• 제목/요약/키워드: Differential Pulse Voltammetry

검색결과 121건 처리시간 0.026초

Acetonitrile 용액중(溶液中)에서 0,0-Dimethyl-0-(3-Methyl-4-Nitrophenyl)-phosphorothioate(Sumithion®)의 전기화학적(電氣化學的) 환원반응(還元反應) (Electrochemical Reduction of 0,0-Dimethyl-0-(3-Methyl-4-Nitrophenyl)-phosphorothioate(Sumithion®) in Acetonitrile Solution)

  • 박승희;성낙도
    • 농업과학연구
    • /
    • 제11권2호
    • /
    • pp.315-321
    • /
    • 1984
  • 0.1M tetraethylammoniumperchlorate (TEAP)를 지지전해질로 한 acetonitrile속에서 direct current (DC), differential pulse (DP) polarography 및 cyclo voltammetry (CV) 방법에 의한 Sumithion의 전기화학적 환원반응은 -1.0~-2.50volt vs. Ag-AgCl 범위에서, 제1단계로 P-Oph 결합의 분열에 의하여 dimethylthiophosphonyl radical과 p-nitro-m-cresol이 생성되는 1전자 유사가역반응이 일어나고, 제2단계는 전형적인 1전자 비가역 반응으로 dimethylthiophosphonyl radical이 dimethylthiophosphonate가 되며, 제3단계 반응은 2.7volt vs. Ag-AgCl의 높은 음전위에서 p-nitro-m-cresol은 4전자 비가역반응에 의한 nitro group의 환원으로 p-hydroxy-amino-m-cresol이 생성되는 총 3단계의 비가역적인 electron-transfer chemical reaction (EC) 메카니즘으로 전극반응이 진행됨을 알았다.

  • PDF

Anodic Stripping Differential Pulse Voltammetric Determination of Trace Amounts of Lead after Preconcentration of Its Complex with 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol onto Natural Analcime Zeolite by Column Method

  • Taher, Mohammad Ali;Mostafavi, Ali;Afzali, Darush;Rezaeipour, Ebrahim
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권8호
    • /
    • pp.1125-1129
    • /
    • 2004
  • This work assesses the potential of natural Analcime Zeolite as an adsorbent for preconcentration of lead (II) traces. Lead is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol by column method with Analcime in the pH range of 5-6.5 and 2 mL $min^{?1}$ flow rate. Lead was removed from the column with 10.0 mL of 4 M hydrochloric acid and was determined by anodic stripping differential pulse voltammetry. 0.5ppb detection limit was obtained and linear dynamic range was 3 to $1.2{\times}10^5$ ppb in final solution with correlation coefficient of 0.999 and relative standard deviation of ${\pm}$ 1.2% (for eight replicate determination of 2.5 ${\mu}g\;mL^{?1}$ of lead). Various parameters such as the effect of pH, flow rate, instrumental conditions and interferences of some ions on the determination of lead have been studied in detail for optimization of conditions. The method was successfully applied for determination of lead in various samples.

3-Phenyl-4-Nitrosydnone의 전기화학적 연구 (Electrochemical Study on the 3-Phenyl-4-Nitrosydnone)

  • 김일광;김윤근;한순종
    • 대한화학회지
    • /
    • 제32권3호
    • /
    • pp.195-202
    • /
    • 1988
  • Acetonitrile 용액중에서 3-phenyl-4-nitrosydnone의 전기화학전 환원을 direct current, differential pulse polarography, cyclic voltammetry 그리고 controlled potential coulometry 방법으로 연구하였다. Phenyl-N 단일 결합의 분리 이전에 nitro 기능기의 비가역적 전자 전달-화학반응(EC)기구의 진행으로 다전자 이동에 의한 amino(또한 hydroxylamino)기를 형성하고, 높은 음 전위 영역에서 2,3 비가역성 환원파의 일전자전달-화학반응에 의한 phenyl hydrazine을 생성하였다. 음극 반파 전위들은 cetyltrimethyl ammonium bromide의 억제 효과에 의해 음의 값으로 이동하였고 한편, sodium lauryl sulfate micelle은 높은 음전위 영역에서 제 2,3 환원파의 가역성산화 peaks를 보였다.

  • PDF

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권11호
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

내피온-에틸렌디아민이 수식된 유리탄소전극으로 구리(II) 이온의 정량 (Determination of Copper(II) ion with a nafion-ethylenediamine modified glassy carbon electrode)

  • 고영춘;김희철
    • 분석과학
    • /
    • 제20권3호
    • /
    • pp.213-218
    • /
    • 2007
  • Perfluorinated sulfonated polymer-ethylenediamine(nafion-en)이 수식된 유리탄소전극을 이용하여 Cu(II) 이온을 정량하였다. 이 수식전극의 en은 Cu(II) 이온과 $[Cu(en)_2]^{+2}$의 착물을 형성한다. Nafion-en이 수식된 유리탄소전극에서 시차펄스전압전류법에 의한 Cu(II) 이온의 환원봉우리전위는 -0.4402V(${\pm}0.0050V$) (vs. Ag/AgCl)에서 측정되었고, 측정범위는 $1.0{\times}10^{-6}{\sim}1.0{\times}10^{-4}M$, 검출한계(3s)는 $1.96{\times}10^{-6}M$이었다.

Determination of Higenamine in the Commercial Aconiti Tuber and Its Pharmaceutical Preparations

  • Hahn, Young-Hee;Cheong, Kyo-Soon;Paik, Seung-Whan;YunChoi, Hye-Sook
    • 생약학회지
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 1986
  • A cardiac principle of Aconiti tuber, higenamine was analyzed with a differential pluse voltammetry employing a glassy carbon electrode. The peak potentials for the oxidation of higenamine were varied depending on the pH of the media. Higenamine at the concentration of $5.4{\times}10^{-7}M$ (0.146ppm) was easily determined using a pH 7.0 phosphate buffer. The amounts of higenamine in the crude Aconiti tuber and tablets containing A. tuber were determined by a standard addition method after extracting with methanol, partitioning with a mixture of $H_2O$ and $CHCl_3$, and freeze-drying the aqueous layer.

  • PDF

Nafion-ethylenediamine이 수식된 유리탄소전극에 의한 시차펄스전압전류법으로 철(II) 이온의 정량 (Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode)

  • 김경원;김희철;김성현;박병호;김연희;김경남;고영춘
    • 대한화학회지
    • /
    • 제47권2호
    • /
    • pp.115-120
    • /
    • 2003
  • Perfluorinated sulfonated polymer(Nafion)-ethylenediamine(en)이 화학수식된 유리탄소전극으로 Fe(II) 이온의 정량에 대해 연구하였다. Fe(II) 이온의 착화제인 en을 nafion에 고정시켜 유리탄소전극 표면에 수식하면 이 수식전극의 en은 Fe(II) 이온과 $[Fe(en)_3]^{+2}$의 착물을 형성한다. Nafion-en이 화학수식된 유리탄소전극에서 시차펄스전압전류법에 의한 Fe(II) 이온의 산화봉우리전위는 0.340${\pm}$0.015 V(vs. Ag/AgCl), 측정범위는 $5{\times}10^{-6}{\sim}0.2{\times}10^{-3} M(0.28{\sim}11.17 mg/L)$, 검출한계(3s)는 $1.89{\times}10^{-5}$M(1.056 mg/L)이었다.

Nano composite System based on ZnO-functionalized Graphene Oxide Nanosheets for Determination of Cabergoline

  • Beitollahi, Hadi;Tajik, Somayeh;Alizadeh, Reza
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.307-313
    • /
    • 2017
  • In this paper we report an electrochemical sensor based on ZnO-functionalized graphene oxide nanocomposite (ZnO-GO) for the sensitive determination of the cabergoline. Cabergoline electrochemical behaviors were investigated by cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV). The modified electrode shows electrocatalytic activity toward cabergoline oxidation in phosphate buffer solution (PBS) (pH 7.0) with a reduction of the overpotential of about 180 mV and an increase in peak current. The DPV data showed that the obtained anodic peak currents were linearly dependent on the cabergoline concentrations in the range of $1.0-200.0{\mu}M$, with the detection limit of $0.45{\mu}M$. The prepared electrode was successfully applied for the determination of cabergoline in real samples.

Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry

  • Attar, Tarik;Harek, Yahia;Larabi, Lahcen
    • 대한화학회지
    • /
    • 제57권5호
    • /
    • pp.568-573
    • /
    • 2013
  • A selective and sensitive method for simultaneous determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The procedure involves an adsorptive accumulation of Cu(II)-ETSC (4- ethyl-3-thiosemicarbazide) on a hanging mercury drop electrode, followed by a stripping voltammetry measurement of reduction current of adsorbed complex at about -715 mV. The optimum conditions for the analysis of copper (II) ion are : pH 10.3, concentration of 4-ethyl-3-thiosemicarbazide $3.25{\times}10^{-6}$ M and an accumulation potential of -100 mV. The peak current is proportional to the concentration of copper over the range 0.003-125 ng/mL with a detection limit of 0.001 ng/mL and an accumulation time of 60 s. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods of adsorptive stripping voltammetry for the determination of copper. The developed method was validated by analysis of whole blood certified reference materials.

Electrochemical Behavior and Differential Pulse Polarographic Determination of Rifampicin in the Pharmaceutical Preparations

  • Hahn, Young-Hee;Shin, Sun-Mi
    • Archives of Pharmacal Research
    • /
    • 제24권2호
    • /
    • pp.100-104
    • /
    • 2001
  • Differential pulse polarographic(DPP) analytical procedure for the rifampicin antibiotic, which can be applied to monitor its synthetic process from the starting antibiotic of rifamycin B or rifamycin SV has been developed based on the electrochemical reduction of an azomethine group. Rifampicin exhibited a cathodic peak due to the azomethine group in the side chain of 3-[(4-methyl-1-piperazinyl)imino]methyl moiety and another cathodic peak due to the carbonyl group in rifamycin SV by DPP. The experimental peak potential shift of an azomethine reduction was -73 mV/pH in the pH range between 3.0 and 7.5, agreeing with involvement of 4 e-and 5 $H^5$ in its reduction. By the cyclic voltammetric(CV) studies, the azomethine and the carbonyl reductions in rifampicin were processed irreversibly on the mercury electrode. The plot of peak currents vs. concentrations of rifampicin ranging $1.0{\times}10^{-7} M~$1.0{\times}10^{-5} M yielded a straight line with a correlation coefficient of 0.9996. The detection limit was $1.0{\times}10^{-8} M with a modulation amplitude of 50 mV DPP has been successfully applied for the determination of rifampicin in the pharmaceutical preparations.

  • PDF