• 제목/요약/키워드: Difference Temperature

검색결과 7,059건 처리시간 0.037초

열전소자의 열적조건 변화에 따른 발전 특성 (Performance of Thermoelectric Power Generator with Various Thermal Conditions)

  • 한훈식;김명기;엄석기;김서영
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.165-170
    • /
    • 2010
  • Experiments have been performed to investigate the key parameters determining the performance of thermoelectric power generation. The experimental results obtained show that the power output significantly increases with the temperature difference between cold and hot sides of thermoelectric generator. However, the effect of the hot side temperature under the identical temperature difference on the overall performance of a thermoelectric generator is meager. The conversion efficiency defined as the ratio of the power generated to the heat absorbed at the hot side increases with the temperature difference. The behavior of the thermoelectric generator is shown to be consistent with the theoretical analysis. The optimum current giving the maximum conversion efficiency and the maximum conversion efficiency are linearly increased with the temperature difference.

MF증발기 기초 형상 설계에 관한 연구 (A Study on the Basic Shape of an MF Evaporator)

  • 박용석;성홍석;서정세
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.39-44
    • /
    • 2019
  • The evaporator is a key driver of an air conditioning system's efficiency. In this study, we study methods of maximizing the efficiency of a Massey Ferguson (MF) evaporator by measuring how the cooling performance of different shapes vary with temperature. We varied the tube insertion depth as well as the shape of the evaporator's header and tube. When we compare header shapes of "D", "Ellipse", and "Quadrangle" types, we find that the elliptical header creates the smallest pressure loss and the highest temperature difference. Between tube shapes of "Rectangular", "Projection", and "Circular" types, the "Projection" type tube creates the most temperature difference. We also investigated the depth of tube insertion in the header and find that tube insertion of 5 - 10 mm is feasible; we selected the depths of 5, 7, and 10 mm since they corresponded to approximately 30%, 50%, and 70% of the total width of the header. The tube insertion test demonstrated that a tube insertion depth of 7 mm creates the least pressure loss and the highest temperature difference. In conclusion, the optimal evaporator design uses an "Ellipse" type header, "Projection" type tube, and a tube insertion depth between 30 and 50% of the header width.

온난 및 한랭시즌의 우리나라 지상기온 평가 알고리즘 개발 (Development of Estimation Algorithm of Near-Surface Air Temperature for Warm and Cold Seasons in Korea)

  • 김도용
    • 대한공간정보학회지
    • /
    • 제23권4호
    • /
    • pp.11-16
    • /
    • 2015
  • 시공간적 기온정보는 지구온난화와 기후변화의 이해에 있어서 중요한 기상요소이다. 본 연구에서는 인공위성 원격탐사로부터 획득된 공간적으로 균질한 지표면 정보를 이용하여 우리나라 지상기온 평가 알고리즘을 개발하였다. LST(Land Surface Temperature), NDWI(Normalized Difference Water Index), NDVI(Normalized Difference Vegetation Index)를 독립변수로 하는 지상기온 추정을 위한 다중회귀모형을 제안하고, 우리나라의 지역기후변화를 고려하기 위하여 온난시즌과 한랭시즌에 대한 모형의 회귀상수 및 회귀계수를 도출하였다. 개발된 기온 추정 알고리즘에 의해 산출된 온난 및 한랭시즌의 기온정보는 지상관측기온과 비교하여 우수한 상관관계를 보였고, $3^{\circ}C$ 미만의 RMSE와 거의 0에 가까운 BIAS로 매우 높은 일치성을 보였다. 따라서 인공위성 지표면 원격탐사자료를 활용하고 온난 및 한랭시즌의 구분을 적용한 기온 평가 알고리즘은 우리나라의 지역기후를 평가하는데 있어서 간략하고 유용한 수단이 될 수 있으리라 기대된다.

지중가온이 온실의 난방부하에 미치는 영향 (The Effect of Soil Warming on the Greenhouse Heating Load)

  • 남상운
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

재료(材料)에 따른 뜸의 연소(燃燒) 특성(特性)에 대한 연구(硏究) (An Experimental Study on the Characteristics of Moxa Combustion in the Moxa Materials)

  • 박영배;강성길;김창환;고형균;오환섭;허웅
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.222-233
    • /
    • 1996
  • In order to understand the stimulation quality of Artemisine Vulgaris Folium(Bong), Mori Ramulus(Sangi) and Persicae Ramulus(Dogi) combustion, and get the basic data for the development of electric moxibustion apparatus, the average temperature, peak temperature, average gradient temperature, maximum gradient temperature and combustion time of heating period on the three moxa materials were measured. 1. The average combustion temperature was high in order of Dogi, Sangi and Bong, and these were acknowledged to have a significant difference each other in the average temperature. 2. The peak combustion temperature among those was high in order of Dogi, Sangi and Bong, and Bong was acknowledged to have significant differences with Dogi and Sangi. Sangi and Dogi however were not acknowledged to have difference each other. 3. The average gradient temperature among those was high in order of Dogi, Sangi and Bong, and Bong was proved to have significant differences with Dogi and Sangi. Sangi and Dogi however were not proved to have difference each other. 4. The maximum temperature among those was high in order of Dogi, Sangi and Bong, bong was acknowledged to have signigicant differences with Dogi and Sangi, but Sangi and Dogi were not proved to have difference each other. 5. The combustion time was short in order of Dogi, Sangi and Bong. Bong was acknowledged to have significant differences with Dogi and Sangi, but Sangi and Dogi were not. In order to understand well the characteristics of combustion, it is required to have a quantitative interpretation of combustion calory, and, in the future, we expect it is required to have a consistent study for the clinical effectiveness and the mutual relationship according to the combustion characteristics.

  • PDF

The effects of LED light quality on ecophysiological and growth responses of Epilobium hirsutum L., a Korean endangered plant, in a smart farm facility

  • Park, Jae-Hoon;Lee, Jung-Min;Kim, Eui-Joo;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • 제46권3호
    • /
    • pp.161-171
    • /
    • 2022
  • Background: Epilobium hirsutum L. is designated as an endangered plant in South Korea located in Asia, due to the destruction of its habitats through the development of wetlands. Therefore, in this study, in order to find a light condition suitable for the growth and ecophysiological responses of Epilobium hirsutum L., those of this plant under treatment with various light qualities in a smart farm were measured. Results: In order to examine the changes in the physiological and growth responses of Epilobium hirsutum L. according to the light qualities, the treatment with light qualities of the smart farm was carried out using the red light: blue light irradiation time ratios of 1:1, 1:1/2, and 1:1/5 and a red light: blue light: white light irradiation time ratio of 1:1:1. As a result, the ecophysiological responses (difference between leaf temperature and atmospheric temperature, transpiration rate, net photosynthetic rate, intercellular CO2 partial pressure, photosynthetic quantum efficiency) to light qualities appeared differently according to the treatments with light qualities. The increase in the blue light ratio increased the difference between the leaf temperature and the atmospheric temperature and the photosynthetic quantum efficiency and decreased the transpiration rate and the intercellular CO2 partial pressure. On the other hand, the white light treatment increased the transpiration rate and intercellular CO2 partial pressure and decreased the temperature difference between the leaf temperature and the ambient temperature and photosynthetic quantum efficiency. Conclusions: The light condition suitable for the propagation by the stolons, which are the propagules of Epilobium hirsutum L., in the smart farm, is red, blue and white mixed light with high net photosynthetic rates and low difference between leaf temperature and atmospheric temperature.

A Verification Study on the Temperature reduction Effect of Water Mist Injection

  • Kim, Jeong-Ho;Lee, Myung-Hun;Yoon, Yong-Han
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.5-14
    • /
    • 2015
  • Purpose: Recently, according to climate changes, human health is exposed to danger over the world and they influence all fields of human society. Due to these climate changes, humans can be exposed to more frequent and extreme scorching heat and cold wave than the present. As precautions against these urban higher temperature and dryness, diverse methods are being sought. Among them, as measures to form cold islands, the evaporative cooling effect realistic to social and economic conditions was examined. Method: This study was conducted to analyze effects of temperature reduction and cooling according to injection quantity of minute water particles by using a blast sprayer as one of alternatives of alleviation of urban climate changes in outside space in summer. For this, through temperature difference in accordance with the injection quantity per hour of a day, a time zone representing the value of the highest temperature change was analyzed. Also, by analyzing temperature difference according to the injection quantity per daytime insolation, relation of amounts of insolation and evaporation was investigated. Temperature difference in accordance with distances at the highest temperature with the highest value in temperature changes was analyzed. Result: At the study result, about temperature, as injection quantity increase, temperature reduction was significant statistically at the highest temperature with the most insolation. A factor with the highest influence was judged to be the increase of the injection quantity. According to the injection quantity, it was predicted that $3.1^{\circ}C$ temperature reduction of a daily average in case of 0.16L/min, $3.5^{\circ}C$ temperature reduction of a daily average in case of 0.32L/min, and $4.4^{\circ}C$ temperature reduction of a daily average in case of 0.48L/min.

내부 열교환기 부착 R744-R404A용 캐스케이드 냉동시스템의 성능 분석 (Performance analysis of a R744 and R404A cascade refrigeration system with internal heat exchanger)

  • 오후규;손창효
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.38-43
    • /
    • 2012
  • This paper describes an analysis on performance of R744-R404A cascade refrigeration system with internal heat exchanger to optimize the design for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporating and condensing temperature in the R744 low- and R404A high-temperature cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : COP of cascade refrigeration system increases with the increasing of compression efficiency, but decreases with the increasing temperature difference of cascade heat exchanger. Also, the COP increases with the increasing of internal heat exchanger efficiency in high-temperature cycle, but decreases with that in low-temperature cycle. Therefore, internal heat exchanger efficiency, compressor efficiency and temperature difference of cascade heat exchanger on R744-R404A cascade refrigeration system have an effect on the COP of this system.

대류 난방시 실내열환경에 관한 연구 -상하온도차에 대한 온열쾌적감- (The Study on Indoor Thermal Environment during Convection Heating - Thermal Comfort Sensation for Vertical Temperature Differences -)

  • 김동규;금종수
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.215-220
    • /
    • 2005
  • Thermal neutrality is not enough to achieve thermal comfort. The temperature level can be the optimal, and still people may complain. This situation is often explained by the problem of local discomfort. Local discomfort can be caused by radiant asymmetry, local air velocities, too warm and too cold floor temperature and vertical temperature difference. This temperature difference may generate thermal discomfort due to different thermal sensation in different body parts. Therefore, thermal comfort can not be correctly evaluated without considering these differences. This study investigates thermal discomfort sensations of different body parts and its effect on overall thermal sensation and comfort in air-heating room. Experimental results of evaluating thermal discomfort at different body parts in an air-heating room showed that thermal sensation on the shoulder was significantly related to the overall thermal sensation and discomfort. Although it is known that cool-head, warm-foot condition is good for comfort living, cool temperature around the head generated discomfort.

대규모 도시 재개발에 따른 기상환경변화 (The Changes of Meteorological Environment by Urban Development)

  • 김근회;김연희;구해정;김규랑;정현숙
    • 대기
    • /
    • 제24권1호
    • /
    • pp.69-76
    • /
    • 2014
  • Urbanization affects the local thermal environment due to the large scale land use changes. To investigate the weather environment change of large scale urban redevelopment, 9 surface temperature and humidity observations were accomplished at Eunpyeong new town area. The observation period is from March 2007 to February 2010. In the center of development area, the air temperature has increased and relative humidity has decreased, by the changes of the land cover and building construction. In the area where the green zone is maintained, air temperature and relative humidity were not changed significantly. The air temperature and relative humidity for the other development observation stations is decreased and increased, respectively. The relative temperature difference between study area and a neighboring rural location was increased during observation periods. The difference is the highest during winter. The urban-rural minimum temperature difference was increased at development area, which means that urbanization affects increasing of minimum temperature in study area.