• Title/Summary/Keyword: Differential display

Search Result 244, Processing Time 0.458 seconds

PanelLink Digital Flat Panel Display Transmitter for TFT LCD Test (TFT LCD 검사용 패널링크 디지털 플랫 패널 디스플레이 송신부 구현)

  • Lee, Seon-Bok;Baek, Woon-Sung;Park, Chang-Soo;Hong, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.621-623
    • /
    • 1998
  • We implemented PanelLlnk digital flat panel display transmitter supporting SXGA($1280{\times}1024$) resolution. It can transmit data through 10m cable at XGA($1024{\times}768$) resolution and through 7m cable at SXGA($1280{\times}1024$). We also found resistor value to get stable display image by low voltage differential signal swing control.

  • PDF

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF

Mining of Biomarker Genes from Expressed Sequence Tags and Differential Display Reverse Transcriptase-Polymerase Chain Reaction in the Self-fertilizing Fish, Kryptolebias marmoratus and Their Expression Patterns in Response to Exposure to an Endocrine-disrupting Alkylphenol, Bisphenol A

  • Lee, Young-Mi;Rhee, Jae-Sung;Hwang, Dae-Sik;Kim, Il-Chan;Raisuddin, Sheikh;Lee, Jae-Seong
    • Molecules and Cells
    • /
    • v.23 no.3
    • /
    • pp.287-303
    • /
    • 2007
  • Expressed sequence tags (ESTs) and differentially expressed cDNAs from the self-fertilizing fish, Kryptolebias marmoratus were mined to develop alternative biomarkers for endocrine-disrupting chemicals (EDCs). 1,577 K. marmoratus cDNA clones were randomly sequenced from the 5'-end. These clones corresponded to 1,518 and 1,519 genes in medaka dbEST and zebrafish dbEST, respectively. Of the matched genes, 197 and 115 genes obtained Unigene IDs in medaka dbEST and zebrafish dbEST, respectively. Many of the annotated genes are potential biomarkers for environmental stresses. In a differential display reverse transcriptase-polymerase chain reaction (DD RT-PCR) study, 56 differential expressed genes were obtained from fish liver exposed to bisphenol A. Of these, 16 genes were identified after BLAST search to GenBank, and the annotated genes were mainly involved in catalytic activity and binding. The expression patterns of these 16 genes were validated by real-time RT-PCR of liver tissue from fish exposed to bisphenol A. Our findings suggest that expression of these 16 genes is modulated by endocrine disrupting chemicals, and therefore that they are potential biomarkers for environmental stress including EDCs exposure.

Human Sensitivity Responses to Vibrotactile Stimulation on the Hand : Measurement of Differential Thresholds (진동식 촉각 자극에 대한 손의 상대적 민감도 반응)

  • Lee, Seong-Il
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.1-12
    • /
    • 1999
  • This study investigated human operator's perceptual and psychophysical responses to vibrotactile stimulation on various parts of the hand. Using a small vibrotactile display, the effects of three mechanical parameters consisting vibrotactile stimulations, i.e., vibration frequency, pulse-width modulation duty cycle, and number of contactors, on differential thresholds were examined at five different loci of the hand. It was observed that differential threshold varies with vibration frequency and number of active contactors. Differential sensitivity was the greatest at the vibration frequency of 120 Hz. The differential sensitivity was not found to be affected by loci on the hand. The area of stimulation on the hand was also found to be significant in that the sensitivity increased with the number of active contactors. It should be noted that the conclusions from this study generally correspond to those from the previous study on the absolute sensitivity. which means that tactile sensitivity to vibrotactile stimulations can be controlled with a systematic and consistent passion for emulating normal everyday contact on human hands in teleoperation and virtual reality applications.

  • PDF

Analysis and Design Optimization of Interconnects for High-Speed LVDS Applications (고속 LVDS 응용을 위한 전송 접속 경로의 분석 및 설계 최적화)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.761-764
    • /
    • 2007
  • This paper addresses the analysis and the design optimization of differential interconnects for Low-Voltage Differential Signaling (LVDS) applications. Thanks to the differential transmission and the low voltage swing, LVDS offers high data rates and improved noise immunity with significantly reduced power consumption in data communications, high-resolution display, and flat panel display. We present an improved model and new equations to reduce impedance mismatch and signal degradation in cascaded interconnects using optimization of interconnect design parameters such as trace width, trace height and πace space in differential flexible printed circuit board (FPCB) transmission lines. We have carried out frequency-domain full-wave electromagnetic simulations, time-domain transient simulations, and S-parameter simulations to evaluate the high-frequency characteristics of the differential FPCB interconnects.

  • PDF

Optimization of Crystallization Condition for Transparent LAS Glass-ceramic Via Differential Thermal Analysis (DTA를 통한 LAS계 투명 결정화 유리의 결정화 조건 최적화)

  • Moon, Yun-Gon;Lim, Tae-Young;Lee, Mijai;Kim, Jin-Ho;Jeon, Dae-Woo;Hwang, Jonghee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.101-105
    • /
    • 2016
  • The basic characteristics of glass are highly fragile and brittle consequences the ultimate purpose of glass manufacturing is to make a transparent glass with complex shape. In order to solve this problem, mechanical properties of glass can be increased by crystallization of its amorphous glass. However, glass-ceramics has become opaque through crystallization process due to the distracted interface of glass by precipitated particles. This study has been investigated thermal processing conditions of LAS transparent glass-ceramic by using DTA (differential thermal analysis), in order to control size of precipitated particle and then fabricate transparent glass-ceramic. DTA indicated that crystallization peak area was declined with increased nucleation temperature. Subsequently, we have been established optimum temperature for crystallization depending on the nucleation temperature. The transmission and thermal expansion were measured after crystallization, and the size of precipitated particle was identified in range of 20~100 nm by FE-SEM. In addition, by setting the optimized crystallization condition, with high transmission and low thermal expansion glass was synthesized through this experiment.