Safety Assessment for Emergency Diesel Generator(EDG) Allowed Outage Time(AOT) Extension using Risk-informed (리스크정보를 활용한 비상디젤발전기 허용정지시간 연장시 안전성평가)

  • Lim, Hyuk-Soon;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.118-122
    • /
    • 2010
  • In order to provide the necessary operation flexibility during the Nuclear power operation, the extension of existing allowed outage time(AOT) is needed. The extension of AOT affects the Nuclear power plant safety. The validity of changed technical specification requirements should be proved by the safety assessments. In this paper, we evaluated the extension of emergency diesel generator AOT for a single inoperable emergency diesel generator(EDG) from 3days to 7days, 10days and 14days. Finally, the AOT extension contributes the NPP performances through decreasing the unexpected plant trips, reinforcing maintenance and avoiding risks due to unnecessary operation mode changes when the NPP is under the surveillance tests or maintenance.

Modeling of Hybrid Generation System with Wind Turbine, Diesel Generator and Flywheel Energy Storage System (풍력-디젤-플라이휘일 하이브리드 발전시스템 모델링에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2979-2984
    • /
    • 2013
  • This paper proposes a modeling and controller design method of Flywheel Energy Storage System(FESS) for solving the unstable operation problem in hybrid generation system with wind turbine and diesel generator applied in island area. FESS is considered as a permanent magnetic synchronous machine connected to flywheel because of its efficiency. The controller of FESS is composed of AC/DC/AC back-to-back converter. The AC/DC converter is designed to charge/discharge according to the frequency variation and the DC/AC converter to operate to keep the DC bus voltage constant. The proposed modeling and controller design method of FESS was applied to hybrid generation system with wind turbine and diesel generator. The unstable operation problem owing to wind variations was solved through simulation results.

Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid (독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석)

  • Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

Vibration characteristics and reduction of Diesel Power Plant(DPP) (육상용 중속 디젤엔진 발전기세트의 진동 특성 및 저감)

  • Kim, Won-Hyun;Jung, Kun-Hwa;Lee, Soo-Mok;Ryoo, Young-Seok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.39-40
    • /
    • 2006
  • Diesel power plant(DPP) with the medium speed diesel engine is operated under the very severe condition in aspect of load and operating time as compared with the marine diesel generator set. So, minimized vibration level have to be insured for the more stable operation of engine and generator. The vibration of generator set mainly comes from the resonance between the rigid modes by resilient mount or distortion modes by structural stiffness and the excitation forces of engine. Then, avoidance of resonance with structural modification is generally well known. In this paper, the first order vibration in non-resonance range and local vibration modes were investigated by impact test, response/ODS(operational deflection shape) measurement and 3D finite element analysis for the additional reduction of vibration. The proposed countermeasures were actually applied and their final effects were verified through the in-situ measurement.

  • PDF

Analysis and Evaluation Study on Diesel Generator Engine Operation Signature (디젤발전기 엔진 운전상태 분석 및 평가방법에 대한 연구)

  • Park, J.H.;Choi, K.H.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.82-88
    • /
    • 2009
  • The purpose of this paper is to provide technical background, techniques and actual diesel engine signature analysis evaluation result. Engine signature analysis(ESA) is a process for monitoring the material condition of diesel engine using external sensors, eliminating the need to periodically disassemble the engine. ESA is also used to balanced the engine. Engine balancing is the process of tuning the engine so that all cylinders carry equal load. ESA is a useful tool to non-intrusively determine the operability and performance and assessment of the material condition of internal component of a diesel engine.

  • PDF

Numerical Analysis for Reduction of Fuel Consumption by Improvement of Combustion Condition in a Common Rail Diesel Engine Generator (커먼레일 디젤엔진 발전기의 연소상태 개선에 따른 연비절감을 위한 수치해석)

  • Kim, Seung Chul;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.58-64
    • /
    • 2016
  • The main engine of a vehicle is used an common rail diesel engine for improving the efficiency of the whole load area. However, the generator engines is still used mechanical fuel injection valve drive cams. In addition, most of generator engines is applied a part-load operation of less than 50%. Therefore, diesel engine of vehicle set at 100% load is necessary to readjust in order to perform efficient operation because of part-load operation. In this study, the objective is to report the results of the part-load fuel consumption improvement by injection timing readjust to identify the operational characteristics of a generator engine currently operated in the facilities.

An Experimental Study upon Modeling and Control of Coupled Engine and Generator System (엔진-발전기 시스템 모델링 및 제어특성에 관한 실험적 연구)

  • 송승호;정세종;오정훈;함윤영;최용각;이광희
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.163-169
    • /
    • 2003
  • Modeling of engine-generator system and its control responses are investigated using high performance generator controller. The nonlinear engine is modeled using mean torque production model based on experimental engine map. In case of diesel engine. the amount of injected fief is decided by engine controller depending on the APS(Acceleration Position Sensor) value. An electromechanical generator model contains electrical circuits and moment of inertia. The generator controller maximizes the performance of generator using decoupling and linearized current feedback control. The generator control system consists of 3-phase IGBT inverter and controller board based on 32 bit floating point DSP. Field oriented control algorithm with digital current feedback control at 10kHz sampling enabled high performance torque and speed control of induction machine. Not only the steady state but also the transient state responses can be evaluated through a batch test of the engine generator system. Developed engine and generator modeling and control can be utilized in various applications such as Series Hybrid Electric Vehicle(SHEV), engine-generator for emergency, and other hybrid generation systems.

Diesel Generator-Wind Turbine-Battery Modeling Design and Analysis in Synchronous Condenser mode (Diesel Generator-Wind Turbine-Battery 모델링에 관한 설계 및 분석)

  • Kim, Jae-Kyung;Lee, Ji-Young;Lim, Song-Woon;Kim, Yong-Seon;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1100_1101
    • /
    • 2009
  • 본 논문은 대표적인 신재생에너지인 풍력발전에 관한 연구의 일환으로 RPM-Sim을 이용한 독립형 하이브리드 발전시스템의 시뮬레이션을 분석하였다. 시뮬레이션에서는 Wind Turbine, Diesel Generator, Rotary Converter, Village Load, Dump Load, PCC를 포함한 독립형 하이브리드 발전시스템을 구현하고, 이 하이브리드 시스템은 신재생에너지 자원인 풍력을 최대한 이용한 발전 시스템으로써 디젤 발전기의 사용을 최소한으로 줄여 부하를 충당할 수 있는 시스템을 구현하여 분석했다.

  • PDF

Study on the Improvement of Output Fluctuation from Generator Driven by Large Size-Low Speed Diesel Engine (대형저속 디젤엔진 구동 발전기의 출력변동 개선에 관한 연구)

  • 김영주;전효중;이돈출;이충기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.6-16
    • /
    • 1992
  • Since world-wide oil shock on 1970s, many large size-low speed diesel engines, instead of steam turbines, are used for the industrial electric power generating plants due to their economic advantage of low specific fuel consumption. But it is very important to control their electric power fluctuation problems for the purpose of smooth parallel operation with existing power plants. In this paper the fluctuation problem of KEPCO Nam-cheju No.1 generator driven by diesel ngine(B & W 7K 60MC, 13931x138.5RPM) is investigated with analysis of torsional vibration of which 4th harmonic component is related to its power fluctuation. The problem can be improved by modification of cylinder arrangement and flywheel position in reverse sequence, equalizing the combustion gas pressure of all cylinder and installation of torsional vibration damper enlarged 30%(Je=7287Kg.m$^{2}$) and high quality balancing of generator rotor.