The analytical result for directivity pattern on the bounding surfaces of the room was compared with the result of numerical simulations using ray tracing technique. Comparison results show that the distribution of the incident sound energy vs incident angles is approximated to Gaussian distribution, not to the uniform distribution.

  • PDF