• Title/Summary/Keyword: Dielectric Test

Search Result 412, Processing Time 0.029 seconds

Breakdown Characteristics of Dry Air under 362 kV GIB (362 kV GIB 내에서 건조공기의 절연파괴 특성)

  • Han, Ki-Son;Ju, Hyung-Jun;Yoon, Jin-Yul;You, Hong-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

Design and Parametric Study on Discone Antenna for Broadband RF Test Chamber

  • Oh, Soon-Soo;Kim, In-Ryeol;Choi, Dong-Geun;Park, Wook-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.534-538
    • /
    • 2016
  • This paper discusses the characteristics and effects of dielectric inner-supports on discone antenna for broadband RF test chamber, and the verification has been performed by simulation. Several design parameters such as the thickness of the gap support, the position of the side support, and the thickness of the side support has been analyzed. The thickness of the gap support affected the reflection coefficient. An effect of the offset of the side support from the center was slight below 3 GHz and significant above 3 GHz. The thickness of the side support did not affect the reflection coefficient or the gain much. The performance of the fabricated discone antenna was in good agreement with the simulated results. This investigation of a dielectric support effects could be used to design a commercial discone antenna for broadband RF test chamber, focusing on electrical performance and mechanical stability.

Field Distribution of the Reverberation Chamber with Flat Diffusers Composed of Multiple Dielectric Materials (다중 유전체로 구성된 평탄형 Diffuser가 부착된 잔향실 내의 전자기장 분포에 관한 연구)

  • Kim, Young-Ryoul;Kim, Hye-Kwang;Rhee, Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.471-477
    • /
    • 2007
  • This paper presents the characteristics of electromagnetic field uniformity in a reverberation chamber with flat diffusers composed of multiple dielectric materials that can be used as an alternative facility for the analysis, test and evaluation of electromagnetic interference and immunity. The field characteristics and the size of the test volume inside the reverberation chamber with the new diffuser of multiple dielectric materials are simulated and analyzed at $2.5{\sim}3$ GHz band. The FDTD method is used to analyze the field characteristics. The field uniformity, polarization characteristics and tolerance are improved by the new diffuser with smaller physical size. The reverberation chamber with flat diffusers composed of multiple dielectric materials shows better electromagnetic performance and larger test volume than normal chamber.

Enhancement of cover-layer surface properties using dielectric protective layer (유전체 보호층을 이용한 NFR 미디어 커버층의 표면 특성 향상)

  • Kim, Jin-Hong;Lim, Jung-Shik;Lee, Jun-Seok;Seo, Jeong-Kyo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Scratches are observed on a polymer cover-layer of near-field recording (NFR) media after a servo test with rotating disc. The scratches are formed by the collision of a solid immersion lens (SIL)-media. One of the possible ways to avoid the scratch problem is to coat a dielectric protective film on the polymer cover-layer which enhances the hardness of the surface. The surface with hard characteristics in the surface reduces the scratch problem in the cover-layer. Not only the mechanical properties but also the optical properties should be controlled. Specifically, the refractive index of the dielectric protective film should be matched with the polymer cover-layer not to lose light at the interface due to the difference of the refractive index. The refractive index of the dielectric film can be tailored by controlling process parameters during sputtering and matched with that of the polymer cover-layer.

  • PDF

Uncertainty Analysis and Compensation of the Cell for Permittivity Measurement of Solid Materials (고체재료의 유전율 측정용 Cell의 불확도 분석과 보상)

  • Kim, Han-Jun;Yu, Kwang-Min;Kang, Jeon-Hong;Han, Sang-Ok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.53-56
    • /
    • 2008
  • The commercial parallel plate electrodes system with guard-ring electrode have been widely used for measurement of dielectric constants of solid materials. And the specification of the electrodes system is about 1 % of measurement uncertainty. This measurement uncertainty is only estimated the error come from mechanical measurements such as the area of the electrodes and the gap between the electrodes except the error come from the air gap between the electrodes and dielectric specimen. Because it is impossible to measure the air gap. This study analyze the total measurement uncertainties of the commercial dielectric constant test cell using 3 kinds of Standard Reference Materials. As a results, the total measurement uncertainty is much bigger than 1 % and the most of the uncertainty can be reduced by compensation of the error values evaluated in this study.

Characterization of low-k dielectric SiOCH film deposited by PECVD for interlayer dielectric (PEDCVD로 증착된 ILD용 저유전 상수 SiOCH 필름의 특성)

  • Choi, Yong-Ho;Kim, Jee-Gyun;Lee, Heon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.144-147
    • /
    • 2003
  • Cu+ ions drift diffusion in formal oxide film and SiOCH film for interlayer dielectric is evaluated. The diffusion is investigated by measuring shift in the flatband voltage of capacitance/voltage measurements on Cu gate capacitors after bias temperature stressing. At a field of 0.2MV/cm and temperature $200^{\circ}C,\;300^{\circ}C,\;400^{\circ}C,\;500^{\circ}C$ for 10min, 30min, 60min. The Cu+ ions drift rate of $SiOCH(k=2.85{\pm}0.03)$ film is considerable lower than termal oxide. As a result of the experiment, SiOCH film is higher than Thermal oxide film for Cu+ drift diffusion resistance. The important conclusion is that SiOCH film will solve a causing reliability problems aganist Cu+ drift diffuion in dielectric materials.

  • PDF

A Study on the Performance Test and Manufacture of the Dielectric Sensor for the Cure Monitoring of the High Temperature Composites (고온 복합재료의 경화 모니터링을 위한 고온 유전센서의 제작 및 성능평가에 관한 연구)

  • 김일영;최진호;이대길
    • Composites Research
    • /
    • v.14 no.1
    • /
    • pp.30-38
    • /
    • 2001
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the on-line cure monitoring during the cure process of the composite materials has become an important research area for the better quality and productivity. In this paper, the dielectric circuit of the Wheatstone bridge type for measuring the dissipation factor during cure of thermsetting resin matrix composite materials was designed and manufactured. Also, the dielectric sensor for the cure monitoring of high temperature cure composites was developed and tested. The residual thermal stresses of the dielectric sensor during high temperature cure were analyzed by the finite element method and its dielectric characteristics at high temperature cure were analyzed by the finite element method and its dielectric characteristics at high temperature were evaluated. The on-line cure monitoring of the BMI(Bismaleimide) resin was performed using the developed Wheatstone bridge type circuit and the high-temperature dielectric sensor.

  • PDF

Effect of nanofillers on the dielectric properties of epoxy nanocomposites

  • Wang, Q.;Chen, G.
    • Advances in materials Research
    • /
    • v.1 no.1
    • /
    • pp.93-107
    • /
    • 2012
  • Epoxy resin is widely used in high voltage apparatus as insulation. Fillers are often added to epoxy resin to enhance its mechanical, thermal and chemical properties. The addition of fillers can deteriorate electrical performance. With the new development in nanotechnology, it has been widely anticipated that the combination of nanoparticles with traditional resin systems may create nanocomposite materials with enhanced electrical, thermal and mechanical properties. In the present paper we have carried out a comparative study on dielectric properties, space charge and dielectric breakdown behavior of epoxy resin/nanocomposites with nano-fillers of $SiO_2$ and $Al_2O_3$. The epoxy resin (LY556), commonly used in power apparatus was used to investigate the dielectric behavior of epoxy resin/nanocomposites with different filler concentrations. The epoxy resin/nanocomposite thin film samples were prepared and tests were carried out to measure their dielectric permittivity and tan delta value in a frequency range of 1 Hz - 1 MHz. The space charge behaviors were also observed by using the pulse electroacoustic (PEA) technique. In addition, traditional epoxy resin/microcomposites were also prepared and tested and the test results were compared with those obtained from epoxy resin/nanocomposites.

Electric Field Analysis and Removal Characteristics of Escherichia Coli for Water Discharge Tube with Globular SiO$_2$ (구형 SiO$_2$를 갖는 수방전관의 전계 해석 및 대장균 제거 특성)

  • 이동훈
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • This paper shows the simulation of electric field distribution and removal characteristics of Escherichia coli for water discharge tube with globular $SiO_2$. At the experiments of the removing Escherichia coli used the discharge tube with globular dielectric($SiO_2$), because the electric field is increased when applied voltage is increased, the removed ratio of Escherichia coli was related with increasing of applied voltage. When a passing number of test water in water discharge tube is increased, the removed ratio of Escherichia coli is increased because passing number of territory with electric field is increased. When diameter of globular dielectric($SiO_2$) is increased, the removed time of Escherichia coli was decreased because electric field for dielectric polarization of globular dielectric($SiO_2$) was increased. Also, the removed ratio of Escherichia coli of the water discharge tube with globular dielectric($SiO_2$) was measured higher than the removal ratio of the discharge tube without globular dielectric($SiO_2$)

The Prototype Development of an Engine Oil Deterioration Sensor Installed Inside an Oil Filter (오일필터 일체형 엔진오일퇴화감지센서 시작품 개발 I)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.24 no.2
    • /
    • pp.82-89
    • /
    • 2008
  • The purpose of this study is to develop the proto type sensor installed inside an oil filter in order to detect oil deterioration level. The sensor is made up with two concentric cylinders with constant gap in between and a filter element inside the central area. The size will be designed as similar as real oil filters. The sensor will be tested on a test rig, which is circulating engine oil, with the same size of an oil filter adapting housing as real engines'. It will be measured the capacitance of a sample engine oil, then be able to be gotten the dielectric constant. The changes in the dielectric constant could be correlated with the engine oil deterioration level if the sensor development would be completed. In this paper, it will be shown the test results carrying out under variable temperature conditions at atmosphere pressure.