• Title/Summary/Keyword: Difference matrix

Search Result 970, Processing Time 0.038 seconds

Matched Field Source Localization and Interference Suppression Using Mode Space Estimation (정합장 기반 표적 위치추정 시 모드공간 분석을 통한 간섭 신호 제거 기법)

  • Kim, Kyung-Seop;Seong, Woo-Jae;Pyo, Sang-Woo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.40-46
    • /
    • 2008
  • Weak target detection and localization in the presence of loud surface ship noise is a critical problem for matched field processing (MFP) in shallow water. For stationary sources, each signal component of received signal can be separated and interference can be suppressed using eigen space analysis schemes. However, source motion, in realistic cases, causes spreading of signal energies in their subspace. In this case, eigenvalues of target and interfere signal components are mixed and hard to be separated with usual phone space eigenvector decomposition (EVD) approaches. Our technique is based on mode space and utilizes the difference in their physical characteristics of surface and submerged sources. Performing EVD for modal cross spectral density matrix, interference components in the mode amplitude subspace can be classified and eliminated. This technique is demonstrated with synthetic data, and results are discussed.

Vaccine hesitancy: acceptance of COVID-19 vaccine in Pakistan

  • Sheze Haroon Qazi;Saba Masoud;Miss Ayesha Usmani
    • Clinical and Experimental Vaccine Research
    • /
    • v.12 no.3
    • /
    • pp.209-215
    • /
    • 2023
  • Purpose: The delay in acceptance or refusal to get vaccinated despite the availability of services is called vaccine hesitancy. The Global Polio Eradication Initiative in Pakistan faced consistent barriers preventing the eradication of the disease in the country. Similarly with the advent of the coronavirus disease 2019 (COVID-19) pandemic mass vaccination drives were initiated to a vaccine hesitant population. The aim of this study is to explore the prevalence and reasons for COVID-19 vaccine hesitancy in the Pakistani population. Materials and Methods: Cross-sectional study conducted during July to September 2021 using a snowball sampling technique targeting the adult population of Pakistan. The modified version of the vaccine hesitancy questionnaire related to the Strategic Advisory Group of Experts on Immunization Vaccine Hesitancy matrix was distributed online. Results: Out of 973 participants, 52.4% were immediately willing to take the vaccine and constituted the acceptance group whereas the remaining 47.6% who were still not sure formed the hesitant group. Support from leaders was found to be statistically significant for the difference between the hesitant and acceptance groups (p-value=0.027). Hesitant people were concerned about the effectiveness of the vaccine (60.9%) and potential side effects (57.9%) as it was not sufficiently tested prior to launch (44.7%). Age and education were significant factors affecting the acceptance of vaccination. The most trusted source of information regarding vaccination was health care workers (43.8%). Conclusion: A moderately high prevalence of vaccine hesitancy was reported in Pakistan. To overcome it, policymakers need to address the reasons for it. Leaders, celebrities, and healthcare workers can play an instrumental role in dispelling conspiracy theories regarding vaccines and making the vaccination drive a success.

Fused Filament Fabrication of Poly (Lactic Acid) Reinforced with Silane-Treated Cellulose Fiber for 3D Printing

  • Young-Rok SEO;Birm-June KIM
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.205-220
    • /
    • 2024
  • Various polylactic acid (PLA) blends were reinforced with untreated or silane-treated micro-sized cellulose fiber (MCF), successfully prepared as 3D printing filaments and then printed using a fused filament fabrication (FFF) 3D printer. In this study, we focused on developing 3D-printed MCF/PLA composites through silane treatment of MCF and investigating the effect of silane treatment on the various properties of FFF 3D-printed composites. Fourier transform infrared spectra confirmed the increase in hydrophobic properties of silane-treated MCF by showing the new absorption peaks at 1,100 cm-1, 1,030 cm-1, and 815 cm-1 representing C-NH2, Si-O-Si, and Si-CH2 bonds, respectively. In scanning electron microscope images of silane-treated MCF filled PLA composites, the improved interfacial adhesion between MCF and PLA matrix was observed. The mechanical properties of the 3D-printed MCF/PLA composites with silane-treated MCF were improved compared to those of the 3D-printed MCF/PLA composites with untreated MCF. In particular, the highest tensile and flexural modulus values were observed for S-MCF10 (5,784.77 MPa) and S-MCF5 (2,441.67 MPa), respectively. The thermal stability of silane-treated MCF was enhanced by delaying the initial thermal decomposition temperature compared to untreated MCF. The thermal decomposition temperature difference at T95 was around 26℃. This study suggests that the effect of silane treatment on the 3D-printed MCF/PLA composites is effective and promising.

Comparison of radiomics prediction models for lung metastases according to four semiautomatic segmentation methods in soft-tissue sarcomas of the extremities

  • Heesoon Sheen;Han-Back Shin;Jung Young Kim
    • Journal of the Korean Physical Society
    • /
    • v.80
    • /
    • pp.247-256
    • /
    • 2022
  • Our objective was to investigate radiomics signatures and prediction models defined by four segmentation methods in using 2-[18F]fluoro-2-deoxy-d-glucose positron emission tomography (18F-FDG PET) imaging of lung metastases of soft-tissue sarcomas (STSs). For this purpose, three fixed threshold methods using the standardized uptake value (SUV) and gradient-based edge detection (ED) were used for tumor delineation on the PET images of STSs. The Dice coefficients (DCs) of the segmentation methods were compared. The least absolute shrinkage and selection operator (LASSO) regression and Spearman's rank, and Friedman's ANOVA test were used for selection and validation of radiomics features. The developed radiomics models were assessed using ROC (receiver operating characteristics) curve and confusion matrices. According to the results, the DC values showed the biggest difference between SUV40% and other segmentation methods (DC: 0.55 and 0.59). Grey-level run-length matrix_run-length nonuniformity (GLRLM_RLNU) was a common radiomics signature extracted by all segmentation methods. The multivariable logistic regression of ED showed the highest area under the ROC (receiver operating characteristic) curve (AUC), sensitivity, specificity, and accuracy (AUC: 0.88, sensitivity: 0.85, specificity: 0.74, accuracy: 0.81). In our research, the ED method was able to derive a significant model of radiomics. GLRLM_RLNU which was selected from all segmented methods as a meaningful feature was considered the obvious radiomics feature associated with the heterogeneity and the aggressiveness. Our results have apparently showed that radiomics signatures have the potential to uncover tumor characteristics.

Quantum transport of doped rough-edged graphene nanoribbons FET based on TB-NEGF method

  • K.L. Wong;M.W. Chuan;A. Hamzah;S. Rusli;N.E. Alias;S.M. Sultan;C.S. Lim;M.L.P. Tan
    • Advances in nano research
    • /
    • v.17 no.2
    • /
    • pp.137-147
    • /
    • 2024
  • Graphene nanoribbons (GNRs) are considered a promising alternative to graphene for future nanoelectronic applications. However, GNRs-based device modeling is still at an early stage. This research models the electronic properties of n-doped rough-edged 13-armchair graphene nanoribbons (13-AGNRs) and quantum transport properties of n-doped rough-edged 13-armchair graphene nanoribbon field-effect transistors (13-AGNRFETs) at different doping concentrations. Step-up and edge doping are used to incorporate doping within the nanostructure. The numerical real-space nearest-neighbour tight-binding (NNTB) method constructs the Hamiltonian operator matrix, which computes electronic properties, including the sub-band structure and bandgap. Quantum transport properties are subsequently computed using the self-consistent solution of the two-dimensional Poisson and Schrödinger equations within the non-equilibrium Green's function method. The finite difference method solves the Poisson equation, while the successive over-relaxation method speeds up the convergence process. Performance metrics of the device are then computed. The results show that highly doped, rough-edged 13-AGNRs exhibit a lower bandgap. Moreover, n-doped rough-edged 13-AGNRFETs with a channel of higher doping concentration have better gate control and are less affected by leakage current because they demonstrate a higher current ratio and lower off-current. Furthermore, highly n-doped rough-edged 13-AGNRFETs have better channel control and are less affected by the short channel effect due to the lower value of subthreshold swing and drain-induced barrier lowering. The inclusion of dopants enhances the on-current by introducing more charge carriers in the highly n-doped, rough-edged channel. This research highlights the importance of optimizing doping concentrations for enhancing GNRFET-based device performance, making them viable for applications in nanoelectronics.

Optimization of intelligent prosthetic hands using artificial neural networks and nanoscale technologies for enhanced performance

  • Jialing Li;Gongxing Yan;Zefang Wang;Belgacem Bouallegue;Tamim Alkhalifah
    • Advances in nano research
    • /
    • v.17 no.4
    • /
    • pp.369-383
    • /
    • 2024
  • Annular nano-electromechanical systems (NEMS) in intelligent prosthetic hands enhance precision by serving as highly sensitive sensors for detecting pressure, vibrations, and deformations. This improves feedback and control, enabling users to modulate grip strength and tactile interaction with objects more effectively, enhancing prosthetic functionality. This research focuses on the electro-thermal buckling behavior of multi-directional poroelastic annular NEMS used as temperature sensors in airplanes. In the present study, thermal buckling performance of nano-scale annular functionally graded plate structures integrated with piezoelectric layers under electrical and extreme thermal loadings is investigated. In this regard, piezoelectric layers are placed on a disk made of metal matrix composite with graded properties in three radials, thickness and circumferential directions. The grading properties obey the power-law distribution. The whole structure is embedded in thermal environment. To model the mechanical behavior of the structure, a novel four-variable refined quasi-3D sinusoidal shear deformation theory (RQ-3DSSDT) is engaged in obtaining displacement field in the whole structure. The validity of the results is examined by comparing to a similar problem published in literature. The results of the buckling behavior of the structure in different boundary conditions are presented based on the critical temperature rise and critical external voltage. It is demonstrated that increase in the nonlocal and gradient length scale factor have contradicting effects on the critical temperature rise. On the other hand, increase in the applied external voltage cause increase in the critical temperature. Effects of other parameters like geometrical parameters and grading indices are presented and discussed in details.

Epoxy/BaTiO3 (SrTiO3) composite films and pastes for high dielectric constant and low tolerance embedded capacitors fabrication in organic substrates

  • Paik Kyung-Wook;Hyun Jin-Gul;Lee Sangyong;Jang Kyung-Woon
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2005.09a
    • /
    • pp.201-212
    • /
    • 2005
  • [ $Epoxy/BaTiO_3$ ] composite embedded capacitor films (ECFs) were newly designed fur high dielectric constant and low tolerance (less than ${\pm}15\%$) embedded capacitor fabrication for organic substrates. In terms of material formulation, ECFs are composed of specially formulated epoxy resin and latent curing agent, and in terms of coating process, a comma roll coating method is used for uniform film thickness in large area. Dielectric constant of $BaTiO_3\;&\;SrTiO_3$ composite ECF is measured with MIM capacitor at 100 kHz using LCR meter. Dielectric constant of $BaTiO_3$ ECF is bigger than that of $SrTiO_3$ ECF, and it is due to difference of permittivity of $BaTiO_3\;and\;SrTiO_3$ particles. Dielectric constant of $BaTiO_3\;&\;SrTiO_3$ ECF in high frequency range $(0.5\~10GHz)$ is measured using cavity resonance method. In order to estimate dielectric constant, the reflection coefficient is measured with a network analyzer. Dielectric constant is calculated by observing the frequencies of the resonant cavity modes. About both powders, calculated dielectric constants in this frequency range are about 3/4 of the dielectric constants at 1 MHz. This difference is due to the decrease of the dielectric constant of epoxy matrix. For $BaTiO_3$ ECF, there is the dielectric relaxation at $5\~9GHz$. It is due to changing of polarization mode of $BaTiO_3$ powder. In the case of $SrTiO_3$ ECF, there is no relaxation up to 10GHz. Alternative material for embedded capacitor fabrication is $epoxy/BaTiO_3$ composite embedded capacitor paste (ECP). It uses similar materials formulation like ECF and a screen printing method for film coating. The screen printing method has the advantage of forming capacitor partially in desired part. But the screen printing makes surface irregularity during mask peel-off, Surface flatness is significantly improved by adding some additives and by applying pressure during curing. As a result, dielectric layer with improved thickness uniformity is successfully demonstrated. Using $epoxy/BaTiO_3$ composite ECP, dielectric constant of 63 and specific capacitance of 5.1nF/cm2 were achieved.

  • PDF

Measurement and Algorithm Calculation of Maxillary Positioning Change by Use of an Optoelectronic Tracking System Marker in Orthognathic Surgery (악교정수술에서 광전자 포인트 마커를 이용한 상악골 위치 변화의 계측 및 계산 방법 연구)

  • Park, Jong-Woong;Kim, Soung-Min;Eo, Mi-Young;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.233-240
    • /
    • 2011
  • Purpose: To apply a computer assisted navigation system to orthognathic surgery, a simple and efficient measuring algorithm calculation based on affine transformation was designed. A method of improving accuracy and reducing errors in orthognathic surgery by use of an optical tracking camera was studied. Methods: A total of 5 points on one surgical splint were measured and tracked by the Polaris $Vicra^{(R)}$ (Northern Digital Inc Co., Ontario, Canada) optical tracking system in two cases. The first case was to apply the transformation matrix at pre- and postoperative situations, and the second case was to apply an affine transformation only after the postoperative situation. In each situation, the predictive measuring value was changed to the final measuring value via an affine transformation algorithm and the expected coordinates calculated from the model were compared with those of the patient in the operation room. Results: The mean measuring error was $1.027{\pm}0.587$ using the affine transformation at pre- and postoperative situations and the average value after the postoperative situation was $0.928{\pm}0.549$. The farther a coordinate region was from the reference coordinates which constitutes the transform matrixes, the bigger the measuring error was found which was calculated from an affine transformation algorithm. Conclusion: Most difference errors were brought from mainly measuring process and lack of reproducibility, the affine transformation algorithm formula from postoperative measuring values by using of optic tracking system between those of model surgery and those of patient surgery can be selected as minimizing the difference error. To reduce coordinate calculation errors, minimum transformation matrices must be used and reference points which determine an affine transformation must be close to the area where coordinates are measured and calculated, as well as the reference points need to be scattered.

An analysis of Factorial structure of Kinematic variables in Bowling (볼링의 운동학적 분석과 주요인 구조분석)

  • Lee, Kyung-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.381-392
    • /
    • 2002
  • This study attempted to indentify changeability of the factorial structure of kinematic analysis in bowling. Subjects of group composed of three groups : Higher bowers who are national representative bowers with 200 average point and one pro-bowler. Middle bowlers who are three common persons with 170 average points. Lower bowler who are three common persons with 150 average points. Motion analysis on throw motion in three groups respectively has been made through three-dimension cinematography using DLT method. Two high-speed video camera at operating 180 and 60 frame per secondary. T-test factorial structure analysis has been used to define variable relations. It was concluded that : 1. The difference of x1, x2, x4, x8, x9, x11, x12, x13 where significant between two group. 2. The difference of number of spin and angle of the back-hand where statistically significant between two group(p<.001, p<.05) 3. The correlation over r=.5 between the kinematic data x1, x2, x3, x9, x10, x11. In the rotation loading matrix Factor 1 was x1, x2, x9, x10 and Factor 2 relates to x3, x11. 4. In order to obtain the factor score as follow as ; Factor 1 = (0.248)X1 + (0.265)X2 + (-0.074)X3 + (0.259)X9 + (0.259)X10 + (-0.025)X11 Factor 2=(-0.016)X1 + (-0.055)X2 + (0.84)X3 + (-0.013)X9 + (-0.007)X10 + (0.553)X11.

Impact of Emission Inventory Choices on PM10 Forecast Accuracy and Contributions in the Seoul Metropolitan Area (배출량 목록에 따른 수도권 PM10 예보 정합도 및 국내외 기여도 분석)

  • Bae, Changhan;Kim, Eunhye;Kim, Byeong-Uk;Kim, Hyun Cheol;Woo, Jung-Hun;Moon, Kwang-Joo;Shin, Hye-Jung;Song, In Ho;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.497-514
    • /
    • 2017
  • This study quantitatively analyzes the effects of emission inventory choices on the simulated particulate matter (PM) concentrations and the domestic/foreign contributions in the Seoul Metropolitan Area (SMA) with an air quality forecasting system. The forecasting system is composed of Weather Research and Forecasting (WRF)-Sparse Matrix Operator Kernel Emissions (SMOKE)-Community Multi-Scale Air Quality (CMAQ). Different domestic and foreign emission inventories were selectively adopted to set up four sets of emissions inputs for air quality simulations in this study. All modeling cases showed that model performance statistics satisfied the criteria levels (correlation coefficient >0.7, fractional error <50%) suggested by previous studies. Notwithstanding the apparently good model performance of total PM concentrations by all emission cases, annual average concentrations of simulated total PM concentrations varied up to $20{\mu}g/m^3$ (160%) depending on the combination of emission inventories. In detail, the difference in simulated annual average concentrations of the primary PM coarse (PMC) was up to $25.2{\mu}g/m^3$ (6.5 times) compared with other cases. Furthermore, model performance analyses on PM species showed that the difference in the simulated primary PMC led to gross model overestimation in general, which indicates that the primary PMC emissions need to be improved. The contribution analysis using model direct outputs indicated that the domestic contributions to the annual average PM concentrations in the SMA vary from 44% to 67%. To account for the uncertainty of the simulated concentration, the contribution correction factor method proposed by Bae et al. (2017) was applied, which resulted in converged contributions(from 48% to 57%). We believe this study shows that it is necessary to improve the simulated concentrations of PM components in order to enhance the accuracy of the forecasting model. It is deemed that these improvements will provide more accurate contribution results.