• 제목/요약/키워드: Differential Modulation

검색결과 200건 처리시간 0.021초

N-methyl-D-aspartate 수용기의 다양한 조절이 일차 배양된 정상사람구강각화세포의 증식에 미치는 영향; DNA 합성율 평가 (THE EFFECT OF DIFFERENTIAL MODULATION OF N-METHYL-D-ASPARTATE RECEPTOR ON THE PROLIFERATION OF PRIMARY CULTURED NORMAL HUMAN ORAL KERATINOCYTES: DNA SYNTHESIS RATE ANALYSIS)

  • 김인수;백기석;장미숙;이원;이승표
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권2호
    • /
    • pp.124-130
    • /
    • 2007
  • In the present study, I investigated the effects of N-methyl-D-aspartate (NMDA), arachidonic acid (AA), and Nitric Oxide Synthase Inhibitor (NOSI), alone or in combination, on the proliferation of cultured primary normal human oral keratinocytes (NHOK). The purpose of this study was therefore the preliminary study for the examination of the interaction between these agents and NHOK in order to elucidate the mechanisms by which epithelial growth and regeneration are regulated. NHOK were obtained from gingival tissue of 20 individuals aged 20 to 29, and third passage (P3) cells were used for this study. The DNA synthesis was measured by the BrdU assay. Addition of low concentration of AA ($1{\mu}M$) and high concentration of AA with NMDA group (NMDA+AA $10{\mu}M$) made DNA synthesis rate increase significantly at the early stage. Adding NNA ($10{\mu}M$) affected DNA synthesis rate to increase significantly in 4 hours. At the early stage, DNA synthesis was significantly active in the NOS-I with NMDA groups than in the control and the NMDA-only group, while it didn't become statistically meaningful in 24 hours. AA $1{\mu}M$ and NNA $10{\mu}M$ may induce the proliferation of the NHOK independently and NOS-I may induce the proliferation of the NHOK with NMDA. These reactions might be related to the NMDA receptor in the cell and the change of the intracellular calcium ion concentration.

항암제 다제내성(MDR) 암세포의 Hsp90 저해제 BIIB021에 대한 감수성의 차이 및 NSAIDs 및 Niclosamide에 의한 Hsp90 저해제의 활성 변화 (Differential Sensitivities of Human Multidrug-resistant Cancer Cells to BIIB021 and Modulation of Hsp90 Inhibitors by NSAIDs and Niclosamide)

  • 문현정;이수훈;김선희;강치덕
    • 생명과학회지
    • /
    • 제28권10호
    • /
    • pp.1212-1219
    • /
    • 2018
  • 열 충격 단백질인 heat shock protein 90 (Hsp90)은 종양 형성 과정에서 중요한 역할을 하고 있으며, 이에 따라 1세대 및 2세대 Hsp90저해제들이 개발되어, 다양한 암에서의 항암 효과가 보고되어 있다. 2세대 Hsp90저해제로 개발된 BIIB021는 1세대 Hsp90저해제인 17-allylamino-17-demethoxygeldanamycin (17-AAG)에 내성을 나타내는 항암제 다제내성(MDR) 암세포에 감수성을 가진다고 알려져 있지만, 본 연구에서 BIIB021에 내성인 MDR세포로서, MCF7-MDR 및 HeyA8-MDR세포가 해당됨을 밝혔다. BIIB021 감수성을 증강시키는 물질로 비스테로이드성 항염증약물(NSAID)인 dimethyl-celecoxib (DMC)의 BIIB021의 효과 증강 활성을 BIIB021-내성 및 -감수성 MDR 세포에서 확인하였다. MDR세포에 NSAID와 BIIB021의 병합 처리한 경우, NSAID의 자가분해(autophagy) 유도 활성에 의해 MDR세포에서 과잉 발현하는 변이형 mutant p53 (mutp53)을 분해할 뿐만 아니라 BIIB021 처리로 유도되는 Hsp70 발현을 억제하므로써, 암세포의 BIIB021 내성을 극복할 수 있는 활성을 나타내었다. 또한 NSAID 물질인 sulindac sulfate 및 FDA 승인 약물인 niclosamide 도 자가분해 유도 활성으로 Hsp90의 타켓 단백질 인 mutp53 및 c-Myc의 분해를 유도하므로서, 17-AAG 효과를 증강시켰다. 그러므로 본 연구에서는 새로운 BIIB021에 대한 효과 증강 및 내성 극복 물질로서, NSAIDs 및 niclosamide를 발굴하였으며, 이들 물질의 자가분해 경로 활성화에 의하여, BIIB021 효과를 극대화 시킴을 밝혔다.

Camptothecin 에 의한 ST1571 의 항암 활성 증강 (Synergistic antitumor activity of ST1571 and camptothecin in human cancer cells)

  • 김미주;이상민;배재호;정병선;강치덕;김선희
    • 생명과학회지
    • /
    • 제17권6호통권86호
    • /
    • pp.748-755
    • /
    • 2007
  • 본 연구에서는 전이성 암세포와 항암제 다제내성 세포에 있어서 항암제 내성에 영향을 미치는 것으로 알려진 DNA-dependent protein kinase (DNA-PK) 가 Abl protein-tyrosine kinases저해제인 STl571 내성에도 연관되어 있는지에 대하여 조사하였다. 또한 STl571 과 topoisomerase I 저해제인 camptothecin (CPT) 의 단독 및 병용처리에 의한 항암 활성을 전이성 암세포와 항암제 다제내성 세포를 대상으로 조사하였다. 세포의 전이도와 내성정도에 따라 STl571 의 감수성이 다르게 나타났다. 이와 함께 ST1571의 처리후 농도에 따라 전이도가 낮은 KMl2, PC3 세포와 항암제 감수성인 CEM, MCF-7 세포에서는 DNA-PK 의 발현이 감소하는 반면, 전이도가 높은 KML4a, PC-MM2 세포와 다제내성 CEM/MDR 및 MCR/MDR 세포에서는 그 발현이 증가되어 있음을 알 수 있었다. 이는 DNA-PK 의 발현이 STl571 의 내성에 관여한다는 것을 시사한다. 이와 같은 결과에 근거하여 DNA-PK 의 발현을 감소시키는 CPT를 STl571 내성을 나타내는 암세포에 대하여 STl571 과 병용처리 하였다. 그 결과 DNA-PK의 발현이 감소되고 세포증식이 억제됨으로써 ST1571 의 감수성이 CPT에 의해 증가하는 것을 알 수 있었다. 따라서 본 연구에서는 DNA-PK가 STl571 의 내성을 극복하는데 있어서 새로운 표적이 될 수 있으며, STl571 의 치료내성 극복에 CPT 와의 병용처리가 유효함을 알 수 있었다.

주파수 선택성 페이딩 환경하에서 $\frac{\pi}{4}$ shift QPSK 변조방식에 대한 다중파의 시간지역 검출법 제안 (A Multipath Delay Time Detection Method For $\frac{\pi}{4}$ Shift QPSK Modulation Under The Frequency Selective Fading Environment)

  • 조병진;김대영
    • 한국통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.941-950
    • /
    • 1991
  • 디지털 이동통신 전송로에 있어서 고속통신을 위한 시스템의 성능은 다중파 지연분산에 의해 크게 좌우된다. 본 논문에서는 최근 디지털 자동차 전화의 변복조방식으로 채택된 $\pi/4$ shift QPSK에 대해, 간이 다중파 지연시간 검출방법으로써 직교채널간섭량 (CCI)을 이용하는 방법을 제안하였다. $\pi/4$ shift QPSK신호는 원래 직교 채널에 정보를 갖고있기 때문에 BPSK변조방식처럼 Quadrature채널에서 간섭량을 얻기 위하여 주파수 체배기와 지연전파 방식을 제안하였다. 또한 다중파 전파환경하에서, 격렬하게 변하는 직교채널 간섭량으로 부터 정보를 얻는 방법으로서 절대치평균과 실효치 평균을 취하는 방법을 제안하였으며, 아울러 자연분산과 직교채널 간섭량과의 관계도 조사하였다. 이론적인 결과를 확인하기 위하여, 준정적인 2파 모델과 Rayleigh분포 2파모델하에서 computer simulation을 수행하였다. simulation결과 좋은 결과가 얻어졌으나. 본방식은 송신 대역제한에 어느정도 민감하다는 것이 밝혀졌다. 또한 H/W실현시 주요부분인 주파수 체배기에 대한 H/W구성 방안도 제안하였다.

  • PDF

한국인과 한국에 거주하는 외국인간의 타인종 얼굴에 대한 ERP 요소의 흥분성 조절 비교 (Up-regulation of an ERP component toward racial-outgroup faces in Koreans but not in non-Korean visitors)

  • 김혁;이강희;김현택;최준식
    • 인지과학
    • /
    • 제33권2호
    • /
    • pp.95-107
    • /
    • 2022
  • 다른 인종의 얼굴 인식에 대한 연구는 지각, 정서, 사회문화적인 과정 등 다양한 수준에서 연구되어 왔다. 특히, "다른 인종 효과(other race effect, ORE)"와 관련된 많은 수의 연구들에서, 신원이나 정서와 같은 얼굴에 대한 미묘한 정보가 처리되는 과정에서 '다른 인종'이라는 인종적인 요소가 영향을 주는 것으로 나타났다. 하지만 인종적인 요소가 아닌, 다른 인종의 얼굴에 대한 인지적인 조절로 ORE를 설명하려는 연구는 거의 없다. 본 연구는 다른 인종의 얼굴을 처리함에 있어서 생소하기(낯설기) 때문에 나타날 수 있는 인지적인 작용 여부를 사건관련전위(event-related potential, ERP)를 이용하여 연구하였다. 22명의 한국인과 9명의 백인에게 한국인과 백인의 정서가 표현된 얼굴사진을 보여주면서 성별 분류과제를 수행하였다. 한국인의 경우 백인의 얼굴 사진에 대하여 한국인의 얼굴 사진보다 더 증가된 P3 전위 값을 보였고, 이러한 결과는 한국인들이 자극 인식 초기 과정에서 다른 인종의 얼굴 사진에 대하여 더욱 주의를 기울인 것으로 해석할 수 있다. 흥미롭게도, 백인들은 한국인의 얼굴 사진을 보았을 때 증가된 P3 전위 값을 보이지 않았는데, 아마도 실험에 참여한 백인들의 경우 한국에서 생활을 하면서 많은 사회적인 상호작용을 통하여 한국인 얼굴에 대하여 탈민감화 되어 한국인의 얼굴이 더 이상 생소하지 않기 때문인 것으로 생각된다. 이러한 결과는 다른 인종의 얼굴은 자동적으로 주의를 끌어당기는 높은 각성수준을 갖는 현저한 자극이지만, 반복적인 노출만으로도 탈민감화 되어 타인종의 얼굴에 대한 각성수준이 낮아질 수 있다는 것을 의미한다.

선택적 Cyclooxygenase-2 억제제인 Celecoxib가 상이한 Cyclooxygenase-2 발현량을 가진 인간 암세포주들에 대하여 유도하는 방사선 감수성 증진 작용 (The Enhancement of Radiosensitivity by Celecoxib, Selective Cyclooxygenase-2 Inhibitor, on Human Cancer Cells Expressing Differential Levels of Cyclooxygenase-2)

  • 표홍렬;신유근;김현석;성진실;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제21권3호
    • /
    • pp.216-221
    • /
    • 2003
  • 목적: Cyclooxygenase-2 (COX-2)를 과발현하는 A549 인간폐암세포주와 발현하지 않는 MCF-7 인간유방암세포주에서 선택적 COX-2 억제제인 celecoxib의 방사선 감수성 증진 작용을 관찰하고자 하였다. 대상 및 방법: A549 세포와 MCF-7 세포에 대해서 방사선 혹은 방사선과 celecoxib를 병용 투여한 후에 clonogenic radiation survival 실험을 시행하였다. 같은 실험을 각각 $10\%$$1\%$의 FBS를 포함한 배지에서 반복하였다. 각 세포에 방사선과 celecoxib를 동시 혹은 단독 투여한 후에 각 실험 그룹의 세포사멸을 측정하였다. 결과: 약물 투여 기간 동안 $10\%$의 혈청을 포함한 배지 조건에서 배양된 A549세포에서는, $30\muM$$50\muM$ 농도의 celecoxib가 투여된 상태에서 surviving fraction=0.1에서의 Radiation enhancement ratio (RER)가 각각 1.58과 1.81로 celecoxib가 A549 세포의 방사선 감수성을 증가시켰다. 이러한 방사선 감수성의 증가는 세포를 $1\%$의 혈청을 포함한 배지에서 배양하였을때는 소실되었다. MCF-7 세포에서는 $10\%$$1\%$ 혈청을 포함한 각각의 배지조건 하에서celecoxib에 의한 방사선 감수성의 변화가 관찰되지 않았다. A549와 MCF-7 세포의 각 그룹에서 세포사멸을 측정한 결과 celecoxib와 방사선이 병용 투여되었을 때 유도되는 세포사멸은 상호 상승적이지 않은 것으로 나타났다. 결론: COX-2 선택적 억제제인 celecoxib는 COX-2를 과발현하는 A549 세포에서 선택적으로 방사선 감수성을 증진시켰으며, 저농도의 혈청을 포함한 배지 조건에서는 이러한 효과가 소실되었다. COX-2를 발현하지 않는 MCF-7 세포주에서는 celecoxib에 의해서 방사선 감수성이 변화되지 않았으며, 이러한 celecoxib의 방사선 감수성 증진 작용 기전에 세포 사멸은 관여하지 않는 것으로 보인다.

$M_1$$M_2$ 무스카린성 수용체에서 아미노산 Triplet Repeat의 Site-Mutagenesis가 수용체기능에 미치는 영향 (Effects of Site-Mutagenesis of an Amino Acid Triplet Repeat at $M_1$ and $M_2$ Muscarinic Receptors on Receptor Function)

  • 이석용;이상복
    • 대한약리학회지
    • /
    • 제32권3호
    • /
    • pp.311-321
    • /
    • 1996
  • $M_1$$M_2$ 무스카린성 수용체의 두 번째 transmembrane domain의 C-말단에는 leucine(L), tyrosine(Y), threonine(T)로 구성된 3중체(triplet)가 있다. 이 3중체는 $M_2$ 무스카린성 수용체에서는 두 번째 transmembrane domain과 첫 번째 세포외 고리사이의 연접부위에서 LYT-LYT의 반복구조로 존재하며 $M_1$ 무스카린성 수용체에서는 흥미롭게도 LYT-TYL의 역상구조로 존재한다. 본 연구에서는 site-directed mutagenesis방법을 사용하여 이와 같은 특이한 구조적차이가 두 subtype의 수용체의 기능상 차이와 관련한 역할을 가지고 있는지를 확인하고자 하였다. $M_1$ 수용체에서는 LYTTYL서열을 $M_2$ 수용체의 서열에 해당하는 LYTLYT로 mutation시켰으며 $M_2$ 수용체에서는 LYTLYT8서열을 $M_1$ 수용체의 서열에 해당하는 LYTTYL로 mutation시켰다. 이와같은 mutation은 $M_1$$M_2$ 수용체에서 효능제 carbachol의 수용체 결합친화력에 유의한 변화를 주지 않았다. 또한 $M_1$ 수용체에서의 mutation은 cyclic AMP 증가작용에 대한 coupling은 변화시키지 않고 phosphoinositides (PI) hydrolysis 촉진작용과 세포내 $Ca^{2+}$ 농도 상승을 현저히 증가시켰다. 또한 $M_2$ 수용체에서의 mutation은 adenylate cyclase 억제에 대한 coupling은 변화시키지 않고 PI hydrolysis 촉진을 약간 증가 시켰다. 이상의 결과는 $M_1$$M_2$ 수용체에서 LYTTYL/LYTLYT 아미노산 서열의 차이는 두 수용체의 PI hydrolysis에 대한 coupling을 조절하는 역할을 하지만, 두 수용체 사이에서 ligand 결합과 신호전달계의 차이를 구분하는데 중요한 역할을 하지는 않는다.

  • PDF

노화에 따른 면역지표의 변화에 관한 연구 (Modulation of Immune Parameters by Aging Process)

  • 이지혜;정지혜;김현숙
    • Journal of Nutrition and Health
    • /
    • 제43권2호
    • /
    • pp.152-160
    • /
    • 2010
  • 본 연구에서는 노화에 따른 영양 태와 면역지표의 변화를 알아보기 위해 연령대가 다른 성인 여성 총 54명을 대상으로 실시하였다. 연령 이외의 환경적 유전적 차이를 최소화하기 위하여 대부분이 한 가족 내 3세대, 즉 20대인 딸, 40~50대인 어머니, 60세 이상의 할머니들로 구성시켰다. 대상자들의 신체 계측, 식이 섭취 조사, 생화학적 검사를 통해 영양상태를 판정하였고, 면역지표를 평가하기 위해 총 백혈구 수 및 백혈구 백분율을 측정하였다. 또한 세포매개성 면역능력을 측정하기 위해 T ltmphocyte과 CD4 +, CD8 + 그리고 NK cells의 수와 비율을 측정하였으며 체액성 면역지표를 알아보기 위해 면역 글로불린 G, A, M의 농도를 측정하였다. 신체 계측 결과 연령이 증가됨에 따라 평균 체지방 함량은 증가하였고 체내 총 수분량과 근육의 양은 줄어드는 경향을 나타냈다. 각 연령별 영양 섭취 상태를 조사한 결과 20대 여대생군의 경우 열량과 철분을 제외한 다른 영양소의 영양상태는 비교적 양호하였으나 3대 영양소의 열량 섭취 비율 또한 한국인 영양섭취기준과 거의 일치하는 것으로 나타났다. 40~50대 어머니군에서도 철분의 영양 상태가 권장량에 비해 부족하였고, 할머니군에서는 에너지 섭취량은 권장량에 비해 낮은 반면 단백질과 철분의 섭취량은 양호한 것으로 나타났다. 총 백혈구 수 및 백혈구 백분율은 조사 대상자 대부분이 정상 범위에 속해 연령 증가에 따른 유의성이 없었으며, T lymphocyte 및 CD4 +, CD8 +와 NK cells을 조사한 결과 T lymphocyte과 CD4 + T cells은 연령 증가에 따라 유의적 차를 보이지 않는 반면 CD8 + T cells은 연령이 증가할수록 유의적으로 감소하여 CD4 +:CD8 +의 비율이 노화됨에 따라 증가하는 경향을 나타냈고, 전체 lymphocyte 중에서 NK cells과 B lymphocyte 수는 유의적 차를 보이지 않았으나 면역 글로불린 M은 노화에 따라 그 농도가 감소하는데 비해 면역 글로불린 A는 각 군별 유의성이 없었고, 면역 글로불린 G는 어머니군에서 유의적으로 높았다. 영양 면역학은 비교적 최근의 관심 분야이고 더욱이 국내에서 이 분야의 연구는 매우 미흡한 실정이다. 그러므로 급속히 발달하고 있는 면역학 이론의 올바른 이해와 새로운 연구 방법의 신속한 적용, 정확한 연구 결과의 해석으로 좀더 구체적이고 체계적인 연구를 통해 각 영양소가 인체 면역지표에 미치는 구체적 메커니즘을 밝히고 면역능 증진을 위한 생리적 활성을 줄 수 있는 각 영양소의 권장량에 대한 연구가 앞으로 이루어져야 할 것으로 보인다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF