• Title/Summary/Keyword: Diffuse Radiation

Search Result 159, Processing Time 0.028 seconds

Relationship between Hourly Clearness Index and Diffuse Ratio at Cheongju Area(II) (청주지방(淸州地方)의 시청명지수(時淸明指數)와 산란비(散亂比)와의 관계(關係)(II))

  • Lee, H.J.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.2
    • /
    • pp.46-50
    • /
    • 1988
  • The estimation of beam radiation intensity on a tilted surface is very important to the design of a solar energy system. In order to get the beam radiation intensity, it is required to calculate the ratio of the diffuse solar radiation to the global radiation ($k_d$). The data measured at Chung-Buk National University. Cheong-ju, (from May 16, 1985 to Nov, 10, 1987) were analysed to define the relationship between hourly clearness index ($k_t$) and diffuse ratio ($t_d$). The results are is follow: 1. The percent of clearness index($k_t$) of less than 0.3 and of more than 0.8 were 2.7% and 3.1% respectively, and between 0.5 and 0.8 was 76.5%. 2. The regression equation between $k_t$ and $k_d$ was an exponential function as: $$k_d=\[{1\hspace{120}:\hspace{10}(k_t<0.1)\\1.28{\times}0.074^{k_t}\hspace{30}:\hspace{10}(0.1{\leq}=k_t<0.9)\\0.12\hspace{98}:\hspace{10}(0.9{\leq}=k_t)$$ There was a little difference between the result. of this study based on the data of 30 months and the results of previous study (ITRA 2(1):42-47, 1986.) based on the data of 8 months. 3. The hourly exponential regression equation between $k_t$ and $k_d$ was $k_d=A{\times}8^{k_t}$ and the values of constant A and coefficient B of the: equations are as the following table; 4. The percent of $k_d$ of less than 0.4 was 72.9% and of more than 0.7 was 6.6%. 5. Total mean value of $k_t$ and $k_d$ wert 0.56 and 0.32, respectively. From 10:00 to 15:00 o'clock the total mean value of $k_t$ was smaller that the hourly man value of $k_t$ and the one or $k_d$ larger.

  • PDF

Feasibility of Gamma Knife Radiosurgery for Brain Arteriovenous Malformations According to Nidus Type

  • Ja Ho Koo;Eui Hyun Hwang;Ji Hye Song;Yong Cheol Lim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.431-441
    • /
    • 2024
  • Objective : Gamma Knife radiosurgery (GKRS) is an effective and noninvasive treatment for high-risk arteriovenous malformations (AVMs). Since differences in GKRS outcomes by nidus type are unknown, this study evaluated GKRS feasibility and safety in patients with brain AVMs. Methods : This single-center retrospective study included patients with AVM who underwent GKRS between 2008 and 2021. Patients were divided into compact- and diffuse-type groups according to nidus characteristics. We excluded patients who performed GKRS and did not follow-up evaluation with magnetic resonance imaging or digital subtraction angiography within 36 months from the study. We used univariate and multivariate analyses to characterize associations of nidus type with obliteration rate and GKRS-related complications. Results : We enrolled 154 patients (mean age, 32.14±17.17 years; mean post-GKRS follow-up, 52.10±33.67 months) of whom 131 (85.1%) had compact- and 23 (14.9%) diffuse-type nidus AVMs. Of all AVMs, 89 (57.8%) were unruptured, and 65 (42.2%) had ruptured. The mean Spetzler-Martin AVM grades were 2.03±0.95 and 3.39±1.23 for the compact- and diffuse-type groups, respectively (p<0.001). During the follow-up period, AVM-related hemorrhages occurred in four individuals (2.6%), three of whom had compact nidi. Substantial radiation-induced changes and cyst formation were observed in 21 (13.6%) and one patient (0.6%), respectively. The AVM complete obliteration rate was 46.1% across both groups. Post-GKRS complication and complete obliteration rates were not significantly different between nidus types. For diffuse-type nidus AVMs, larger AVM size and volume (p<0.001), lower radiation dose (p<0.001), eloquent area location (p=0.015), and higher Spetzler-Martin grade (p<0.001) were observed. Conclusion : GKRS is a safe and feasible treatment for brain AVMs characterized by both diffuse- and compact-type nidi.

Combined Arthroscopic Gross Total Synovectomy and Radiotherapy for Diffuse Pigmented Villonodular Synovitis of the Knee: A Report of 2 Cases (무릎관절의 미만형 색소 융모 결절성 활액막염에서 관절경을 이용한 육안적 활액막 전 절제술 후 방사선치료: 증례보고)

  • Chang, Sei-Kyung;Kim, Jae-Hwa;Ha, Doo-Hoe;Kang, Hae-Youn;Chong, So-Young;Shin, Hyun-Soo
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.201-206
    • /
    • 2006
  • Pigmented villonodular synovitis (PVNS) is a rare proliferative disease involving synovial membranes. Natural history and etiology of PVNS are not well known. PVNS presents as localized or diffuse tumor like nodular lesion of the synovial lining of the joint and the synovial spaces adjacent to the joints. Though histologically benign, it is a very aggressive lesion, capable of bone destruction and widespread infiltration of surrounding tissues. Standard therapy is surgical resection, but due to the infiltrative growth, the recurrence rate is significantly high. After several relapses surgical treatment of diffuse PVNS becomes difficult and may require amputation of the involved limb. Radiotherapy can provide an effective treatment option for patients with large lesions or lesions which are not suitable for surgery, after incomplete resection to prevent relapses or to avoid amputation. We report 2 cases of diffuse PVNS in the knee joint treated with arthroscopic gross total synovectomy and radiotherapy.

Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray (흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화)

  • Kim Yong;Seo Tae-Beom;Kang Yong-Heack
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

Combined Modality Therapy of Non-Hodgkin's Lymphoma of Waldeyer's Ring (Waldeyer's Ring 비호치킨 림프종의 병합요법)

  • Park In-Kyu;Yun Sang-Mo;Park Jun-Sik;Kim Jae-Cheol
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.1
    • /
    • pp.22-28
    • /
    • 1999
  • Purpose: We performed this study retrospectively to evaluate local control, survival, prognostic factors, and failure patterns in patients with non-Hodgkin's lymphoma of Waldeyer's ring. Materials and Methods: From April 1984 to November 1996,41 patients with non-Hodgkin's lymphoma of Waldeyer's ring were treated with combined chemotherapy and radiation therapy. Age was ranged from 19 to 73 years old with a median age of 55 years, and there were 26 male and 15 female patients. Primary site was tonsil in 26 and base of the tongue in 7 and nasopharynx in 8, and stage distribution showed stage I in 12 and stage II in 29 patients. Pathologic classification was done according to Working Formulation. There were 1 with follicular mixed small cleaved and large cell, 8 with diffuse small cleaved cell, 7 with diffuse mixed small and large cell, and 25 cases with diffuse large cell. All patients were treated with combination of chemotherapy and radiation therapy. Chemotherapy regimen consisted of either CHOP-Bleo(cyclophosphamide, adriamycin, vincristine, prednisolone, bleomycin) or COP-BLAM III(cyclophosphamide, vincristine, prednisolone, bleomycin, adriamycin, procarbazine). Radiation dose ranged from 3600cGy to 6620cGy with a median dose of 5040cGy. Follow-up time was ranged from 15 months to 159 months(median 55 months). Results: The complete response was achieved in 98%(40/41) and partial response in 2%(1/41). The complete response rate were the followings: 66.7% for stage I and 51.7% for stage II after chemotherapy, 100% for stage I and 96.6% for stage II after overall treatment respectively. The overall survival rate and disease-tree survival rates at 5 years were 82.6% and 79.5%, respectively. Prognostic factors for overall survival were age(p=0.007), stage(p=0.03), nodal status(p=0.006) and radiation dose(p=0.003). The factors associated with disease-tree survival were stage(p=0.04), nodal status(p=0.004) and radiation dose(p=0.009). The failure patterns were analized in evaluable 35 patients with complete response. Locoregional failure was noted in 2 patients and distant metastasis in 5 patients. Conclusion: Our results suggest that combined modality therapy is the appropriate treatment for stage I-II intermediate grade non-hodgkin's lymphoma of the Waldeyer's ring. However, our material is small and the analysis is retrospective. Randomized prospective studies for combined therapy, radiation therapy alone and chemotherapy alone are needed.

  • PDF

Analysis of Solar Irradiance Measurement From a Multi-Filter Radiometer At Kwangju, South Korea.

  • Ogunjobi, K.O.;Kim, Y.J.;He, Z.;Ryu, S.Y.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.335-335
    • /
    • 2001
  • Direct-normal, total horizontal and diffuse horizontal irradiance data obtained from a multi-filter rotating shadowband radiometer over seven different wavelength bands (416nm, 151nm, 616nm, 675nm, 870nm and 940nm and the entire spectrum) has been analyzed at Kwangju, South Korea from June 1998 December 2000. The maximum hourly global radiation flux ranged from 0.44 MJ/$m^2$ to 2.68 MJ/$m^2$ at around 11:00-12:00 Hr local time while the maximum hourly diffuse radiation flux ranged from about 0.96 MJ/$m^2$ to 1.37 MJ/$m^2$. The maximum hourly direct irradiance ranged from 1.42 MJ/$m^2$ to 2.92 MJ/$m^2$ from June1998-2000. During the period under consideration, the average monthly global radiation recorded were 13.09 MJ/$m^2$/day, 10.58MJ/$m^2$/day and 9.78MJ/$m^2$/day for years 1998, 1999 and 2000 respectively, while the diffuse irradiance were 6.54 MJ/$m^2$/day, 5.33 MJ/$m^2$/day and 5.14 MJ/$m^2$/day for f998, 1999 and 2000 respectively. The direct irradiance values at the site were 11.63 MJ/$m^2$/day, 8.24MJ/$m^2$/day and 7.75 MJ/$m^2$/day for 1998, f999 and 2000 respectively. It was observed that each of the years has its own unique meteorological parameters that affect the quality and quantity of radiation received for each month. The annual average daily fractions of the diffuse to the global radiation (KD) were 0.51, 0.61 and 0.59 for years 1998, 1999 and 2000 respectively. Analysis indicated that the average daily KD ranged from 0.13 to a maximum value of 0.99 in May for irradiance measured at the broadband channel while the maximum and minimum KD value of 0.91 and 0.23 was recorded at wavelength band 870nm and 940nm in January and September respectively. The lowest average daily clearness index (Kt) value recorded was 0.03 in May (Spring) and the annual average daily clearness indexes are 0.45, 0.34 and 0.35 for years 1998, f999 and 2000 respectively. The frequency of clear days annually at Kwangju is 67.95%, 29.57% and 40.72% for years 1998, 1999 and 2000 respectively.

  • PDF

GALAXY CLUSTERS IN GAMMA-RAYS: AN ASSESSMENT FROM OBSERVATIONS

  • REIMER OLAF
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.307-313
    • /
    • 2004
  • Clusters of galaxies are believed to constitute a population of astrophysical objects potentially able to emit electromagnetic radiation up to gamma-ray energies. Evidence of the existence of non-thermal radiation processes in galaxy clusters is indicated from observations of diffuse radio halos, hard X-ray and EUV excess emission. The presence of cosmic ray acceleration processes and its confinement on cosmological timescales nearly inevitably yields in predicting energetic gamma-ray emission, either directly deduceably from a cluster's multifreqency emission characteristics or indirectly during large-scale cosmological structure formation processes. This theoretical reasoning suggests several scenarios to actually detect galaxy clusters at gamma-ray wavelengths: Either resolved as individual sources of point-like or extended gamma-ray emission, by investigating spatial-statistical correlations with unidentified gamma-ray sources or, if unresolved, through their contribution to the extragalactic diffuse gamma-ray background. In the following I review the situation concerning the proposed relation between galaxy clusters and high-energy gamma-ray observations from an observational point-of-view.

Transient Radiative Heat Transfer Using Finite Volume Method with 2-Order Upwind Scheme and QUICK Scheme (비정상상태 복사열전달 해석을 위한 2 차 상류스킴 및 QUICK 스킴의 유한체적복사해법 적용 연구)

  • Byun, Do-Young;Lee, Gun-Ho;Kim, Man-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1294-1299
    • /
    • 2004
  • Transient radiative heat transfer is analyzed in a one-dimensional slab using finite volume method (FVM). In this study, the step, $2^{nd}$ order upwind, and QUICK schemes are used for incident diffuse radiation and collimated beam, respectively. The results for diffuse radiation show that all schemes applied in this study give good agreements with available published results. In case of collimated beam, however, the results show deviations from the analytical solutions. To successfully describe the propagations of collimated beam, shock capturing schemes such as TVD scheme are need to be developed.

  • PDF

1- Dimensional Transient Radiative Heat Transfer Using Finite Volume Method with 2-Order Upwind Scheme and QUICK Scheme (1차원 비정상상해 복사열전달 해석을 위한 2차 상류스킴 및 QUICK 스킴의 유한체적복사해법 적용 연구)

  • Lee Gun-Ho;Kim Man-Young;Byun Do-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.201-207
    • /
    • 2006
  • Transient radiative heat transfer is analyzed in a one-dimensional slab using finite volume method (FVM). In this study, the step, $2^{nd}$ order upwind, and QUICK schemes are used for incident diffuse radiation and collimated beam, respectively. The results fer diffuse radiation show that all schemes applied in this study give good agreements with available published results. In case of collimated beam however, the results show deviations from the analytical solutions. To successfully describe the propagations of collimated beam shock capturing schemes such as TVD scheme are need to be developed.