• 제목/요약/키워드: Differential Relay

검색결과 94건 처리시간 0.021초

전압, 전류 변화 추이를 이용한 전력용 변압기 보호계전 알고리즘 (A New Protective Relaying Algorithm for Power Transformer Based on Three Phase Voltage and Current)

  • 김상태;이승재;강상희;진보건;윤상현;이태성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권4호
    • /
    • pp.157-165
    • /
    • 2001
  • The two criteria to identify the disturbances of the power transformer has been reported in this paper. They have been derived through EMTP simulations of internal faults, inrush and overexcitation for the model of 154/22.9[kV], 40[MVA], Y-Y three-phase power transformer. We propose the crisp algorithm which uses two criteria. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 7.2[ms]. The proposed algorithm immunes to the transient state.

  • PDF

Power allocation-Assisted secrecy analysis for NOMA enabled cooperative network under multiple eavesdroppers

  • Nayak, V. Narasimha;Gurrala, Kiran Kumar
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.758-768
    • /
    • 2021
  • In this work, the secrecy of a typical wireless cooperative dual-hop non-orthogonal multiple access (NOMA)-enabled decode-and-forward (DF) relay network is investigated with the impact of collaborative and non-collaborative eavesdropping. The system model consists of a source that broadcasts the multiplexed signal to two NOMA users via a DF relay, and information security against the eavesdropper nodes is provided by a helpful jammer. The performance metric is secrecy rate and ergodic secrecy capacity is approximated analytically. In addition, a differential evolution algorithm-based power allocation scheme is proposed to find the optimal power allocation factors for relay, jammer, and NOMA users by employing different jamming schemes. Furthermore, the secrecy rate analysis is validated at the NOMA users by adopting different jamming schemes such as without jamming (WJ) or conventional relaying, jamming (J), and with control jamming (CJ). Simulation results demonstrate the superiority of CJ over the J and WJ schemes. Finally, the proposed power allocation outperforms the fixed power allocation under all conditions considered in this work.

비접지 DC 급전계통에서 전류형 지락보호계전기의 사용 (New Ground Fault Protective Relay in DC Traction Power System)

  • 정상기;백남욱;김연수;이성혁;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1297-1302
    • /
    • 2004
  • In DC power distribution system for urban rail transits potential relay, 64P, is used to detect the ground faults. The problem with this 64P is that though it detects the ground fault it cannot identify the faulted region. Therefore the faulted region cannot be isolated properly. It could results in power loss of the trains on the healthy regions and the safety of the passengers in the trains could be affected adversely. A new ground fault protective relaying scheme that can identify the faulted region is presented in this paper. The new concept uses the current differential scheme and the permissive scheme to identify the faulted region correctly. A device with similar characteristic to the arrestor is adapted to use the current relay for the ground fault detection. The role of the device is to block the ground leakage current in normal operating condition and enable the ground fault current to flow in ground fault condition. The algorithm of the new relay and the effect of the newly adapted device in the new relaying scheme are discussed.

  • PDF

철도환경에서 혼합 중계 프로토콜을 이용한 협력 네트워크의 성능 (Performance of Cooperative Networks with Mixed Relaying Protocols in Railway Environments)

  • 조웅
    • 한국전자통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.271-276
    • /
    • 2016
  • 협력 네트워크는 여러 중계기를 통해서 수신되는 신호 및 직접파 신호를 결합하여 복조함으로써 전체 통신성능을 향상시킨다. 본 논문에서는 철도환경에서 혼합 중계 프로토콜을 이용하는 협력통신 시스템의 성능을 분석한다. 송신기와 수신기 사이에 여러 개의 중계기 사용을 가정하고, 각 중계기들은 하나의 정해진 중계 프로토콜이 아닌 복조 후 전송 혹은 증폭 후 전송 프로토콜을 이용하는 경우를 고려한다. 두 가지 중계 프로토콜이 존재하는 경우 각 중계 프로토콜이 전체 시스템의 성능에 미치는 영향을 분석하고 중계기 위치에 따른 성능에 대해서도 고려한다. 변조방식은 철도환경과 같은 빠른 채널변화에서도 채널상태정보의 이용 없이 신호의 복조가 가능한 차등변조 방식을 적용한다.

차전류 차분 방지 변압기 보호용 전류차동 계전방식 (A Difference-Blocked Current Differential Relaying Algorithm for Power Transformers)

  • 강용철;김대성;김은숙;원성호;이병은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.16-18
    • /
    • 2002
  • This paper proposes a difference-blocked current differential relaying algorithm for power transformers. The proposed algorithm observes that the shape of the differential current is changed using the difference. If the change is detected, output of current differential relay is blocked for a certain time. In this way, the algorithm distinguishes internal faults from magnetizing inrush. The proposed algorithm uses only currents and is unaffected by the remanent flux.

  • PDF

Fuzzy Logic Based Relaying Using Flux-differential Current Derivative Cure for Power Transformer Protection

  • 권명현;박철원;서희석;이복구;신명철
    • 한국지능시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.72-82
    • /
    • 1998
  • Power transformer protective relay should block the tripping during magnetizing imrush and rapidly operate the tripping during internal faults. But traditional approaches maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmounic component. To enhance the fault detection sensitivities of conventional technuques, flux-differential current derivative curve by fuzzy theory approaches is used. This paper deals with fuzzy logic based protective relaying for power transformer. The proposed fuzzy based relaying algorithm consisits of flux-differential current derivative curve, harmonics restraint, and precentage differential characteristic curv. The proposed relaying was tested with relaying signals obtained from Salford EMTP simulation package and showed a fast and accurate trip operation.

  • PDF

Agent 기반 변압기의 Sympathetic inrush 판단 방법 (Agent based algorithm for detecting sympathetic inrush of a transformer)

  • 강용철;이병은;박종민;황태근;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.234-235
    • /
    • 2006
  • The protection relay keeps electric power facilities by using signals of the voltage and current which are input and output terminals of each equipment. Each relay performances protection algorithm by using informations of own protecting zone. To prevent the mal-operation in inrush current, established transformer differential protection method uses the second harmonics as blocking signal. This method is not operate at the initial inrush. However, in case of the parallel operation, if the initial inrush is occurred in one transformer which is generated, the sympathetic inrush Is occurred in adjacent transformer. This paper approach the sympathetic inrush detecting algorithm of a transformer based on agent. Proposed algorithm, when inrush current occurred, distinguish sympathetic inrush or not by using differential current of adjacent transformer. This algorithm have the advantage of the distinguishing initial inrush and sympathetic inrush at operation of parallel transformer

  • PDF

On the Performance of Incremental Opportunistic Relaying with Differential Modulation over Rayleigh Fading Channels

  • 보 웬 옥 바오;공형윤
    • 한국통신학회논문지
    • /
    • 제35권7A호
    • /
    • pp.731-742
    • /
    • 2010
  • We propose an incremental relaying protocol in conjunction with opportunistic communication for differential modulation with an aim to make efficient use of the degrees of freedom of the channels by exploiting a imited feedback signal from the destination. In particular, whenever the direct link from the source to the destination is not favorable to decoding, the destination will request the help from the opportunistic relay (if any). The performance of the proposed system is derived in terms of average bit error probability and achievable spectral efficiency. The analytic results show that the system assisted by the opportunistic relaying can achieve full diversity at low SNR regime and exhibits a 30㏈ gain relative to direct transmission, assuming single-antenna terminals. We also determine the effect of power allocation on the bit error probability BEP) performance of our relaying scheme. We conclude with a discussion on the relationship between the given thresholds and channel resource savings. Monte-Carlo simulations are performed to verify the analysis.

비율차동특성을 이용한 변압기의 실시간 디지탈보호 (A real -time digital protection for transformer using percentage differential characteristic)

  • 서희석;신명철;윤만철;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.63-66
    • /
    • 1992
  • This paper presents the real time digital differential protection scheme for transformer. Inrush and Internal fault conditions are distinguished by the relative magnitudes of fundamental and second harmonic components which are extracted from differential currents. The algorithm is simulated and implemented using a prototype relay which is made up of Intel 80286 CPU and Motorola DSP-56001. The testing data of inrush and Internal fault signals which are sampled at a rate of 12 times a cycle are obtained by EMTP, and tested In real time using simulator which downloaded those data.

  • PDF

뉴로-퍼지를 이용한 변기 보호 알고리즘 (Protective Algorithm for Transformer Using Nuro-Fuzzy)

  • 이명윤;이종범;홍동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.299-302
    • /
    • 2002
  • The second harmonic component is commonly used for blocking differential relay in Power transformers. However it is difficult to distinguish between inrush and internal winding fault with differential current protective relaying. This paper proposed a new method using nuro-fuzzy. The used data in nuro-fuzzy algorithm are 3-phase primary voltage and fundamental harmonic of differential current. Various states of transformer are simulated using BCTRAN and HYSDAT of EMTP. As a result of applying the algorithm in various cases, the correct discrimination between internal winding fault and inrush performed.