  • Protective relay for transformer operates in general by comparing with the differential current and the restraint current. These kinds of currents are changed on magnitude and phasor during the fault according to winding type and vector group. This paper presents the differential and restraint currents and operational principle of differential protective relay for two-winding and three-winding transformer with graphical model. It is developed using MATLAB for an educational purpose on engineer related in power system and protection in university and power utility including large factory.

  • PDF

유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구 (A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage)

  • 정성교;이재경;김한도;최대길;강용철;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

변조방식 및 중계기 위치를 고려한 차등 분산 협력 네트워크의 성능비교 (Performance Comparison of Differential Distributed Cooperative Networks with Modulation Scheme and Relay Location)

  • 조웅
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.445-450
    • /
    • 2020
  • 협력 네트워크는 전송기에서 송신기로 신호를 전송할 때 여러 개의 중계기를 통해 신호를 전송함으로써 통신성능을 향상시키고 전송용량을 증가시키는 장점을 제공한다. 본 논문에서는 송신기와 중계기 사이에서는 일반적인 이진변조방식을 이용하여 신호를 전송하고 중계기와 수신기 사이에서는 차등 공간 시간 코드 방식을 적용한 신호전송 시스템을 고려한다. 먼저 송신기와 중계기 사이에서 동기방식과 차등변조 방식을 적용했을 때의 성능을 분석한다. 변조방식 및 중계기의 개수를 고려한 다양한 중계기 위치에서의 성능 또한 비교한다.

오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰 (Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio)

  • 배영준;이승재;최면송;강상희;김상태;최정이;정창현;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF

Secure Transmission for Two-Way Vehicle-to-Vehicle Networks with an Untrusted Relay

  • Gao, Zhenzhen
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권6호
    • /
    • pp.443-449
    • /
    • 2015
  • This paper considers the physical layer security problem for a two-way vehicle-to-vehicle network, where the two source vehicles can only exchange information through an untrusted relay vehicle. The relay vehicle helps the two-way transmission but also acts as a potential eavesdropper. Each vehicle has a random velocity. By exploiting the random carrier frequency offsets (CFOs) caused by random motions, a secure double-differential two-way relay scheme is proposed. While achieving successful two-way transmission for the source vehicles, the proposed scheme guarantees a high decoding error floor at the untrusted relay vehicle. Average symbol error rate (SER) performance for the source vehicles and the untrusted relay vehicle is analyzed. Simulation results are provided to verify the proposed scheme.

Modified Differential Protection for Transformers in Wind Farms

  • George, Sujo P.;Ashok, S
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.78-88
    • /
    • 2018
  • The liberalization of electricity market and environmental concerns are the major driving forces for the development of Distributed Generation (DG). The mode of grid-connected wind power generation is becoming popular and has matured as a reliable DG technology. The voltage generated by the wind generator is stepped up to the higher voltage by the transformers before connecting to the grid. Operating algorithm of the differential relays for transformer protection used in the wind farms need to be modified to take care of the dynamic nature of fault current caused by the intermittent nature of the wind power. An algorithm for the differential relay is proposed in which dual slope characteristics are adjusted with varying fault level situation according to the wind generator in service as well as with the wind speed. A case study conducted for a typical wind farm shows that the proposed method avoids mal-operation of the differential relay in varying wind power conditions.

154 kV 변압기 보호용 비율차동계전기 오동작 방지를 위한 2고조파 억제 방식의 적용방법 및 정정값에 관한 연구 (A Study on the 2nd Harmonic Blocking Scheme and Setting Value of a Current Differential Relay for 154 kV Transformers to Prevent Maloperation)

  • 손용범;강상희
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.29-37
    • /
    • 2018
  • Inrush current and fault current in a transformer need to be distinguished from one another. In order to do this, KEPCO uses a 2nd harmonic restraint/block method. We use two setting values for 2nd harmonic restraint; 15% and 10%. We also apply per-phase blocking method among various harmonic restraint methods. If the transformer is located at the radial system, we adjust 10% in the 2nd harmonic restraint, but this method is not enough to prevent mal-operations of the current differential relay and let us spend more time to change setting value again as the power system changes. In this paper, a more reasonable setting value for a 2nd harmonic blocking scheme in KEPCO is proposed. To present a proposed method, the fault data of the current differential relays which have occurred since 2009 are analyzed. To evaluate the performance of the proposed method, the results of the RTDS test for the current differential relay of the transformer by KEPCO are analyzed.

철도환경에서 에너지 할당에 따른 부분차등변조 방식을 이용한 중계 네트워크의 성능 (Performance of Relay Networks with Partially Differential Modulation Scheme Depending on Energy Allocation in Railway Environments)

  • 조웅;조한벽
    • 한국전자통신학회논문지
    • /
    • 제11권1호
    • /
    • pp.17-22
    • /
    • 2016
  • 중계 네트워크에서는 중계기를 이용하여 송신기로 수신된 신호를 증폭 혹은 복조 후 재변조하여 수신기로 전송하는 역할을 수행한다. 수신기에서는 여러 중계기로부터 수신된 신호를 결합하여 신호를 복조함으로써 통신 성능을 향상 시킬 수 있다. 본 논문에서는 철도환경에서 에너지 할당에 따른 중계 네트워크의 성능을 분석한다. 변조방식은 중계기에서는 동기방식을 사용하고 수신기에서는 비동기 방식을 사용하는 부분차등변조 방식을 적용한다. 중계 네트워크에서 주어진 전체 에너지에 대해 수신기와 중계기의 다양한 에너지 할당에 따른 성능을 분석한다.

모선보호용 디지털계전기의 고장분석 프로그램의 구현 (A Fault Analysis Program for a Digital Bus Protection Relay)

  • 손천명;강상희;이승재;안용진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.246-248
    • /
    • 2001
  • In this paper, the fault analysis program that is convenient to analyse fault records of a digital relay and to set a digital relay is described. The key feature of this fault analysis program is as follows. - analysing fault records stored in a local PC and/or a digital relay - analysing events - setting a digital relay. This program is for a digital bus protection relay using a conventional variable percentage current differential relaying algorithm. So this program adds a function analysing the characteristic of each variable percentage current differential function and the connection state of the transmission lines at double-bus system.

  • PDF

80C196KC를 이용한 변압기 보호 계전기 (Ratio Differential Relay Using 80C196KC Microprocessor for Transformer Protection)

  • 황용연;최창영;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.505-506
    • /
    • 2007
  • A ratio differential relay using 80C196KC microprocessor was developed in this paper. The internal faults, external faults and inrush were simulated by EMTP. The performance of developed relay was verified with software and hardware simulation.