• 제목/요약/키워드: Differential-mode

Search Result 605, Processing Time 0.027 seconds

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Numerical Analysis for Separation of Methane by Hollow Fiber Membrane with Cocurrent Flow (병류흐름 중공사 분리막에 의한 메탄 분리 수치해석)

  • Lee, Seungmin;Seo, Yeonhee;Kang, Hanchang;Kim, Jeonghoon;Lee, Yongtaek
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • A theoretical analysis was carried out to examine the concentration behavior of methane from a biogas using a polysulfone membrane. After the governing equations were derived for the cocurrent flow mode in a membrane module, the coupled nonlinear differential equations were numerically solved with the Compaq Visual Fortran 6.6 software. At the typical operating condition of mole fraction of 0.7 in a feed stream, the mole fraction of methane in the retentate increased to 0.76 while the normalized retentate flow rate to the feed flow rate decreased from 1 to 0.79. When either the mole fraction of methane in a feed increased or the pressure of the feed stream increased, the methane mole fraction in the retentate increased. On the other hand, it was found that as either the membrane area decreased or the ratio of the permeate pressure to the feed pressure increased, the methane mole fraction in the retentate decreased. In case that the stage cut increased, the methane mole fraction in the retentate increased while the recovery of methane slightly decreased.

Pin Distribute Method of Twist Cable at Military Unmanned Vehicle Wiring Unit Connector (군용 무인 이동체 배선장치 커넥터에서 트위스트 케이블 핀 배치 최적화 방안)

  • Eun, Hee-hyun;Roh, Dong-gyu;Kwak, Gyu-min;Kim, Jae-seung;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.245-250
    • /
    • 2020
  • Currently, unmanned military vehicles under development in Korea have more devices to carry out various missions, and interface cables between them are also increasing. In addition, due to a small space problem inside the unmanned vehicle, devices are required to be miniaturized and integrated. For two reasons, connectors also need to be selected, which makes them vulnerable to noise due to the closer distance between the pins. In this paper, we analyzed how much the magnetic field produced by noise at the connector pin where cable twist is released affects the surrounding pin and presented the guide for optimal pin placement. First, the effect of magnetic field is greater than the crosstalk between pin and pin. Second, the magnetic field on both sides between + and - is strong when approaching one step with noise source. Third, the magnetic field strength is improved when setting the ground pin as the ground pin between the noise and the original signal when approaching the A noise source and the two steps. Fourth, in the case of a differential mode communication, the optimal placement area of the sensitive signal was presented according to positions Tx± and Rx±.

Phytophthora Blight of Pepper and Genetic Control of the Disease (고추 역병과 그 유전적 방제)

  • Kim, Byung-Soo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.3
    • /
    • pp.111-117
    • /
    • 2014
  • Phytophthora blight caused by Phytophthora capsici Leonian is a dangerous disease threatening pepper growers worldwide. The efficacy of chemical control is generally low as the pathogen is soil-borne and rapidly spread by zoospores during the rainy season. Thus, based on the demand for resistant varieties, various good resistant sources, such as CM334, AC2258, and PI201234, have been reported and their inheritance of resistance studied by many different authorities. However, the mode of inheritance remains unclear, as 1 or 2 independent dominant genes, 3 genes, or multiple genes have all been reported as responsible for resistance. Recently, QTL mappings of the gene factors for resistance have been reported, and molecular markers for resistance used in breeding programs. With the release of many resistant commercial hybrid cultivars, differentiation of pathotypes of the pathogen is attracting interest among breeders and plant pathologists. Various authorities have already classified the pathogen strains into different races according to the inter-action between resistant host plants, including the source of resistance, such as CM334 and PI201234, and resistant commercial varieties and P. capsici isolates. However, no standard differential host sets have yet been established, so the results are good only for the pathogen strains used in the experiments. Thus, for breeding varieties with durable resist-ance, it is important to introduce resistance from different sources and use diverse local pathogen strains collected in the target area for distribution in a breeding program.

Differential effects of type 1 diabetes mellitus and subsequent osteoblastic β-catenin activation on trabecular and cortical bone in a mouse mode

  • Chen, Sixu;Liu, Daocheng;He, Sihao;Yang, Lei;Bao, Quanwei;Qin, Hao;Liu, Huayu;Zhao, Yufeng;Zong, Zhaowen
    • Experimental and Molecular Medicine
    • /
    • v.50 no.12
    • /
    • pp.3.1-3.14
    • /
    • 2018
  • Type 1 diabetes mellitus (T1DM) is a pathological condition associated with osteopenia. $WNT/{\beta}$-catenin signaling is implicated in this process. Trabecular and cortical bone respond differently to $WNT/{\beta}$-catenin signaling in healthy mice. We investigated whether this signaling has different effects on trabecular and cortical bone in T1DM. We first established a streptozotocin-induced T1DM mouse model and then constitutively activated ${\beta}$-catenin in osteoblasts in the setting of T1DM (T1-CA). The extent of bone loss was greater in trabecular bone than that in cortical bone in T1DM mice, and this difference was consistent with the reduction in the expression of ${\beta}$-catenin signaling in the two bone compartments. Further experiments demonstrated that in T1DM mice, trabecular bone showed lower levels of insulin-like growth factor-1 receptor (IGF-1R) than the levels in cortical bone, leading to lower $WNT/{\beta}$-catenin signaling activity through the inhibition of the IGF-1R/Akt/glycogen synthase kinase $3{\beta}$ ($GSK3{\beta}$) pathway. After ${\beta}$-catenin was activated in T1-CA mice, the bone mass and bone strength increased to substantially greater extents in trabecular bone than those in cortical bone. In addition, the cortical bone of the T1-CA mice displayed an unexpected increase in bone porosity, with increased bone resorption. The downregulated expression of WNT16 might be responsible for these cortical bone changes. In conclusion, we found that although the activation of $WNT/{\beta}$-catenin signaling increased the trabecular bone mass and bone strength in T1DM mice, it also increased the cortical bone porosity, impairing the bone strength. These findings should be considered in the future treatment of T1DM-related osteopenia.

Validity of Linear Combination Approach based on Net Damping Analysis of Cable-Damper System (케이블-댐퍼 시스템의 전체감쇠비 해석을 통한 선형조합 접근법의 유효성)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.467-475
    • /
    • 2009
  • Existing studies have suggested Universal Curve only for supplemental damping by damper. Therefore net damping has been determined by means of arithmetic summation between intrinsic, aero-damping of cable and supplemental damping of damper. However linear combination approach by means of the arithmetic summation is not enough theoretical background. So validity of this approach should be verified in order to design adequate cable-damper system by engineers. This study establishes governing differential equation which can consider intrinsic, aero-damping and supplemental damping as well. And also analysis method is solved by combination of muller method and successive iteration method. Consequently, this study succeeds in verification for validity of linear combination approach. As a result of this study, linear combination approach is limitedly effective in case of low stiffness and optimum damping coefficient of damper, short distance from support to damper, lower vibration mode, low aero-damping, and normal windy environment. Whereas this study will be effective in case of opposite conditions, and existing studies or linear combination approach occur to further error. Meaning of this study presents exact solution for net damping of cable-damper system, and verifies linear combination approach by means of the analysis method. In the future, if monitoring of optimum damping coefficient of a damper against aero-damping is feasible on time, algorithm of this study will be available for control of cable and semi-active damper system such as magneto-rheological damper.

Design of a Low-Power 8-bit 1-MS/s CMOS Asynchronous SAR ADC for Sensor Node Applications (센서 노드 응용을 위한 저전력 8비트 1MS/s CMOS 비동기 축차근사형 ADC 설계)

  • Jihun Son;Minseok Kim;Jimin Cheon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.454-464
    • /
    • 2023
  • This paper proposes a low-power 8-bit asynchronous SAR ADC with a sampling rate of 1 MS/s for sensor node applications. The ADC uses bootstrapped switches to improve linearity and applies a VCM-based CDAC switching technique to reduce the power consumption and area of the DAC. Conventional synchronous SAR ADCs that operate in synchronization with an external clock suffer from high power consumption due to the use of a clock faster than the sampling rate, which can be overcome by using an asynchronous SAR ADC structure that handles internal comparisons in an asynchronous manner. In addition, the SAR logic is designed using dynamic logic circuits to reduce the large digital power consumption that occurs in low resolution ADC designs. The proposed ADC was simulated in a 180-nm CMOS process, and at a 1.8 V supply voltage and a sampling rate of 1 MS/s, it consumed 46.06 𝜇W of power, achieved an SNDR of 49.76 dB and an ENOB of 7.9738 bits, and obtained a FoM of 183.2 fJ/conv-step. The simulated DNL and INL are +0.186/-0.157 LSB and +0.111/-0.169 LSB.

A Narrative Literature Review on the Neural Substrates of Cognitive Reserve: Focusing on the Resting-state Functional Magnetic Resonance Imaging Studies (인지예비능의 신경적 기질에 대한 서술적 문헌고찰 연구 : 휴지기 기능적 자기공명영상 연구를 중심으로)

  • Hyeonsang Shin;Woohyun Seong;Bo-in Kwon;Yeonju Woo;Joo-Hee Kim;Dong Hyuk Lee
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Cognitive reserve (CR) is a concept that can explain the discrepancies between the pathologic burden of the disease and clinical manifestations. It refers to the individual susceptibility to age-related brain changes and pathologies related to Alzheimer's disease, thus recognized as a factor affecting the trajectories of the disease. The purpose of this study was to explore the current states of clinical studies on neural substrates of CR in Alzheimer's disease using functional magnetic resonance imaging. We searched for clinical studies on CR using fMRI in the Pubmed, Cochrane library, RISS, KISS and ScienceON on August 14, 2023. Once the online search was finished, studies were selected manually by the inclusion criteria. Finally, we analyzed the characteristics of selected articles and reviewed the neural substrates of CR. Total thirty-four studies were included in this study. As surrogate markers of CR, not only education and occupational complexity, but also composite score and questionnaire-based method, which cover various areas of life, were mainly used. The most utilized methods in resting-state fMRI were independent component analysis, seed-based analysis, and graph theory analysis. Through the analysis, we demonstrated that neuroimaging techniques could capture the neural substrates associated with cognitive reserve. Moreover, functional connectivity of brain regions centered on prefrontal and parietal cortex and network areas such as default mode network showed a significant correlation with CR, which indicated a significant association with cognitive performance. CR may induce differential effects according to the disease status. We hope that this perspective on cognitive reserve would be helpful when conducting clinical researches on the mechanisms of traditional Korean medicine for Alzheimer's disease in the future.

Genetic Parameters of Pre-adjusted Body Weight Growth and Ultrasound Measures of Body Tissue Development in Three Seedstock Pig Breed Populations in Korea

  • Choy, Yun Ho;Mahboob, Alam;Cho, Chung Il;Choi, Jae Gwan;Choi, Im Soo;Choi, Tae Jeong;Cho, Kwang Hyun;Park, Byoung Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.12
    • /
    • pp.1696-1702
    • /
    • 2015
  • The objective of this study was to compare the effects of body weight growth adjustment methods on genetic parameters of body growth and tissue among three pig breeds. Data collected on 101,820 Landrace, 281,411 Yorkshire, and 78,068 Duroc pigs, born in Korean swine breeder farms since 2000, were analyzed. Records included body weights on test day and amplitude (A)-mode ultrasound carcass measures of backfat thickness (BF), eye muscle area (EMA), and retail cut percentage (RCP). Days to 90 kg body weight (DAYS90), through an adjustment of the age based on the body weight at the test day, were obtained. Ultrasound measures were also pre-adjusted (ABF, EMA, AEMA, ARCP) based on their test day measures. The (co)variance components were obtained with 3 multi-trait animal models using the REMLF90 software package. Model I included DAYS90 and ultrasound traits, whereas model II and III accounted DAYS90 and pre-adjusted ultrasound traits. Fixed factors were sex (sex) and contemporary groups (herd-year-month of birth) for all traits among the models. Additionally, model I and II considered a linear covariate of final weight on the ultrasound measure traits. Heritability ($h^2$) estimates for DAYS90, BF, EMA, and RCP ranged from 0.36 to 0.42, 0.34 to 0.43, 0.20 to 0.22, and 0.39 to 0.45, respectively, among the models. The $h^2$ estimates of DAYS90 from model II and III were also somewhat similar. The $h^2$ for ABF, AEMA, and ARCP were 0.35 to 0.44, 0.20 to 0.25, and 0.41 to 0.46, respectively. Our heritability estimates varied mostly among the breeds. The genetic correlations ($r_G$) were moderately negative between DAYS90 and BF (-0.29 to -0.38), and between DAYS90 and EMA (-0.16 to -0.26). BF had strong $r_G$ with RCP (-0.87 to -0.93). Moderately positive $r_G$ existed between DAYS90 and RCP (0.20 to 0.28) and between EMA and RCP (0.35 to 0.44) among the breeds. For DAYS90, model II and III, its correlations with ABF, AEMA, and ARCP were mostly low or negligible except the $r_G$ between DAYS90 and AEMA from model III (0.27 to 0.30). The $r_G$ between AEMA and ABF and between AEMA and ARCP were moderate but with negative and positive signs, respectively; also reflected influence of pre-adjustments. However, the $r_G$ between BF and RCP remained non-influential to trait pre-adjustments or covariable fits. Therefore, we conclude that ultrasound measures taken at a body weight of about 90 kg as the test final should be adjusted for body weight growth. Our adjustment formulas, particularly those for BF and EMA, should be revised further to accommodate the added variation due to different performance testing endpoints with regard to differential growth in body composition.

Cystic Fibrous Dysplasia in the Kong Bone (낭종성 섬유성 이형성증)

  • Bahk, Won-Jong;Rhee, Seung-Koo;Kang, Yong-Koo;Lee, An-Hi;Park, Jeong-Mi;Chung, Yang-Guk;Choi, Kwang-Cheon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2007
  • Purpose: We describe clinical, radiographic, MRI and pathologic findings as well as final outcome after simple curettage and bone graft of cystic fibrous dysplasia (FD) in the long bone, which has been rarely documented in the literature. Materials and Methods: Clinical records, radiographs, MRI and histologic slides of 11 patients with cystic FD in the long bone were retrospectively analyzed. Results: Six patients complained pain for several months, 4 patients presented pain after trivial injury event, and 1 patient suffered pathologic fracture. The mode of involvement was monostotic in 10 patients and polyostotic in l patient. The femur was affected in 7 patients, the humerus in 3, and the radius in 1. Radiography showed prominent, expansive lysis associated with ground-glass density of FD. MRI revealed 2 different signals of FD and cyst. Microscopic examination revealed classic findings of FD and non-specific cystic degeneration. The final outcome was satisfactory in every patient. Local recurrence was not observed. Conclusion: Cystic FD in the long bone seems not as rare as the scarcity of reported cases would indicate. MRI features provide a basis for differential diagnosis between benign cystic change and malignant transformation. Cystic FD would be an indication for surgery and simple curettage with allo-chip-bone graft is effective.

  • PDF