Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen (액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성)

  • Lee, Sang-Hwa;Shin, Woo-Ju;Khan, Umer Amir;Oh, Seok-Ho;Sung, Jae-Kyu;Lee, Bang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

Dielectric Breakdown Behavior of Anodic Oxide Films Formed on Pure Aluminum in Sulfuric Acid and Oxalic Acid Electrolytes

  • Hien Van Pham;Duyoung Kwon;Juseok Kim;Sungmo Moon
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.3
    • /
    • pp.169-179
    • /
    • 2023
  • This work studies dielectric breakdown behavior of AAO (anodic aluminum oxide) films formed on pure aluminum at a constant current density in 5 ~ 20 vol.% sulfuric acid (SA) and 2 ~ 8 wt.% oxalic acid (OA) solutions. It was observed that dielectric breakdown voltage of AAO film with the same thickness increased with increasing concentration of both SA and OA solutions up to 15 vol.% and 6 wt.%, respectively, above which it decreased slightly. The dielectric breakdown resistance of the OA films appeared to be superior to that of SA films. After dielectric breakdown test, cracks and a hole were observed. The crack length increased with increasing SA film thickness but it did not increase with increasing OA film thickness. To explain the reason why shorter cracks formed on the OA films than the SA films after dielectric breakdown test, the generation of tensile stresses at the oxide/metal interface was discussed in relation to porosity of AAO films obtained from cross-sectional morphologies.

Effects of Dielectric Layer Thickness and Electrode Structures on High Xe AC-PDP (High Xe AC PDP에서 전극구조와 유전체 두께에 따른 방전 특성 분석)

  • Heo, Jun;Kim, Yun-Gi;Kim, Dong-Hyun;Lee, Hea-June;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.237-242
    • /
    • 2012
  • In this paper, we investigated effects of ITO electrode geometry and dielectric layer thickness on the discharge Characteristic of AC PDP. As the dielectric thickness is decreased ($30{\sim}12{\mu}m$), firing and sustain voltage is decreased. Luminance and discharge power increase with decreasing dielectric layer thickness because of increasing capacitance between plasma and electrodes. Reactive power decreases with dielectric thickness due to reduced capacitance between sustain electrodes. For the high Xe test panel with small ITO electrode, luminous efficacy as well as luminance increase with decreasing dielectric layer thickness. This result suggest that high power density and small plasma volume is beneficial for high efficacy discharge.

Suppression of Shrinkage Mismatch in Hetero-Laminates Between Different Functional LTCC Materials

  • Seung Kyu Jeon;Zeehoon Park;Hyo-Soon Shin;Dong-Hun Yeo;Sahn Nahm
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • Integrating dielectric materials into LTCC is a convenient method to increase the integration density in electronic circuits. To enable co-firing of the high-k and low-k dielectric LTCC materials in a multi-material hetero-laminate, the shrinkage characteristics of both materials should be similar. Moreover, thermal expansion mismatch between materials during co-firing should be minimized. The alternating stacking of an LTCC with silica filler and that with calcium-zirconate filler was observed to examine the use of the same glass in different LTCCs to minimize the difference in shrinkage and thermal expansion coefficient. For the LTCC of silica filler with a low dielectric constant and that of calcium zirconate filler with a high dielectric constant, the amount of shrinkage was examined through a thermomechanical analysis, and the predicted appropriate fraction of each filler was applied to green sheets by tape casting. The green sheets of different fillers were alternatingly laminated to the thickness of 500 ㎛. As a result of examining the junction, it was observed through SEM that a complete bonding was achieved by constrained sintering in the structure of 'calcium zirconate 50 vol%-silica 30 vol%-calcium zirconate 50 vol%'.

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

A Study on the Dielectric Breakdown Strength and Transparency of Dielectric Layer on the Discharge Electrodes in PDP (PDP에서 방전전극상의 유전층의 절연내력과 투명도에 관한 연구)

  • Lee, Sung-Hyun;Kim, Young-Kee;Chi, Sung-Won;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.379-381
    • /
    • 1997
  • The dielectric layers in AC plasma display panel(AC PDP) are essential to the discharge cell structure, because they protect metal electrodes from sputtering by positive ion and from a sheath of wall charges which are essential to memory function of AC PDP. Furthermore, this layer should be transparent because the visible light must pass through the layer. In this paper, the dielectric breakdown strength and transparency of the dielectric layer on the discharge electrodes are studied. The variables in this test are the dielectric layer thickness, dielectric firing condition, gas pressure, species of gas and so on.

  • PDF

Analysis the Reliability of Multilayer Ceramic Capacitor with inner Ni Electrode under highly Accelerated Life Test Conditions

  • Yoon, Jung-Rag;Lee, Kyung-Min;Lee, Serk-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.5-8
    • /
    • 2009
  • The reliability of multilayer ceramic capacitor with active thin dielectric layer was investigated by highly accelerated life test at various stress condition. The distribution of multilayer ceramic capacitor failure times is plotted as a function of time from Weibull distribution function. According to the test result, voltage acceleration factor is obtained from 2.24 to 2.96. The acceleration by temperature is much higher than other values of active thick dielectric layer. It is clear that median time to failure is affected by the stress voltage for high volumetric efficiency ceramic capacitors with active thin dielectric layer. The degradation under stress of voltage involves electromigration and accumulation of oxygen vacancy at Ni electrode interface of cathode.

Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound (자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성)

  • 송재주;한재홍;송일근;한용희;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

A study on the performance improving of the dielectric test facilities for UHV heavy electric apparatus (초고압 중전기기 절연시험설비 성능개선 연구)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2100-2102
    • /
    • 2005
  • In this Paper, there have been brief review about the important consideration in laboratory planning and designing the dielectric testing facilities for heavy electric apparatus up to 800kV-class in the high voltage testing fields. To improve and reinforce the existing dielectric test facilities in the way of econo-mical and optimal condition, wide investigation and an analysis for a solution, especially overshoot compensation method. have been suggested. With the brief description about those matters in constructing and improving the test facilities, the specification of each facility has been shown in the paper.

  • PDF