• 제목/요약/키워드: Difference coefficient (D)

검색결과 327건 처리시간 0.029초

의료용 폴리머 소재를 활용한 3D 프린팅 인공치아용 사면체 비정질 카본 코팅 기술 연구 (A Study on the Tetrahedral Amorphous Carbon (ta-C) Coating on Medical Polymer Materials for 3D Printing Artificial Teeth)

  • 장영준;김종국;신창희;유성미
    • Tribology and Lubricants
    • /
    • 제38권6호
    • /
    • pp.255-260
    • /
    • 2022
  • This research presents tetrahedral amorphous (ta-C) coating on the artificial tooth for improving the durability and functionality (esthtics, foreign body of tooth) by filtered cathodic vacuum arc (FCVA). A differentiated coating method is required for a ta-C coating on polymer owing to the low melting point of the polymer, inter-facial adhesion, low friction, and non-conductivity. Herein, ta-C coating is applied below 50℃, and the potential difference of the carbon plasma drawn to the substrate was controlled by applying a positive duct bias voltage without using a substrate bias voltage. Consequently, the ta-C coating with a thickness of 70nm using the duct bias condition of 20V with the highest plasma intensity satisfies the esthetics of the artificial tooth and had a 5B level of inter-facial adhesion. In addition, the composite hardness of ta-C/polymer is 380 MPa, and correlations with esthetics, sp3 bonding, and mechanical properties. The friction coefficient (CoF) of the ta-C coating in a water-lubricated environment is 0.07, showing a six-fold reduction in CoF compared with that of a polymer.

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

공간적·시간적 긴밀도를 고려한 개선된 D-InSAR 기법에 관한 연구 (A study on enhanced D-InSAR technique Considering Spatial and Temporal Coherence)

  • 이원응;윤홍식;염민교;김한별
    • 대한공간정보학회지
    • /
    • 제25권2호
    • /
    • pp.67-74
    • /
    • 2017
  • D-InSAR 기법이란 두 장의 SAR 영상의 위상 차이를 이용하여 지표면의 변위를 정밀하게 측정하는 기법이다. D-InSAR를 이용한 정밀한 지표변위량 산출을 위해서는 주영상과 부영상간의 높은 긴밀도가 필수적이다. 기존의 D-InSAR 방식은 주영상과 부영상의 전체 긴밀도를 토대로 지표변위량을 산출하기 때문에, 영상에 긴밀도가 낮은 산지나 나지 등이 포함될 경우 전체적인 지표변위량의 정확도가 낮아지는 문제가 발생한다. 이러한 문제점을 해결하기 위해 본 연구에서는 0.7 이상의 시간적 긴밀도와 공간적 긴밀도를 갖는 지점을 추출하여 불규칙삼각망을 형성, 이를 토대로 지표변위량을 산출하였다. 또한 기존 D-InSAR 방식과 공간적 시간적 긴밀도를 고려한 D-InSAR 방식의 비교분석을 실시하였다. 그 결과 공간적 시간적 긴밀도를 고려한 D-InSAR 기법이 기존의 D-InSAR 기법보다 표준편차, 상대분산, 변동계수, 사분편차가 작게 나타났으며, 지표변위량의 일정한 추세를 파악하는데 용이함을 알 수 있었다.

학생들의 과학교과 불안도와 학습성취도와의 관계 (The Relationship between Students' Science Anxiety and Achivement)

  • 김범기
    • 한국과학교육학회지
    • /
    • 제13권3호
    • /
    • pp.341-358
    • /
    • 1993
  • In this study, the researcher analyzed relationship between stuents' science anxiety and achivement, and investigated the tendency of the science anxiety by students' variables. For the survey of this study. 5,304 stuents were sampled from the population of Korean secondary school. The researcher adopted R&D procedure for the development of SAMS(science anxiety measurement scale) and the SAT(science achivement test). The instrument SAMS consisted of 38-item scale. Cronbach a for SAMS was 0.92, concurrent validity was 0.66. SAT consist of 2O-item, the reliable coefficent of KR-20 was 0.70. The data were analyzed by using Pearson-Product coefficient and Regression analysis for the correlation between dependent and independent variable. The tendency of science anxiety were analyzed Multi-way analysis of variance, and all hypotheses were evaluated as the significant level of 0.001. Results of this study were summarized as follows : 1) The relationship between the science anxiety and the achivement showed negative correlation(r=-O.24) in all grades. 2) The relationship between the male and the female showed negative correlation (male;r=-Q.23. female=-O.22), but 11ths' humanities course and female of the science course didn't showed correlation. 3) The size of city where the school located showed negative correlation to the students anxiety(big city;-O27. medium;-O.24, small city;-O.22). 4) Tendency of students' science anxiety according to the variable of grades and sex variables was found to significant difference. The effects of interaction were found to significant difference between two variables of grade and sex. sex and local, local and grade. The effects among three variables were formed to significant difference grade, sex and local.

  • PDF

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

측정부위별 신생아의 체온 비교 : 고막기준 직장체온, 직장체온, 액와체온, 복부체온 (Comparison by Measurement Sites in Temperature of Neonates : Ear-based rectal, Rectal, Axilla, Abdominal Temperature)

  • 김화순;안영미
    • 대한간호학회지
    • /
    • 제29권4호
    • /
    • pp.903-916
    • /
    • 1999
  • The purpose of this study was to compare the ear-based rectal temperature measured with a tympanic thermometer with the rectal temperature measured with a glass mercury thermometer in order to test the accuracy of tympanic thermometer and to determine relationship among rectal, axilla, and abdominal temperature in neonates. The samples consisted of thirty four neonates admitted to the neonatal intensive care unit and nursery at an university affiliated hospital. The mean age of the subjects was 4.9 days. The ear-based rectal temperatures were taken with a tympanic thermometer in rectal mode (First Temp Genius 3000). Rectal and axilla temperatures were taken with a glass mercury thermometer, Abdominal temperature was continuously monitored with the probe connected to the servo controller of incubator. The results of the study can be summarized as follows : 1. Intrarater comparison : Agreement between the first and the second ear-based rectal temperature was 97% within 0.1$^{\circ}C$. 2. Comparison of ear-based rectal temperature and the rectal temperature from a glass mercury thermometer : ear-based rectal temperature ranged from 36.95$^{\circ}C$d to 37.95$^{\circ}C$, with a mean of 37.58$^{\circ}C$(SD=0.22$^{\circ}C$). Rectal temperature from a glass mercury thermometer ranged from 36.2$0^{\circ}C$ to 37.2$0^{\circ}C$, with a mean 36.75$^{\circ}C$(SD=0.29). The mean difference between both temperatures was 0.84$^{\circ}C$. The correlation coefficient between both temperatures was r=0.77(p=0.00). 3. Comparison of rectal and axilla temperature : Axilla temperature ranged from 35.8$0^{\circ}C$ to 37.1$0^{\circ}C$, with a mean of 36.55$^{\circ}C$. The mean absolute difference between the rectal and axilla temperature was 0.23$^{\circ}C$. The correlation coefficient between rectal and axilla was r=0.67. 4. Comparison of axilla and abdominal temperature : Abdominal temperature ranged from 36.2$0^{\circ}C$ to 37.0$0^{\circ}C$, with a mean of 36.58$^{\circ}C$. The mean absolute difference between axilla and abdominal temperature was only -0.03$^{\circ}C$. Findings of this study suggest that ear-based rectal temperature overestimates the actual rectal temperatures in neonates. Therefore, the interchangeble use of both temperatures in clinics seems problematic. The site offset(adjustment value) programmed in rectal mode of the tympanic thermometer needs to be readjusted. Choosing one optimal site for temperature measurement for each patient, and using the specific site consistently would result in more consistent measurements of changes in body temperature, and thus can be more effective in diagnosing fever or hypothermia.

  • PDF

심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교 (The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT)

  • 송재혁;김경식;이동훈;김성환;박장원
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.87-92
    • /
    • 2015
  • SPECT에서 Uniformity는 균일한 방사능을 갖는 선원에 대하여 균일한 영상을 제공하는 능력이다. 영상에서 다양한 이유로 불균일이 발생하게 되고, 불균일은 artifacts를 발생시켜 임상적으로 진단하는데 영향을 줄 수 있다. Uniformity correction map은 검사에 사용되는 방사성 동위원소를 이용하여 영상에서 Uniformity의 변동폭을 최소화 시켜주는 역할을 한다. 본원에서 시행되고 있는 $^{201}Tl$을 이용한 심근 SPECT에서는 $^{99m}Tc$으로 기본 설정되어 있는 Uniformity correction map을 사용하고 있으며, 이에 따라 본 연구에서는 $^{201}Tl$$^{99m}Tc$ 두 가지 핵종으로 Uniformity correction map을 각각 설정하였을 때 영상의 질에 차이가 있는지 비교 분석하고, 영상의 질을 최적화 할 수 있는 방법에 대하여 모색해 보고자 한다. 장비는 GE Ventri Gamma camera, Flood phantom, Jaszczak ECT phantom을 이용하였다. 실험에 앞서 Collimator를 제거한 상태에서 Detector 표면 중심으로부터 2.5 m 떨어진 지점에 1 cc 주사기에 $^{99m}Tc$ 25.9 Mbq, $^{201}Tl$ 14.8 Mbq의 방사성 동위원소를 주입한 point source를 이용하여 장비사에서 권고하는 $6{\times}10^7count$$^{99m}Tc$$^{201}Tl$ 각각의 방사성 동위원소로 Uniformity Mapping을 실시하였다. Flood phantom에는 $^{201}Tl$ 21.3 kBq/mL, Jaszczak ECT phantom에는 $^{201}Tl$ 33.4 kBq/mL를 주입하여 phantom을 제작하였다. Flood Phantom으로 획득된 데이터는 Xeleris ver 2.05 프로그램을 이용하여 Integral uniformity, Differential uniformity을 두 가지 항목에 대하여 분석하였다. Jaszczak ECT Phantom으로 획득된 데이터를 본원에서 자체 개발한 Interactive Data Language 프로그램에 입력하여 Integral uniformity, Contrast, Coefficient of variation, Spatial Resolution을 4가지 항목에 대하여 분석하였다. Flood phantom test 에서는 $^{99m}Tc$에서의 Flood I.U값은 3.6%, Flood D.U값은 3.0%으로 나타났고, $^{201}Tl$ Flood I.U값은 3.8%, Flood D.U값은 2.1%으로 나타났다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Flood I.U값은 감소하였으나 Flood D.U은 향상되어 Flood 영상에서는 크게 영상의 질이 개선되었는지는 알 수 없었다. 반면 Jaszczak ECT Phantom test에서는 $^{99m}Tc$에서의 SPECT I.U값은 13.99%, Coefficient of variation값은 4.89%, contrast값은 0.69, $^{201}Tl$에서의 SPECT I.U값은 11.37%, Coefficient of variation값은 4.79%, contrast값은 0.78로 나타났으며, 육안 분석을 실시한 Spatial Resolution 항목에서는 육안으로 큰 차이를 보이지 않았다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Spatial Resolution 을 제외한 SPECT I.U, Coefficient of variation, Contrast 세 항목에서 각각 18%, 2%, 13%의 향상된 수치를 보였다는 점에서 영상의 질이 개선되었음을 알 수 있었다. Uniformity correction map이 영상의 질을 크게 좌우할 수 없으나, 개선의 효과를 가져다 준다는 점에서 임상적으로 진단에 영향을 주는지 또한 다른 검사에서 또 다른 방사성 동위원소로 Uniformity correction map을 설정했을 경우 영상의 질을 개선시킬 수 있는지에 관하여 추가적인 연구가 필요할 것으로 사료된다.

  • PDF

자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가 (An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory)

  • 정지연;박승현;이광용;이나루;유기호;박정선;정호근
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF

크리프 예측 영향요인 검토 및 국내 건설현장 콘크리트 배합을 고려한 크리프 예측 모델식 제안 (Investigation on Factors Influencing Creep Prediction and Proposal of Creep Prediction Model Considering Concrete Mixture in the Domestic Construction Field)

  • 문형재;석원균;구경모;이상규;황의철;김규용
    • 한국건축시공학회지
    • /
    • 제19권6호
    • /
    • pp.503-510
    • /
    • 2019
  • 최근 RC 구조물의 건설기술에서는 콘크리트의 크리프에 대한 검토가 이루어져야 한다. 본 연구에서는 콘크리트의 크리프 예측 및 국내 건설현장의 크리프 결과에 영향을 미치는 요인을 검토했다. 크리프 테스트 기간이 길고 압축 강도가 높을수록 크리프 예측 정확도가 높아졌다. 경화 온도가 높을수록 콘크리트의 초기 강도가 높아지지만 크리프 계수의 차이는 시간이 지남에 따라 증가했다. 국내 건설현장 및 실험실에서의 크리프 평가 결과를 기반으로 ACI-209모델을 보완하는 수정 된 예측 모델을 제안했다. 일반~고강도 콘크리트를 사용한 실제 부재의 크리프 예측에서는 테스트 기간과 온도를 정확하게 고려해야한다.