• 제목/요약/키워드: Difference coefficient (D)

검색결과 327건 처리시간 0.031초

Experimental Investigation of R-22 Condensation in Tubes with Small Inner Diameter

  • Kim, Nae-Hyun;Cho, Jin-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.45-54
    • /
    • 1999
  • In this study, condensation heat transfer experiments were conducted in two small diameter (ø17.5, ø4.0) tubes. Comparison with the existing in-tube condensation heat transfer correlations indicated that these correlations over predict the present data. For example, Akers correlation over predicted the data up to 104 %. The condensation heat transfer coefficient of the ø4.0 I.D. tube was smaller than that of the ø7.5 I.D tube; at the mass velocity of 300 kg/$m^2$s, the difference was 12 %. The pressure drop data of the small diameter tubes were highly (two to six times) over predicted by the Lockhart-Martinelli correlation. Sub-cooled forced convection heat transfer test confirmed that Gnielinski's single phase heat transfer correlation predicted the data reasonably well.

  • PDF

소구경 원관내의 R-22 응축열전달에 대한 실험 (Experiments on R-22 condensation heat transfer in small diameter tubes)

  • 김내현;조진표;김정오;김만회;윤재호
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.271-281
    • /
    • 1998
  • In this study, condensation heat transfer experiments were conducted with two small diameter(ø7.5, ø4.0) tubes. Comparison with existing in-tube condensation heat transfer correlations indicated that the correlations overpredict the present data. For example, Akers correlation overpredicts the data upto 104%. The condensation heat transfer coefficient of the ø4.0 I.D. tube was smaller than that of the ø7.5 I.D tube; at the mass velocity of 300kg/$m^2$s, the difference was 12%. The pressure drop data of the small diameter tubes ware highly(two to six times) overpredicted by the Lockhart-Martinelli correlation. Subcooled forced convection heat transfer test confirmed that Gnielinski's single phase heat transfer correlation predicted the data reasonably well.

  • PDF

비중 차이에 따른 테트라포드 안정계수 변화에 관한 실험적 연구 (Experimental Investigation on the Change of Stability Coefficient of Tetrapod According to Difference in Density)

  • 이달수;오상호;조봉석
    • 한국해안·해양공학회논문집
    • /
    • 제28권3호
    • /
    • pp.124-131
    • /
    • 2016
  • 이 연구에서는 수리실험을 통해 비중이 서로 다른 테트라포드의 Hudson식에 의한 안정계수($K_D$) 변화 특성을 고찰하였다. 수리실험은 사면 경사 1:1.5인 경사식 방파제에 대하여 반복실험 없이 1회 수행되었으며, 본 실험 조건에서는 고비중 테트라포드의 안정계수가 더 크게 나타났다. 이는 테트라포드 안정계수가 비중에 따라서 달라지게 됨을 보여주는 결과이다. 향후 보다 많은 실험을 통해서 테트라포드의 비중이 안정계수에 미치는 영향을 자세히 고찰할 필요가 있다.

Correlation study of in vitro and in vivo test for SPF (Sun Protection Factor)

  • Jihyun, Jihyun-Bae;Sungyeon Ahn;Lee, Haekwang;Seongjoon Moon;Ihseop Chang
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.407-416
    • /
    • 2003
  • In this study, we evaluate the correlation between in vitro and in vivo determination of SPF of sunscreen products containing various ingredients depending on emulsification system. For in vitro approach, we determined SPF by the method of Diffey and Robson using an TransporeTM tape(3M Health care, USA) and SPF 290-analyzer(Optometrics Co. USA). SPF values and standard deviations are calculated and displayed after completion of the run. In vivo SPF values are determined according to KFDA (the Korea Food and Drug Administration) method in panels of Fitzpatrick's skin type II or III. We investigated the difference in SPF data of sunscreen ingredient according to emulsification system. The in vivo SPF data is high in water-in oil(W/O) emulsion than in oil-in water(O/W) emulsion samples. The difference may be due to the particular behavior in each vehicles and its presence on skin surface may produce a different sunscreen film. We obtained the corrlation coefficient between in vitro and in vivo SPF data for O/W (R-squre=0.72 )and W/O emulsion(R-squre=0.77). From these results, we suggest the improvement of methodology using Transpore$^{TM}$ tape as substrate to increase the predictability of in vitro method.d.

  • PDF

물성치 적용 기법에 따른 하이브리드 풍력 블레이드 동적특성 해석에 관한 연구 (A Study on Dynamic Characteristics Analysis of Hybrid Wind Power Blades according to Material Properties Method)

  • 강병윤;한정영;홍철현;문병영
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.5-11
    • /
    • 2012
  • In this paper, the heat transfer coefficient measurement techniques using TSP(temperature sensitive paint) were introduced and the results of a comparative study on the heat transfer coefficient measurement by steady state and transient TSP techniques were discussed. The distributions of heat transfer coefficient by a single $60^{\circ}$ inclined impingement jet on a flat surface were measured by both techniques. Tested Reynolds number based on the jet diameter (d) was 30,000 and the distance between jet exit and target plate (L) was fixed at 10d. Results showed that the measured Nusselt number by both techniques indicated significant difference except near the center of impingement jet. Also, the heat transfer coefficients measured by the transient TSP technique were affected by the reference temperature of the jet. Based on the measured data, characteristics of both TSP techniques were analyzed and suggestions for applying them were also given.

Intravoxel Incoherent Motion Magnetic Resonance Imaging for Assessing Parotid Gland Tumors: Correlation and Comparison with Arterial Spin Labeling Imaging

  • Gao Ma;Xiao-Quan Xu;Liu-Ning Zhu;Jia-Suo Jiang;Guo-Yi Su;Hao Hu;Shou-Shan Bu;Fei-Yun Wu
    • Korean Journal of Radiology
    • /
    • 제22권2호
    • /
    • pp.243-252
    • /
    • 2021
  • Objective: To compare and correlate the findings of intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging and arterial spin labeling (ASL) imaging in characterizing parotid gland tumors. Materials and Methods: We retrospectively reviewed 56 patients with parotid gland tumors evaluated by MR imaging. The true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and fraction of perfusion (f) values of IVIM imaging and tumor-to-parotid gland signal intensity ratio (SIR) on ASL imaging were calculated. Spearman rank correlation coefficient, chi-squared, Mann-Whitney U, and Kruskal-Wallis tests with the post-hoc Dunn-Bonferroni method and receiver operating characteristic curve assessments were used for statistical analysis. Results: Malignant parotid gland tumors showed significantly lower D than benign tumors (p = 0.019). Within subgroup analyses, pleomorphic adenomas (PAs) showed significantly higher D than malignant tumors (MTs) and Warthin's tumors (WTs) (p < 0.001). The D* of WTs was significantly higher than that of PAs (p = 0.031). The f and SIR on ASL imaging of WTs were significantly higher than those of MTs and PAs (p < 0.05). Significantly positive correlation was found between SIR on ASL imaging and f (r = 0.446, p = 0.001). In comparison with f, SIR on ASL imaging showed a higher area under curve (0.853 vs. 0.891) in discriminating MTs from WTs, although the difference was not significant (p = 0.720). Conclusion: IVIM and ASL imaging could help differentiate parotid gland tumors. SIR on ASL imaging showed a significantly positive correlation with f. ASL imaging might hold potential to improve the ability to discriminate MTs from WTs.

Cyclic Difference Set을 이용한 Interleaved Thinned 평면 배열 설계 (Design of Interleaved Thinned Planar Arrays Using Cyclic Difference Set)

  • 권지나;황금철;박준영;김선주;김동환
    • 한국전자파학회논문지
    • /
    • 제23권12호
    • /
    • pp.1351-1358
    • /
    • 2012
  • 본 논문에서는 다기능 레이더에 적용 가능한 interleaved thinned 평면 배열 설계 기법을 제안하였다. 제안된 interleaved 평면 배열은 낮은 부엽 준위를 도출하기 위해 cyclic difference set(DS)이 적용된 비주기 부배열로 구성되었다. DS를 이용한 thinned 평면 부배열의 부엽 준위는 DS 파라미터에 의해 예측 가능하므로 부배열 설계에 자기상관 계수(autocorrelation coefficient)가 비슷한 DS와 complementary DS를 적용함으로써 서로 유사한 부엽 준위 특성을 구현하였다. 또한, 두 부배열의 최적 PSL(Peak Sidelobe Level)을 도출하기 위해서 interleaved 평면 배열 설계에 DS의 특성인 cyclic shift를 적용하였다. 최적화된 배열 안테나의 두 부배열은 각각 -12.47 dB와 -10.34 dB로 낮은 PSL 특성을 나타내었다.

지하철 승강장의 음원-수음점 거리에 따른 실내음향 평가지수 특성 (Characteristic of room acoustical parameters with source-receiver distance on platform in subway stations)

  • 김수홍;송은성;김정훈;이송미;류종관
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.615-625
    • /
    • 2021
  • 본 연구에서는 지하철 승강장에 적합한 실내음향 설계기준 제시에 앞서, 현재의 지하철 승강장의 위치별 실내음향 특성을 파악하기 위해 2개의 지하철 역사 승강장에서 현장 측정을 실시하였다. 승강장의 길이방향에 따른 분석 결과, 음원에서 수음점이 멀어질수록 음압레벨은 감소(최대 차이: 약 14 dB), 잔향시간은 증가하는 경향(최대차이: 0.8 s ~ 1.5 s)이었고, C50과 D50은 감소하는 경향(최대 차이: 5.9 dB ~ 9.1 dB와 31.8 % ~ 37.6 %)인 것으로 나타났다. 공간감의 지표인 Interaural Cross-correlation Coefficient(IACC)는 음원과의 거리에 따른 명확한 경향성은 보이지 않았지만, 전체적으로 0.3이하의 낮은 값을 보였다. 이러한 결과를 살펴보았을 때 지하철 승강장은 일반적으로 강한 반사재로 마감 되었음에도 수음위치에 따라 직접음과 반사음의 다양한 조합이 형성되어 비균일한 음장특성을 갖는 것으로 판단된다. 이는 길이 대비 높이가 낮고 긴 평면형태를 갖는 지하철 승강장에서는 음원과 수음점의 거리에 따라 근접음장과 원음장의 실내음향특성이 뚜렷이 발현되고 있음을 나타난다. 따라서, 승강장의 모든 위치에서 명료한 음정보를 갖춘 실내음향설계를 위해서 승강장에서의 스피커와 수음점 위치별 특성에 기인한 세부 건축 및 전기음향설계가 필요하다.

재생 과정이 니켈-티타늄 호선의 물리적 성질과 표면 거칠기에 미치는 영향 (Effects of recycling on the mechanical properties and the surface topography of Nickel-Titanium alloy wires)

  • 이성호;장영일
    • 대한치과교정학회지
    • /
    • 제30권4호
    • /
    • pp.453-465
    • /
    • 2000
  • 본 연구의 목적은 재생된 니켈-티타늄 호전의 인장물성, 표면거칠기와 마찰력의 변화를 조사하여, 임상적으로 니켈티타늄 호선을 재생하여 사용하는 것이 타당한지를 알아보는 것이다. 수종의 니켈-티타늄 호선과 스테인레스 스틸호선을 처리전(T0: 대조군)과 인공타액에 4주간 처리한 군(T1), 그리고 인공타액 처리후 가압증기 멸균소독한 군(T2)으로 구분하여 인장실험과 주사전자현미경, 3D profilogram을 통한 표면거칠기의 변화와 마찰계수의 변화를 관찰하여 다음과 같은 결과를 얻었다. 1. 인장실험을 하여 최대인장강도, 연신율, 탄성계수를 관찰한 결과 모든 니켈-티타늄 호선에서 재생과정 후에 대조군과 유의한 차이를 보이지 않았다(p<0.05). 단 스테인레스 스틸 호선은 재생과정 후에 최대인장강도, 연신율, 탄성계수에서 통계적으로 유의한 변화를 보였다(p<0.05). 2. 주사전자현미경을 통한 관찰에서 재생후에 Sentalloy를 제외한 호선에서 표면의 점부식(pitting)과 압흔(indentation)이 증가하였다. 3. 3D profilogram을 사용하여 관찰한 표면거칠기(Ra와 Rq)의 변화를 살펴보면, 재생과정 후에 Sentalloy를 제외한 NiTi, Optimalloy, 스테인레스 스틸 호선에서 통계적으로 유의하게 표면거칠기가 증가하였다(p<0.05). 4. 재생과정 후에 시행한 마찰력 실험에서는 최대운동마찰계수가 Sentalloy를 제외한 NiTi, Optimalloy, 스테인레스 스틸호선에서 통계적으로 유의하게 증가하였다(p<0.05). NiTi, Optimalloy의 표면거칠기와 마찰계수의 변화는 임상적으로 영향을 미칠 정도는 아니며, 결과적으로 니켈-티타늄 호선을 재생하면, 인장실험시의 물성과 표면거칠기, 마찰계수의 변화가 임상적으로 문제가 없을 것으로 생각된다.

  • PDF

Al6061 열간단조시 계면열전달계수에 관한 연구 (A study on interface heat transfer coefficient in hot forging of Al6061 by experiments and FE analysis)

  • 권진욱;이영선;권용남;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.219-222
    • /
    • 2005
  • The temperature difference between die and workpiece has frequently caused various surface defects. The non-homogeneous temperature distribution of forged part should be analyzed to prevent the generation of various defects related with the temperature. The surface temperatures were mainly affected by the coefficient of thermal contact conductance. The precise coefficient is necessary to predict accurately the temperature changes of die and workpiece. The experiment is preformed to measure the temperature distribution of die and workpiece in closed die upsetting. And then, the coefficient is classified into function of pressure and confirmed by the comparison between experiments and FE analyses using the other model. The FE analysis to predict the temperature distribution is performed by commercial software $DEFORM-3D^{TM}$. However, it might be impossible to measure directly the temperature distribution of forged part. Therefore, the comparisons between measured temperature and predicted values are performed with the hardness of Al6061-forged part.

  • PDF