• 제목/요약/키워드: Dielectric Test

검색결과 412건 처리시간 0.023초

단자속양자 회로 측정프로브의 특성 분석을 위한 시뮬레이션 (Simulation for characterization of high speed probe for measurement of single flux quantum circuits)

  • 김상문;김영환;최종현;조운조;윤기현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.11-15
    • /
    • 2002
  • High speed probe for measurement of sin91e flux quantum circuits is comprised of coaxial cables and microstrip lines in order to carry high speed signals without loss. For the impedance matching between coaxial cable and microstrip line, we have determined the dimension of the microstrip line with 50${\Omega}$ impedance by simulation and then have investigated the effect of line width and cross-sectional shape of signal line, dielectric material, thickness of soldering lead at the coaxial-to-microstrip transition Point, and the an91c between dielectric material and end part of the signal line on the characteristics of signal transmission of the microstrip line. From the simulation, we have found that these all parameter's had influenced on the characteristic of signal transmission on the microstrip line and should be reflected in fabricating high speed probe, We have also determined the dimension of coplanar waveguide to fabricate testing sample for performance test of high speed probe.

Fluorocarbon의 전기적 특성연구 (A study on the electrical characteristics of the fluorocarbon)

  • 허창수;조한구
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.217-223
    • /
    • 1995
  • In this paper, we investigated physical properties and electrical characteristics of the fluorocarbon that used as coolants for large power gas-insulated transformer. Volume resistivity of the fluorocarbon was .rho.=1.87*10$^{15}$ [.ohm.cm] at 1 atm, 27.deg. C. Dielectric constant was 1.86 and decreases as temperature increase. The breakdown voltage at 1 atm was higher than that of transformer oil. The breakdown voltage of fluorocarbon vapor was about 18kV when pressure in a test chamber increases over lkg/cm$^{2}$. When fluorocarbon was mixed with SF$_{6}$ gas, breakdown voltage of the mixed was higher than that of fluorocarbon. Then fluorocarbon leads to increase over 4kg/cm$^{2}$ in pressure as temperature increase. Therefore, when a gas-insulated transformer is manufactured, the design must be taken into consideration a high-pressure.

  • PDF

저밀도 폴리에틸렌 필림의 결정화도 및 전기적 특성 (The crystallinity and electrical characteristics of low density polyetylene thin film)

  • 윤중락;권정열;이헌용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.164-168
    • /
    • 1996
  • The relation between crystallinity and thermal history in low density polyethylene thin films and their effect on electric conduction phenomena and dielectric breakdown was studied. The low density polythylene thin films obtained by the solution growth method heat-treated at 140[$^{\circ}C$] for 2 h and subsequently cooling to various ways. The degree of crystallinity was estimated by the X-ray diffraction measurement for the specimen of slowly cooling, ICE quenching and liquid nitrogen quenching. The result shows that the crystallinity decreases become faster as the cooling speed increased, and that conduction phenomenon is governed by the space charge limited current in high field. It was found that the dielectric breakdown field increases with an increase in cooling speed and test number in self-healing breakdown method.

  • PDF

세라믹 코팅 Al 부스바의 전기적 특성 연구 (Study on Electrical Properties of Ceramic Coated Al Bus Bar)

  • 백승명;곽민환;곽동순
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1647-1650
    • /
    • 2017
  • Bus bars are used in place of cables because they can carry more electrical energy with the same volume of conductors. This paper deals with the electrical properties of ceramic coating material for busbars. A ceramic coated samples were prepared for the electrical properties test. There are two types of samples. One is a sample without degradation, and the other is a sample degraded for 30 days. Four electrical properties tests were carried out in accordance with domestic standards. Four electrical characteristics tests are AC dielectric breakdown, V-t, lighting impulse dielectric breakdown, and discharge arc. Both samples showed excellent electrical properties, and the ceramic coating material is very good insulating materials for bus bar.

레이더를 이용한 콘크리트 교량의 바닥판 상태평가 (Condition Evaluation of Concrete Bridge Decks using CPR)

  • 서진원;이지영;이일용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권4호
    • /
    • pp.101-107
    • /
    • 2000
  • In this study, the Ground Penetrating Radar(GPR) was tested to evaluate the condition of concrete decks. Test results obtained by CPR were compared with values measured from drilled cores and damage mapping by the visual survey. It is shown that GPR can provide highly accurate measurements of layer properties of concrete decks and can map areas of deterioration in bridge decks by dielectric constants. The deck condition can be grouped into categories of "good" or "distressed". The ground penetrating radar data shows promise for producing rapid and accurate condition assessment for bridge decks. And these data can be used to evaluate highway bridge condition and make cost-effective bridge deck rehabilitation by accurately estimating the quantity of deteriorated concrete.

  • PDF

수분열화에 의한 에폭시절연재료의 표면특성에 관한 연구 (A Study on the Surface Properties of Epoxy Insulator by Water Degradation)

  • 임경범;이백수;김종택;정무영;황명환;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1998
  • In examining application of polymer as electrical insulators, it is very important to perform accelerated aging test substituted the process which polymer insulator is degraded for long-time by the process of short-time. The purpose of this paper is to examine the properties of water degradation which affect on the efficiency of epoxy insulator. To do this, the surface properties on epoxy insulating material have been investigated after long-time accelerated degradation in boiling water condition. The experimental results showed the contact angle and surface resistivity after treatment to decrease the sample of water treatment. In dielectric properties, dielectric constant was increased by the aging development with water treatments.

  • PDF

몰드변압기용 에폭시 수지의 열 열화 특성에 관한 연구 (Study on the Thermal Degradation Properties of Epoxy Resin for the Cast Resin Transformer)

  • 남기동;정중일;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1572-1574
    • /
    • 2000
  • In this paper, study on the properties of the thermal degradated epoxy resin which is used in cast resin transformer is performed to investigate the problems of the decreasing insulation characteristics and crack in the cast resin transformer. In the test, contact angle, weight loss, surface resistivity and relative dielectric constant are measured. As the results of the above measurements, the epoxy resin has increased to 150$^{\circ}C$ in the contact angle and surface resistivity but at the above 150$^{\circ}C$ the values have decreased. The relative dielectric constants have increased in the thermal treated samples with the degradation temperature. Consequently, the insulation properties of the epoxy resin which is used in cast resin transformer have increased by the 150$^{\circ}C$ but decreased in the above 150$^{\circ}C$.

  • PDF

방전처리에 따른 Poly(ethylene terephthalate) 필름의 표면특성에 관한 연구 (A Study on the Surface Properties of Poly(ethylene terephthalate) films by Discharge Treatment)

  • 임경범;이백수;이상희;황명환;박구범;박종관;김영일;임헌찬;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1587-1589
    • /
    • 2000
  • In this paper the weight loss, surface potential decay, surface resistivity and dielectric constant are measured to investigate the surface properties, insulation characteristic changes of PET film according to the discharge treatment. As a result of the test, up to the 10[min] the surface potential decay and surface resistivity have increased. Also, from the result of dielectric constant has decreased. On the other hand, the insulation characteristic of PET film have decreased after 10[min] in the discharge treatment.

  • PDF

Thermal stabilityof fluorine doped silicon oxide films

  • Lee, Seog-Heong;Yoo, Jae-Yoon;Park, Jong-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제2권1호
    • /
    • pp.25-31
    • /
    • 1998
  • The reliability of fluorine doped silicon oxide (SiOF) films for intermetal dielectrics in multilevel interconnections of ultra-large scale integrated circuits (ULSIs) is investigated. SiOF films were deposited by electron cyclotron resonance plasma-enhanced chemical vapor deposition (ECRPECVD) using H-free source gases, i.e., SiF4 and O2. The effect of post plasma treatment on the moisture absorption and dielectric properties of SiOF films was carried out I terms of air exposure time, The reliability test of Cu/TiN/SiOF/Fi specimen was carried out in terms of temperature by rapid thermal annealing (RTA) in N2 ambient. After O2 plasma treatment,, no appreciable peak directly related to moisture absorption was detected. The capacitance-voltage (C-V) characteristics of the O2 plasma treated SiOF film showed that the film remained to hold the sound dielectric properties even after boiling treatment. The Cu/TiN/SiOF/Si system was found to be reliable up to $600^{\circ}C$.

변압기 절연물의 열화에 따른 화화적 특성 (Chemical Characteristics of Transformer Insulations by the Thermal Aging)

  • 김재훈;이원영;이병성;이세현;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1912-1914
    • /
    • 2005
  • The electrical, chemical and mechanical characteristics in transformer insulations are changed due to thermal stress. It is known that characteristics of transformer insulations is deteriorated such as decrease of dielectric strength, deterioration of dielectric constant and tensile strength of paper as transformer oil and paper are aged by thermal stress. Furthermore, chemical characteristics of them are deteriorated as like increment of moisture contents and dissolved by-products in oil, etc. In this paper we have been investigated chemical characteristics of transformer by accelerated thermal aging. For this working we have made experimental test cell and aged at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used Karl-Fisher titration method and high performance liquid chromatography (HPLC).

  • PDF