• 제목/요약/키워드: Dielectric Test

검색결과 412건 처리시간 0.028초

전기절연유의 열화진단을 위한 정전용량 센서개발 (Development of Capacitive Sensor for the Diagnosis of Electrical Insulating Oil)

  • 최남호;김한준;김주한;김호수;한상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1609-1611
    • /
    • 2003
  • This paper presents the results on the development of capacitive sensor for the diagnosis of electrical insulating oil, widely used for power transformer. To survey the dielectric properties of the new and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate the operational and the hysteresis characteristics of the sensor, we constructed a test chamber, including dielectric property measuring system. Through the results we could confirm the superior characteristics of the newly developed sensor.

  • PDF

TiO2 또는 MgO 첨가에 따른 마이크로 유전격벽방전 셀의 방전특성 연구 (A Study on the Discharge Characteristics of Micro Dielectric Barrier Discharge Cells by Adding TiO2 or MgO Powder)

  • 한창욱;위성석;이돈규
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1587-1591
    • /
    • 2015
  • For a higher definition discharge cell, the method of high speed addressing is necessary. In order to modify the surface charges, the liquefied $TiO_2$ or MgO powder is added on MgO layer in front glass and on the phosphor in rear glass in micro barrier discharge. Both the electro-optical properties and the discharge time lag characteristics are measured from 4 inch. test panel, such as the discharge voltage, current, luminance, luminous efficacy and discharge time lag. As the results, the statistic time lag is improved by about 40 %.

가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가 (Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT))

  • 문진철;박형기;최충석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.

가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가 (Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings)

  • 조한구;김인성;안명상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

800kV, 50kA 차단기의 전절연 검증을 위한 시험방법 검토 (Review about test method for the full-insulation verification of circuit breaker rated on 800kV, 50kA)

  • 박승재;서윤택;윤학동;김용식;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2005
  • In case of dead-tank circuit breaker with the earthed enclosure, the dielectric performance for phase to ground should be verified under the hot-gas condition produced by the current interruption. This test condition is required in breaking test duties with the rated short-circuit current and rated voltage. And, KERI has completed the reinforcement of the synthetic testing facilities and these facilities have the testing capacity which enables the full-pole testing for 800kV circuit breaker by adopting the series voltage injection method. So, this paper introduced the test circuit and procedures about the full-pole and the multi-part testing method which was devised to estimate the full -insulation of phase-to-ground for the multi-pole and dead-tank circuit breaker.

  • PDF

순환수 펌프용 고압전동기 고정자 권선의 절연내력 평가 (Estimation of Dielectric Strength in High Voltage Motor Stator Windings for Circulating Water Pump)

  • 김희동;공태식;박태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1191-1192
    • /
    • 2015
  • To assess the deterioration condition of stator insulation, diagnostic and overpotential tests were performed on two high voltage(HV) motors for circulating water pump (CWP). Following the long term rewinding program, the diagnostic test was performed on two motors during the planning maintenance period. After completing the diagnostic test, overpotential test was done on the stator windings of HV motors. During the overpotential test, the No. 1 and No. 2 of HV motors failed at 8.8 kV and 7.9 kV, respectively. Stator windings of two HV motors had deteriorated significantly.

  • PDF

직류내전압 시험이 전력케이블(CV) 절연체에 미치는 영향연구 (A Study on the DC Voltage Withstand test for the Ageing of XLPE Power Cable)

  • 이준;임용배;김종서
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.613-616
    • /
    • 1999
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction, insulation breakdown, dielectric character and so on. when apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA), It is analysis to take shape space charge under AC and DC, clear up the point at issue for DC withstand test impressing

  • PDF

A Study on the Insulation Characteristics of Epoxy Composites Using Electric Field Simulation

  • Lee, Deok-Jin
    • 한국컴퓨터정보학회논문지
    • /
    • 제26권2호
    • /
    • pp.53-60
    • /
    • 2021
  • 본 논문에서는 전기 전자부품 및 기구의 절연재료로 널리 적용되고 있는 에폭시 복합재료의 절연 특성 및 신뢰도를 파악하고자 한다. 이를 위해 경제적, 기계적 요인에 의해 필수적으로 첨가되어야 하는 충진재의 분포에 따른 전계 변화를 예측하기 위하여 전계해석 시뮬레이터를 이용하여 그 결과를 확인하였다. 또한 직류 전압 인가 조건하에서 주변 온도 변화 및 충진재 분포에 따른 절연파괴시험을 수행하였고 그 변화를 관찰하였다. 시편은 에폭시 수지에 충진재를 0, 50, 100[phr] 첨가하여 3종류가 제작되었으며 모든 시편의 경우에서 온도가 증가함에 따라 절연파괴강도가 저하됨을 확인하였다. 시뮬레이션 결과 및 실제 절연강도시험 결과를 비교 고찰하여 전기 기구의 절연설계에 필요한 기술적 적용 가능성을 확인하였다.

FOWLP 적용을 위한 Cu 재배선과 WPR 절연층 계면의 정량적 계면접착에너지 측정방법 비교 평가 (Comparison of Quantitative Interfacial Adhesion Energy Measurement Method between Copper RDL and WPR Dielectric Interface for FOWLP Applications)

  • 김가희;이진아;박세훈;강수민;김택수;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제25권2호
    • /
    • pp.41-48
    • /
    • 2018
  • Fan-out wafer level packaging (FOWLP) 적용을 위한 최적의 Cu 재배선 계면접착에너지 측정방법을 도출하기 위해, 전기도금 Cu 박막과 WPR 절연층 계면의 정량적 계면접착에너지를 $90^{\circ}$ 필 테스트, 4점 굽힘 시험법, double cantilever beam (DCB) 측정법을 통해 비교 평가 하였다. 측정 결과, 세 가지 측정법 모두 배선 및 패키징 공정 후 박리가 일어나지 않는 산업체 통용 기준인 $5J/m^2$보다 높게 측정되었다. 또한, DCB, 4점 굽힘 시험법, $90^{\circ}$ 필 테스트 순으로 계면접착에너지가 증가하는 거동을 보였는데, 이는 계면파괴역학 이론에 의해 위상각 증가에 따라 이종재료 계면균열 선단의 전단응력성분 증가에 따른 소성변형에너지 및 계면 거칠기 증가 효과에 의한 것으로 설명이 가능하다. FOWLP 재배선에 대한 최적의 계면접착에너지 도출을 위해서는 시편제작 공정, 위상각 차이, 정량적 측정 정확도 및 결합력 크기 등을 고려하여 4점 굽힘 시험법 또는 DCB 측정법을 적절히 혼용 사용하는 것이 타당한 것으로 판단된다.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.